• 제목/요약/키워드: Blower Control

검색결과 107건 처리시간 0.028초

객차용 청정시스템 개발 (Development of Amenity-Oriented Air Cleaning System for Railroad Passenger Cabin)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1234-1239
    • /
    • 2006
  • Because the indoors spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

유도 전동기 고속 운정을 위한 순시적 약자속 제어 (Instantaneous Flux Weakening Control for High Speed Induction Machine)

  • 문주영;이학준;유안노;홍찬욱;이정준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2015
  • 팬(fan), 펌프(pump), 블로어(blower), 전기 자동차(electric/hybrid vehicle), 전동차와 같은 다양한 분야에서 3상 전동기의 고속 운전에 대한 요구가 증대되고 있다. 일반적으로 3상 전동기가 정격 속도 이상의 고속에서 운전하기 위해서는 회전자 자속(rotor flux)의 크기를 운전 상황에 따라 감소시키는 약자속(flux weakening) 제어가 필수적이다. 유도 전동기의 회전자 자속 기준 벡터 제어 시의 약자속 운전은 자속 성분 전류의 크기를 제어하여 유도 전동기의 고속 운전을 가능하게 하는데, 이러한 전류 제어 기반의 약자속 제어는 그 구조가 복잡하고, 제어기 이득 선정에 따른 동특성(dynamic)이 영향울 받는 문제점을 가지고 있다. 본 논문에서는 이러한 단점을 개선하기 위한 순시적 약자속 제어 방법을 제안하고 3.7kW 유도 전동기를 이용한 실험을 통하여 제안된 방식의 성능을 검증한다.

  • PDF

항공장비용 환경제어시스템의 운전특성에 관한 실험적 연구 (Experimental Study on the Operating Characteristics of an Environmental Control System for Avionic Equipments)

  • 박형필;강훈;지용남;최희주;변영만;김영진;오광윤;김용찬
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.809-816
    • /
    • 2010
  • 환경제어시스템은 항공전자장비로부터의 열부하를 제거하기 위한 목적으로 설치되어지며, 본 환경제어시스템은 제어변수의 변화에 따라 다양한 운전특성을 나타낸다. 본 연구에서는 냉매 R-124를 작동유체로 하는 증기압축 사이클 방식을 적용한 환경제어시스템을 설계 및 제작하였다. 냉매충전량, 팽창밸브개도, 압축기 및 송풍기 운전회전수와 같은 제어변수의 변화에 따른 환경제어시스템의 성능 및 운전 특성 변화를 실험하였다. 각 제어변수가 시스템에 미치는 영향을 분석하였으며, 최적제어를 위한 방안을 제안하였다.

1kW급 연료전지 평가시스템 개발에 관한 연구 (A study on development of 1kW SOFC test system)

  • 황현석;이상훈;이주영
    • 한국위성정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.24-27
    • /
    • 2016
  • 본 연구에서는 연료전지 중 발전효율이 50% 이상으로 가장 높고 가정용(1~10kW급) 시스템으로 필요성이 높아지고 있는 고체산화물 연료전지(SOFC, Solid Oxide Fuel Cell)에 대한 평가시스템을 설계하여 최적의 평가성능을 구현코자 하였다. 최적의 연료전지 평가시스템을 구현하기 위하여 전처리 및 반응조건 제어를 위한 온도제어모듈, 반응물에 대한 유량제어모듈, 전자부하기 등을 구현하였다. 온도제어모듈은 K형 서머커플을 사용하여 운전온도인 $750^{\circ}C$에서 $1^{\circ}C$이내의 정밀도 구현이 가능토록 설계하였고, 가스의 양이 일정하게 유지하기 위한 가습기 구조를 설계하였으며, 송풍기 및 히터의 정밀제어가 가능하도록 위상제어보드를 설계하여 적용함으로서 목표성능을 구현하였으며, 전자부하기는 방전방식으로 정전압, 정전류, 정저항 모드와 아날로그 입력과 출력모듈에 별도의 DC-DC 컨버터를 사용하여 오류를 최소화하였다. 구현한 평가시스템의 성능을 측정한 결과 스택전압은 80V에서 0.15%, 스택전류는 100A에서 0.1%의 정밀제어가 가능함을 확인하였다.

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제3권2호
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF

비엠 활성수 플랜트의 공정제어기 설계 및 구현 (A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant)

  • 이상윤
    • 융합신호처리학회논문지
    • /
    • 제16권2호
    • /
    • pp.74-82
    • /
    • 2015
  • 본 논문에서는 BM 활성수를 생산하는 BM 활성수 플랜트 공정 제어시스템 모델을 제안하고, 다음과 같은 기능을 가진 BM 활성수 플랜트 공정 제어기를 개발 하였다. 첫 번째 기능으로는 먼저 부로와가 과부하가 걸렸을 때, 과전류 감지기가 동작하여 일정시간 부로와를 정지시킨 후 재 기동 하도록 하였다. 두 번째는 정전시 유도조에서 퇴비투입조로의 순환을 막기 위해 전동밸브가 정전시 자동으로 닫히는 기능을 부가함으로서 볼밸브의 고장으로 인한 퇴비투입조의 누수를 막을 수 있다. 세 번째는 생산된 활성수를 농축조에서 4개의 저장조로 자동으로 이송할 수 있는 기능을 부가하여 활성수 생산량을 자동 관리 하였다. 그리고 BM 활성수 플랜트 공정제어기 신호측정 시험장치를 개발하여 제작한 BM 활성수 플랜트 공정 제어기가 설계한 사양대로 잘 동작하는지 확인 하였다. 본 연구는 BM 활성수 플랜트 공정제어기를 견실한 저가의 시퀀서 제어방식 기반의 공정 제어기를 개발하여 시스템의 안정성과 효율성의 향상 및 운전관리 비용의 절감을 꾀할 수 있으리라 기대된다.

고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구 (A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone)

  • 김수연;김진선;성진호;한방우;김용진;김학준
    • 한국입자에어로졸학회지
    • /
    • 제15권4호
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

유로 변경식 고도하수처리 공정의 최적 제어 알고리즘에 관한 연구 (A Study on the Optimal Control Algorithms for the Advanced Wastewater Treatment Process with Variable Hydrodynamic Flow Patterns)

  • 강성욱;조욱상;허형우
    • 공업화학
    • /
    • 제16권2호
    • /
    • pp.217-225
    • /
    • 2005
  • H사의 유로변경식 고도하수처리 공법의 제어 변수가 DO와 수온 등으로 한정되어 있어 효율성의 만족도를 충족시켜주지 못하는 현재의 상황을 개선하고자 세 가지 개선방향을 설정하여 Simulation을 통한 Operation Data의 분석 및 장치구성과 실험을 통한 최적제어 Logic을 연구하여 이를 다시 S하수처리장에 설치 적용한 결과이다. 본 실험을 통해서 수온과 유량에 근간한 Operation Mode 변경의 최적화와 이를 통한 동력비 절감을 이루었고 암모니아성 질소의 농도에 따른 Operation Mode의 변경에서 일반 Normal Mode와 병행하여 Save Mode를 새로 적용하여 동력비 절감을 이루었다. 또한 DO 값을 송풍량과 수중폭기기의 교반속도에 의해 비례제어하고 유출수의 암모니아 농도에 따라 DO 값을 제어하여 안정적인 질산화를 이루었다. 이러한 결과는 공정효율의 극대화와 운영 및 유지관리비의 절감을 이루었다.

공공하수처리시설에서 에너지 사용현황 및 절감방안 연구 (A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant)

  • 김종락;이가희;유광태;김동윤;이호식
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

쏠라 썬루프를 이용한 주차환기 시스템의 효과에 관한 실험적 연구 (An Experimental Study on the Benefit of Pre-ventilation Using Solar Sunroof)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.89-95
    • /
    • 2014
  • This study presented the benefit of the pre-ventilation using solar sunroof with integrated photovoltaic. Recent year, auto-makers make an effort to enhance the fuel efficiency and moreover to clean the cabin passenger's health. Solar energy, one of the alternative energies, adapted in automotive air handling system, in order to pre-ventilation when vehicle parked under the sun in summer. The power generated by a prototype solar sunroof has been used to run blower in a air handing system. And the solar sunroof was installed in a vehicle, and evaluated to find out benefit of the pre-ventilation. The effect of reducing the cabin temperature about $3^{\circ}C{\sim}10^{\circ}C$ with 20 ~ 40W power generator from solar sunroof were obtained in the pre-ventilation test. This reduced thermal load can lead to the reduction of air-conditioning operation time than that of current car. Moreover, fuel economy may increase as a results of the short use of the air-conditioning time. Additionally, Total Volatile Organic Compounds in the cabin is reduced maximum 80% than that of the current vehicle.