• 제목/요약/키워드: Blue Tooth

검색결과 132건 처리시간 0.023초

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

WPS와 장갑 장치 기반의 동적 제스처 인식기의 구현 (An Implementation of Dynamic Gesture Recognizer Based on WPS and Data Glove)

  • 김정현;노용완;홍광석
    • 정보처리학회논문지B
    • /
    • 제13B권5호
    • /
    • pp.561-568
    • /
    • 2006
  • 차세대 PC를 위한 WPS(Wearable Personal Station)는 정보 처리 및 네트워크 기능을 포함하며 새로운 정보의 획득에 있어 공간적 한계성을 극복할 수 있는 '유비쿼터스 컴퓨팅'의 핵심 단말기로 정의할 수 있다. 기존의 유선 통신 모듈을 이용한 데스크톱 PC 기반의 제스처 인식기는 영상 또는 장갑 장치로부터 사용자의 의미 있는 동적 제스처 데이터를 획득함에 있어 공간상의 제약성 및 이동상의 한계성, 배경 및 음영조건의 변화에 따른 인식 성능의 변화 등 몇 가지 제약사항을 가지고 있다. 따라서 본 논문에서는 이러한 문제점들을 극복하고 해결하고자 제스처 입력모듈을 차세대 PC 플랫폼 기반의 유비쿼터스 환경으로 확대, 적용시켜 제스처 데이터 입력 모듈로부터 새로운 정보의 획득에 있어 한계성을 극복하고 효율적인 데이터 획득 방안을 제시한다 또한 퍼지 알고리즘과 신경망 이론을 이용하여 독립적인 제스처 인식 시스템을 구현하고 개별 시스템의 성능을 비교, 분석함으로써 차세대 PC를 위한 보다 효율적이며 합리적인 제스처 인식 시스템을 제안한다. 제안된 제스처 인식시스템은 동적인 손의 움직임을 입력데이터로 처리하는 제스처 입력모듈과 입력된 데이터로부터 의미 있는 제스처를 분리하기 위한 관계형 DBMS모듈, 그리고 인식의 확장성과 연속된 동적 제스처 중에서 의미 있는 제스처를 인식하기 위한 퍼지 인식 모듈 및 신경망 인식 모듈로 구성되어 있다. 30인의 피실험자에 대하여 15회의 반복 실험을 수행하였으며 사용자의 동적 제스처 인식 실험결과 퍼지 제스처 인식 시스템에서는 98.8%, 신경망 제스처 인식시스템에서는 96.7%의 평균 인식률을 도출하였다.형성에도 유의한 영향을 미치는 것을 알 수 있었다. 셋째, 신뢰와는 다르게 서비스품질이 몰입에는 유의한 영향을 미치지 못하는 것으로 나타났다. 그러나 이러한 직접적인 영향이외에 서비스품질은 고객만족을 통하여 간접적으로 몰입에 강한 영향을 미치는 것으로 나타났다. 넷째, 고객만족은 신뢰에 강하게 정(+)의 영향을 미치는 것으로 나타났다. 즉 고객들이 호텔서비스에 만족할수록 직접적으로 호텔에 대한 신뢰와 애착심이 증가하는 것을 알 수 있었고 간접적으로 서비스품질은 고객만족을 통하여 신뢰에 강한 영향을 미치는 것으로 나타났다. 다섯째, 또한 고객만족은 몰입에 강하게 정(+)의 영향을 미치는 것으로 나타났다. 간접적으로 서비스품질은 고객만족을 통하여 몰입에 강한 영향을 미치는 것으로 나타났다.미숙밭, 중점밭, 고원밭, 화산회밭으로 6개 유형으로 분류할 경우 각각의 분포면적은 41.9%, 23.3%, 17.5%, 13.9%, 1.1. 2.2% 이었다. 도시화 및 도로확대 등 다양한 토지이용 및 지형개변으로 과거의 토양정보가 많이 변경되었다. 그래서, 앞으로는 인공위성자료 및 항공사진을 이용하여 빠르고 쉽게 활용할 수 있는 토양조사 방법개발과 기 구축된 토양도의 수정, 보완 작업이 필요한 절실히 요구되고 있는 현실이다.브로 출시에 따른 마케팅 및 고객관리와 관련된 시사점을 논의한다.는 교합면에서 2, 3, 4군이 1군에 비해 변연적합도가 높았으며 (p < 0.05), 인접면과 치은면에서는 군간 유의차를 보이지 않았다 이번 연구를 통하여 복합레진을 간헐적 광중합시킴으로써 변연적합도가 향상될 수 있음을 알 수 있었다.시장에 비해 주가가 비교적 안정적인 수준을 유지해 왔다고 볼