• Title/Summary/Keyword: Blood vessel mimicking phantom

Search Result 2, Processing Time 0.015 seconds

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.

A Study on the Thickness Measurement of Blood Vessel Wall using the Wavelet Transform of Ultrasound RF Signal (초음파 RF 신호의 Wavelet 변환을 이용한 혈관 벽의 두께 측정에 관한 연구)

  • 김재익;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.179-185
    • /
    • 2001
  • 혈관에 발생하는 동맥 경화증은 그 발생 시기와 진행 정도를 예측하기 힘들어 초기 단계의 진단 및 치료가 어렵다. 이러한 이유로 혈관 질병의 진단은 많은 연구자들의 관심 대상이 되어왔고, 현재까지도 그 진단 장치 및 방법에 관한 연구가 활발히 진행되고 있다. 혈관 벽의 두께 측정은 혈관 질병을 진단할 수 있는 대표적인 지표이다. 그러므로 본 연구는 혈관 벽에서 수신되는 초음파 RF(Radio Frequency) 신호를 wavelet 변환하여 두께를 측정할 수 있는 방법을 제안한다. 시뮬레이션 결과를 토대로 두께가 각각 0.53mm, 1.2mm인 고분자 물질을 가지고 두께측정 실험을 행하였다. 기존의 방법인 주파수 스펙트럼법과 제안한 방법인 wavelet 변환법에 의하여 측정된 평균 두께는 0.53mm인 경우 각각 0.670$\pm$0.168mm(79.10%), 0.448$\pm$0.084mm(84.53%)이고, 1.2mm인 경우 각각 0.962$\pm$0.072mm(80.17%), 1.149$\pm$0.066mm(95.15%)이다. In-vitro 실험을 행하기 위하여 한천, gelatin, SiC 결정을 가지고 두께가 0.85mm인 혈관 유사 시편을 제작하였고, 이 시편으로부터 데이터를 획득하여 이를 제안한 방법으로 두께를 측정하였다. 그 결과 제안한 방법으로 측정된 평균 두께는 0.8008$\pm$0.0154mm(94.22%)이다. 결론적으로 wavelet 변환을 통해서 혈관 벽의 두께를 정밀하게 측정할 수 있는 가능성이 있음을 알 수 있다.

  • PDF