Air Intake Door Control for the High Air Conditioning Performance (인테이크 도어 제어를 이용한 고성능 냉난방 시스템)

  • Park, Dongkyou;Kim, Yongchul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

Ripple Voltage Compensation Instantaneous Follow Controller of Inverter by using Analog Integrator (아날로그 적분기를 이용한 맥동전압 보상형 순시추종 PWM 제어기를 적용한 인버터)

  • 라병훈;이현우;김광태
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • In this paper, it is suggested that instantaneous compensation PWM control for inverter without the smoothing capacitor Therefore, this inverter system has several advantages. It has small volume and low price to manufacture, decrease trouble rate of inverter, and has power factor correction effect because huge smoothing capacitor-less. And it has compact size control circuit to use analog integrator device. It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter.

A Study on the Ventilation Improvement of Diesel Locomotive Engine Load Test Building using Computational Fluid Dynamics (전산유체역학을 이용한 디젤엔진 부하시험장의 환기 개선에 관한 연구)

  • Park Duckshin;Jeong Byungcheol;Cho Youngmin;Park Byunghyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.227-242
    • /
    • 2005
  • The aim of this study is to relieve the poor ventilation problem of the diesel locomotive engine load test building, located in an urban area. This paper evaluates the ventilation performances of the studied load test building based on the temperature measurement experiment and the computational fluid dynamics (CFD) during the engine load test. The temperature rise caused by the radiator blower of the building was turned out to be the main cause of disturbing the thermal conditions of the building. The indoor temperature distributions simulated by Fluent were validated with the temperature measurement results obtained from the studied building. The simulation results indicated that the comfort condition of this building was poor We suggested several remedial changes in the duct structure of this building for the improvement of the comfort conditions. In addition, a prototype drawing combining several improved design options was proposed. and then the simulation of the temperature distribution in the proposed prototype was performed. The result indicated that the indoor thermal condition of this proposed building was improved when compared with that of the current building.

Intelligent Sprayer System using Tree Recognition (과수 인식을 이용한 지능형 방제기 시스템 개발)

  • Hong, Hyung Gil;Woo, Seong Yong;Song, Su Hwan;Oh, Jang Seok;Yun, Haeyong;Seo, Kab Ho;Kwon, Soon Wook;Lee, Ki Yong;Lee, Jang Chang;Cho, Hee Keun
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.2
    • /
    • pp.115-123
    • /
    • 2020
  • Farmers using conventional sprayer system are exposed to pesticide poisoning and soil pollution due to pesticide application. In order to reduce this problem, the effective sprayer system is required. In this paper, we propose development of intelligent sprayer system using tree recognition. This intelligent sprayer system consists of an image recognition module, a remote control, a sprayer system, an air blower, and a control module. It is possible to spray pesticides automatically and manually through remote control using cameras and controls. We conducted a total of four experiments in tree recognition experiment, test of attachment and water sensitive papers, measurement of pesticide consumption, and measurement of worker exposure. The test results showed that the consumption of pesticides could be reduced while giving the same effect as conventional controls.

Development of an equipment preventing overheated in a car using the solar cell

  • Han, Jong-Soo;Seo, Chang-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.938-941
    • /
    • 2003
  • In this paper we develop an equipment which prevents vehicles from overheating their inside due to exposure to direct sunlight in summer. Overheating of inside vehicle may give rise to accidents, for instances, dying from suffocation, the deformation of its internal equipment and the explosion from the cracks of its internal parts etc.. The equipment is operated under no starting engine. We adjust the overheating of the inside vehicle by operating the equipment. This equipment checks the temperature of the inside vehicle using temperature sensor. If the temperature increases more than reference temperature(a condition which can be given by the driver), the equipment will operate until the temperature of the inside decreases to the given temperature. Its power is obtained from solar cell. So the equipment keeps away overheating accidents as well as provides the drivers with optimized condition. And also it increases the ability of original car battery through solar cell.

  • PDF

Effect of Salinity on Dissolved Oxygen Characteristics in an Ejector-Aerator (이젝터-폭기 시스템의 용존산소특성에 미치는 염도의 영향)

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.640-646
    • /
    • 2011
  • Dissolved oxygen (DO) refers to the volume of oxygen that is contained in water, and is a major indicator of water quality. The objective of this paper was to investigate the effect of salinity on the dissolved oxygen characteristics in an ejector-aerator. An experimental aeration system composed of a motor-pump, an ejector, a motor-blower, a set of aeration and recirculation tank and a control panel. The dissolved oxygen concentrations decreased with the water salinity. The volumetric mass transfer coefficient increased with increasing the water salinity.

Three Phase Switched Reluctance Motor for 100W rated Dryer Blower (건조기 팬용 3상 SRM(100W급))

  • Lim Jun-young;Kim Sang-young;Choi Yong-won
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.195-195
    • /
    • 2004
  • Conventional dryer systems use one induction motor to drive drum and fan. However, nowadays, dryer systems are necessary to use extra fan motor for reducing a drying-time. This fan motor should be variable-speed controlled motor to control drying-time according to the volume of clothes. This paper proposes 3-phase SRM(Switched Reluctance Motor) having 12/8 structure for variable-speed fan motor of dryer system.

  • PDF

Development of Amenity-oriented Air Cleaning System for Railroad Passenger Cabin (철도차량용 공기청정시스템 개발)

  • Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Bark;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1288-1292
    • /
    • 2007
  • Because the indoor spaces of the passenger cabin is generally airtight to secure the safety of passengers and enhance the efficiency of the cabin air conditioning performances, the contamination pattern of them are largely similar to that of general indoor spaces. Therefore, continuous supply of outdoor air is required to keep the amenity of indoor space. Heating, ventilation, and air-conditioning (HVAC) system is composed of air cleaning filter, heater and air conditioned, blower and ducts. To achieve the clean indoor environment, an integrated control of each HVAC equipment are required. In this study, we developed the air cleaning system to enhance the amenity of the railroad passenger cabin.

  • PDF

Optimization of Waste Pneumatic Transportation System by Results of Facility Diagnosis (생활폐기물 관로이송시스템의 진단과 최적화 방안)

  • Chung, Won-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.54-57
    • /
    • 2010
  • The purpose of this article is to diagnosis all aspects of waste pneumatic transportation system, in order to provide everyone interested in the subject with a optimal design and management of the system. The results of the analyzed inlet boxes were especially designed for customers' convenience and automatically operation, side air intake, ensure good wear. And key of pipelines were showed design standard as degree of an angle. Also, the system is mostly equipped with automatic control and watch conducted inside the waste collection facilities, and it will cut down excessive manpower and be able to be managed by least trained personnel.

Development of Automatic Lettuce Harvesting System for Plant Factory (식물 공장용 자동 상추 수확 시스템 개발)

  • 조성인;류관희;신동준;장성주
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.629-634
    • /
    • 1998
  • Factory-style plant production system aims to produce the standardized horticultural products with high quality and cleanness. In Korea, researches for year-round leaf vegetables production system are in progress and the most of them are focused on environment control. Automating technologies for harvesting, transporting and grading need to be developed. A lettuce harvesting system applicable to the plant factory was studied. It was composed of an articulated robot with a cutter and a gripper, lettuce feeding conveyor and air blower. Success rate of the developed system was 94.7 %. The system carried out harvesting a lettuce smoothly and the harvesting time was about 6 seconds per lettuce. The results showed a feasibility of robotic lettuce harvesting.

  • PDF