• 제목/요약/키워드: Blowing ratio

검색결과 94건 처리시간 0.027초

Structural Design of High-Rise Building in Toranomon-Azabudai Project (A Block)

  • Kazumasa, Okabe;Kai, Toyama;Takuya, Furuta;Jyunichi, Yamashita;Hiroki, Mukai;Takahiro, Goseki;Shingo, Masuda;Dai, Shimazaki;Yusuke, Miyagi;Yuji, Ozawa
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.157-170
    • /
    • 2022
  • This paper explains about structural planning and structural design of the high-rise building in Toranomon-Azabudai Project (A Block) which is now under construction. The building is about 330 meters high, has 4.2 aspect ratio, and the outline of the building has shallow curve. We adopted seismic response control structure. The building is a steel rigid frame structure with braces, and it has enough stiffness to obtain its primary natural period to be less than about seven seconds, in consideration of wind response, seismic response and inhabitability for the wind shaking. In terms of business continuity plan, the building has a high seismic performance; value of story drift angle shall be 1/150 or less and members of the building remain almost undamaged while or after a large earthquake. Active mass dumper shall be installed at the top of the building to improve inhabitability while strong wind is blowing.

HS-SPME-GC/MS 법을 이용한 PVC벽지 원자재의 TVOC 기여도 평가 (Evaluation of TVOC contribution from Raw materials of PVC wallpaper using the Headspace-SPME-GC/MS)

  • 장미옥;정탁교;정영림;김만구
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.488-495
    • /
    • 2007
  • 본 연구에서는 headspace-solid phase microextraction(HS-SPME)-GC/MS법을 이용하여 PVC 벽지의 원자재에서 방출되는 TVOC를 분석하여 기여도를 평가하였다. 시료로 사용한 원자재는 6종으로 희석제, 안정제, 가소제, 충전제, 발포제와 PVC 레진이다. 각 원자재 시료를 22 mL 바이알에 9 mL씩 취한뒤 $100^{\circ}C$에서 1시간동안 평형을 이룬 다음 $75{\mu}m$ Carboxen-PDMS 화이버로 $25^{\circ}C$에서 1시간 흡착하여 GC/MS로 분석하였다. 정성결과 toluene, ethylbenzene 그리고 xylene과 같은 방향족 화합물과 acetone, methoxyacetone, 2-butanone 등의 케톤류와 nonane, decane, undecane 등의 알켄류가 검출되었다. 그 밖에도 ethanol, butanol 등의 알콜류와 알데히드류 등이 검출되었다. TVOC 방출량은 희석제 $54.20{\mu}g/g$, 안정제 $32.88{\mu}g/g$, 가소제 $0.50{\mu}g/g$, PVC 레진 $0.88{\mu}g/g$, 발포제 $0.22{\mu}g/g$, 충전제가 $0.11{\mu}g/g$로 나타났다. 각 원자재의 TVOC 방출량과 배합비를 고려한 TVOC 기여도는 희석제 0.708, 안정제 0.129, PVC 레진 0.115 순으로 높게 나타났다. 따라서 희석제와 안정제, PVC레진의 질적인 개선을 통해 TVOC 방출량을 줄이는 노력이 필요하다. 또한 본 연구에서 개발한 HS-SPME-GC/MS 방법은 원자재의 TVOC 분석에 유용하게 사용될 것으로 생각된다.

A Review on the Building Wind Impact through On-site Monitoring in Haeundae Marine City: 2021 12th Typhoon OMAIS Case Study

  • Kim, Jongyeong;Kang, Byeonggug;Kwon, Yongju;Lee, Seungbi;Kwon, Soonchul
    • 한국해양공학회지
    • /
    • 제35권6호
    • /
    • pp.414-425
    • /
    • 2021
  • Overcrowding of high-rise buildings in urban zones change the airflow pattern in the surrounding areas. This causes building wind, which adversely affects the wind environment. Building wind can generate more serious social damage under extreme weather conditions such as typhoons. In this study, to analyze the wind speed and wind speed ratio quantitatively, we installed five anemometers in Haeundae, where high-rise buildings are dense, and conducted on-site monitoring in the event of typhoon OMAIS to determine the characteristics of wind over skyscraper towers surround the other buildings. At point M-2, where the strongest wind speed was measured, the maximum average wind speed in 1 min was observed to be 28.99 m/s, which was 1.7 times stronger than that at the ocean observatory, of 17.0 m/s, at the same time. Furthermore, when the wind speed at the ocean observatory was 8.2 m/s, a strong wind speed of 24 m/s was blowing at point M-2, and the wind speed ratio compared to that at the ocean observatory was 2.92. It is judged that winds 2-3 times stronger than those at the surrounding areas can be induced under certain conditions due to the building wind effect. To verify the degree of wind speed, we introduced the Beaufort wind scale. The Beaufort numbers of wind speed data for the ocean observatory were mostly distributed from 2 to 6, and the maximum value was 8; however, for the observation point, values from 9 to 11 were observed. Through this study, it was possible to determine the characteristics of the wind environment in the area around high-rise buildings due to the building wind effect.

실리카 에어로겔을 첨가한 폴리머 폼의 기계적 특성 (Mechanical Behavior of Polymer Foam Reinforced with Silica Aerogel)

  • 안재혁;김정현;김정대;박성균;박강현;이제명
    • 한국해양공학회지
    • /
    • 제31권6호
    • /
    • pp.413-418
    • /
    • 2017
  • In the present study, silica-aerogel-polyurethane foams were synthesized to improve the mechanical characteristics and insulation performance of the polyurethane foam applied to a liquefied natural gas carrier at a cryogenic temperature of $-163^{\circ}C$. A silica-aerogel-polyurethane foam bulk was prepared using a homogenizer by varying the weight ratio of the silica aerogel (0, 1, 3, and 5 wt%), while maintaining the contents of the polyol, isocyanate, and blowing agent constant. Compression tests were performed at room and cryogenic temperatures to compare the mechanical properties of the silica-aerogel polyurethane foams. The internal temperature of the universal testing machine was maintained through the cryogenic chamber. The thermal conductivity of the silica-aerogel-polyurethane foam was measured using a heat flow meter to confirm the insulation performance. In addition, the effect of the silica aerogels on the cells of the polyurethane foam was investigated using FE-SEM and FTIR. From the experimental results, the 1 wt% silica aerogel polyurethane foam showed outstanding mechanical and thermal performances.

고분자 첨가에 의한 콜타르 핏치의 결정성 및 탄소섬유 물성 변화 (Modification of Coal-Tar-Pitch and Carbon Fiber Properties by Polymer Additives)

  • 김정담;윤재민;임연수;김명수
    • 한국재료학회지
    • /
    • 제26권4호
    • /
    • pp.173-181
    • /
    • 2016
  • In order to use coal tar pitch (CTP) as a raw material for carbon fibers, it should have suitable properties such as a narrow range of softening point, suitable viscosity and uniform optical properties. In this study, raw CTP was modified by heat treatment with three types of polymer additives (PS, PET, and PVC) to make a spinnable pitch for carbon fibers. The yield, softening point, C/H ratio, insoluble yield, and meso-phase content of various modified CTPs with polymer additives were analyzed by changing the type of polymer additive and the heat treatment temperature. The purpose of this study was to compare the properties of CTPs modified by polymer addition with those of a commercial CTP. After the pitch spinning, the obtained green fibers were stabilized and carbonized. The properties of the respective fibers were analyzed to compare their uniformity, diameter change, and mechanical properties. Among three polymer additives, PS220 and PET261 pitches were found to be spinnable, but the carbon fibers from PET261 showed mechanical properties comparable with those of a commercial CTP produced by an air-blowing method (OCI284). The CTPs modified with polymer additive had higher ${\beta}$-resin fractions than the CTP with only thermal treatment indicating a beneficial effect of carbon fiber application.

막냉각 홀의 측면 방향 분사각, 확장각 및 주기가 막냉각 효율에 미치는 영향 (Effects of Compound Angle, Diffuser Angle, and Hole Pitch on Film-cooling Effectiveness)

  • 김선민;이기돈;김광용
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.903-913
    • /
    • 2011
  • 본 연구에서는 가스터빈 블레이드의 냉각을 위해 사용되는 막냉각 홀을 대상으로 다양한 형상변수들이 막냉각 효율에 미치는 영향을 평가하기 위한 수치적 연구를 수행하였다. 삼차원 압축성 Reynolds-averaged Navier-Stokes 해석을 수행하였으며, 난류모델로는 shear stress transport 모델이 사용되었다. 해석을 통해 홀의 형상, 측면 방향 분사각, 홀의 주기 및 분사율이 막냉각 효율에 미치는 영향이 평가되었다. 해석결과, 원통형홀의 경우 측면 방향 분사각이 존재할 때 월등히 향상된 막냉각 효율을 보여주었으며, 홴형상 홀의 경우 측면 방향 분사각이 $20^{\circ}{\sim}30^{\circ}$일 때 가장 높은 막냉각 효율을 보여주었다. 또한 홀의 주기의 변화에 따른 성능평가 결과 높은 분사율일 때가 낮은 분사율의 경우보다 홀의 주기에 의존하는 경향을 보였다.

가스터빈 연소실 냉각을 위한 충돌제트/유출냉각기법에서 사각핀 설치에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics in Impingement/Effusion Cooling System with Rectangular Fins for Combustor Liner Cooling)

  • 홍성국;이동호;조형희
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.39-47
    • /
    • 2005
  • The present study has been performed to investigate the influences of rectangular fins on heat transfer in an impingement/effusion cooling system with crossflow. To simulate the impingement/effusion cooling system with initial crossflow, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter. The crossflow passes between the plates, and various rectangular fins are installed on the plates. Reynolds number based on the hole diameter is fixed to 10,000 and the flow rate of crossflow is changed from 0.5 to 1.5 times of that of the impinging jet. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. Also to analyze the flow characteristics, a numerical calculation is performed. When rectangular fins are installed, the flow and heat transfer pattern is changed greatly from the case without fins. In the injection hole region, the jet impinges on effusion plate without deflection and wall jet spreads symmetrically. In the effusion region, the crossflow accelerates due to the decrease of cross-sectional area in the channel. Local heat/mass transfer coefficients are enhanced significantly compared to the case without fins. As the blowing ratio increases, the effect of rectangular fins against the crossflow becomes more significant and then the higher average heat/mass transfer coefficients are obtained than the case without fins. However, the increase of blockage effect gives more pressure loss in the channel.

가스터빈 연소실 냉각을 위한 충돌제트/유출냉각기법에서 사각핀 설치에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics in Impingement/Effusion Cooling System with Rectangular Fins for Combustor Liner Cooling)

  • 홍성국;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.289-296
    • /
    • 2004
  • The present study has been performed to investigate the influences of rectangular fins on heat transfer in an impingement/effusion cooling system with crossflow. To simulate the impingement/effusion cooling system with initial crossflow, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter. The crossflow passes between the plates, and various rectangular fins are installed on the plates. Reynolds number based on the hole diameter is fixed to 10,000 and the flow rate of crossflow is changed from 0.5 to 1.5 times of that of the impinging jet. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. Also to analyze the flow characteristics, a numerical calculation is performed. When rectangular fins are installed, the flow and heat transfer pattern is changed greatly from case without fins. In the injection hole region, the jet impinges on effusion plate without deflection and wall jet spreads symmetrically. In the effusion region, the crossflow accelerates due to the decrease of cross-sectional area in the channel. Local heat/mass transfer coefficients are enhanced significantly compared to case without fins. As the blowing ratio increases, the effect of fins against the crossflow becomes more significant and then the higher average heat/mass transfer coefficients are obtained than the case without fins.

  • PDF

단열 발포 폴리올레핀계 구조체의 특성에 관한 연구 (A Study on the Characteristics of the Adiabatically Expanded Polyolefin Structured Foams)

  • 황준호;김우년;전재호;곽순종;황승상;흥순만
    • 폴리머
    • /
    • 제29권6호
    • /
    • pp.605-612
    • /
    • 2005
  • 폴리올레핀계 공중합체 수지인 polypropylene-polyethylene-(1-butene) 미발포 수지에 부탄 가스를 물리적 발포제로 이용하여 단열 팽창시킨 발포체의 등온 결정화 거동을 DSC(differential scanning calorimeter)와 편광 현미경을 이용하여 고찰하였으며, 얻어진 결과는 Avrami 식을 이용하여 해석하였다. 발포체의 결정화 반감 시간이 미발포체의 결정화 반감 시간보다 짧고 핵 생성 속도 증가에 따른 nucleation density증가 및 구정 성장 속도가 더 빠름이 발견되었는데, 이는 가공 공정 중의 분자량 감소보다는 단열 팽창 과정에서 진행되는 연신 배향 결정화에 의해 결정화 속도가 증가하였기 때문인 것으로 사료된다. 또한, 단열 구조 발포체는 직경 30 $\mu$m 이하의 균일한 closed cell 형태를 나타내고 있음을 SEM 을 이용하여 관찰하였고, 발포체의 물성은 미발포체에 비해 단열성이 크기 때문에 열전도도가 감소하였고 압축강도는 발포비가 증가할수록 감소하는 것을 알 수 있었다.

필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석 (Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position)

  • 박지민;문주현;이형주;이성혁
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.69-76
    • /
    • 2018
  • 본 연구에서는 가스터빈 블레이드의 필름 냉각에서 45도 리브가 있는 냉각채널의 필름 홀 위치가 블레이드의 표면냉각 성능에 미치는 영향을 전산유체해석 기법을 통하여 분석하였다. 또한 냉각채널의 리브 유무의 영향을 동일 분사율에 대해서 고찰하였다. 수치해석 도메인은 3차원으로 구성하였고 상용코드(Fluent ver. 17.0)를 사용하여 정상상태 조건 하에서 수치해석을 진행하였다. 그 결과를 바탕으로 블레이드 표면에서의 냉각효율, 유속, 유선, 압력 계수를 비교 분석하였고 홀 위치의 변화가 리브 구조에 의해 유발되는 이차 유동의 토출에 미치는 영향을 고찰하였다. 수치해석 결과로부터 리브가 설치되어 있는 경우 냉각채널의 내부유동은 상부에서 반시계 방향 및 하부에서 시계 방향의 와류쌍을 형성하는 것을 확인할 수 있었다. 리브가 있는 채널의 경우 리브에 의하여 발생한 와류유동이 홀 출구 부근에서 더 높은 압력 차이를 유발하여 리브가 없는 경우보다 최소 12% 이상의 높은 냉각 효율을 나타냈다. 또한 리브가 있는 채널 중에서 홀이 좌측에 위치한 경우(Rib-Left) 리브에 의하여 발생한 이차 유동이 홀 부근의 벽면에 부딪혀 홀 경사각 방향으로의 유동이 형성되는 것을 확인하였다. 블레이드 표면으로 토출된 냉각기체가 주 유동 경계층 내부에서 머무는 영역이 다른 케이스에 비하여 넓기 때문인 것으로 사료된다. 또한 이 경우 홀 출구 부근에서 가장 큰 압력 계수 차이를 나타내었고 이로 인하여 냉각기체의 토출이 촉진되어 냉각효율이 다소 증가하였다.