• Title/Summary/Keyword: Blood removal

Search Result 282, Processing Time 0.027 seconds

Pseudoaneurysm of the superficial temporal artery after blunt trauma: case report and literature review

  • Kang, Inho;Mo, Young Woong;Jung, Gyu Yong;Shin, Hea Kyeong
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.130-133
    • /
    • 2022
  • An 88-year-old man presented with a left temporal pulsatile mass that developed after blunt trauma. Based on suspicion of hematoma, needle aspiration was performed with the removal of approximately 15 mL of blood. No evident improvement was noted, and active arterial bleeding was observed at the needle puncture site. Doppler ultrasonography revealed a "yin-yang" sign, and the mass was diagnosed as a pseudoaneurysm of the left superficial temporal artery. Under general anesthesia, the superficial temporal artery was ligated and the pseudoaneurysm was removed. Superficial temporal artery pseudoaneurysm is a rare facial tumor that generally occurs after blunt trauma. Due to its rarity, pseudoaneurysms are often misdiagnosed as hematoma. The treatment of choice is excision, although endovascular intervention is a potential treatment option. However, when a pseudoaneurysm is small, conservative treatment can be used.

Effectiveness of a Hockey-Stick Probe to Localize a Catheter Fragment in a Dog

  • Kim, Kitae;Oh, Dayoung;Shin, Dongmin;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.4
    • /
    • pp.173-176
    • /
    • 2022
  • Intravenous catheterization is a common procedure in human and veterinary medicine. Occasionally, a catheter might break within the blood vessel, and the fragment may cause embolization, infections, or other severe complications, and therefore must be removed promptly. For a successful and low-risk removal, the fragment should be localized accurately; however, ultrasound may be challenging to perform on small dogs due to inadequate probes. We report the case of a 2-year-old, 2.6 kg, intact female toy poodle that presented to the veterinary medical center owing to a recent onion intake; the owner requested to induce emesis. A 24 gauge peripheral intravenous catheter was inserted into the cephalic vein prior to the emetic injection. When the clinician removed the catheter, a device breakage was observed. A tourniquet was applied immediately proximal to the elbow. Ultrasonography was performed with a high-frequency small-footprint linear array transducer, also called a hockey-stick probe, to localize the fragment. An additional ultrasound was performed before surgery to confirm the location of the catheter piece, which migrated 5 cm proximally. Afterward, a surgical intervention allowed us to retrieve the fragment. This report highlights the effectiveness of a hockey-stick probe to determine the location of a catheter fragment in small breed dogs.

A Case of Ocular Sparganosis in China: Episode of Migration from Muscle Cone to Subconjunctiva

  • Xinyuan Chen;Yanyuan Fang;Liming Tao;Miao Liu;Kun Liang
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.6
    • /
    • pp.419-421
    • /
    • 2022
  • To improve our understanding of the migration of sparganum in humans, we report a case of ocular sparganosis having the migratory episode from the muscle cone to the subconjunctiva. A 34-year-old woman was admitted to the Hospital of Anhui Medical University (Hefei, China), in December 2019. She presented with conjunctival hemorrhage and recurrent pain in the left eye. A foreign body was found in the muscle cone of the eye. Two months later, a ribbon-like white material was found under the conjunctiva on slit-lamp examination. A long and slender, actively moving parasite was extracted by surgery. The extracted worm was approximately 8 cm long and 2 mm wide. The worm was whitish, wrinkled, ribbon shaped, and had a slightly enlarged scolex. The worm sample was morphologically identified as a plerocercoid larva (sparganum) of the Spirometra tapeworm. Her conjunctival blood suffusion and eye pain ceased within 1 week after operation. She has been in good health without any symptoms during the 2-year follow-up. A case of ocular sparganosis, in which larval worm migrated from the muscle cone to the subconjunctiva is reported from China.

Bowel Obstruction Due to Less-Digestible Pet Food with No Shadowing on Ultrasonography in a Small-Breed Puppy

  • Junyoung Kim;Jihye Choi;Junghee Yoon
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.127-132
    • /
    • 2024
  • A 6-month-old intact female Bichon Frise dog weighing 0.9 kg presented with vomiting, anorexia, and lethargy persisting for 3 days. No remarkable abnormalities were detected on the history or physical examination. Laboratory findings were mostly normal, except for elevated levels of alkaline phosphatase (ALP) and blood urea nitrogen (BUN). Abdominal radiography revealed a fluid-dilated stomach and gas-dilated intestinal loops in the regional areas. Abdominal ultrasonography was performed to investigate the cause of gastrointestinal dilation, which revealed a rectangular, homogeneous, echogenic foreign material with no shadowing in the small intestine, causing mechanical obstruction. Upon further inquiry involving detailed re-take of history with the owner, a history of ingesting dog gum 4 days prior was identified. On surgical enterotomy, the hard pet food was identified and removed from the distal duodenum. Postoperatively, the patient's clinical signs showed complete improvement, with a return to normal appetite. The present case demonstrates that less-digestible, hard pet food, despite showing no shadowing on ultrasonography, can act as a foreign material, causing mechanical intestinal obstruction in a small-breed puppy. Furthermore, surgical removal of these materials is necessary in cases of intestinal obstruction.

Hemodynamic changes associated with a novel concentration of lidocaine HCl for impacted lower third molar surgery

  • Ping, Bushara;Kiattavorncharoen, Sirichai;Durward, Callum;Im, Puthavy;Saengsirinavin, Chavengkiat;Wongsirichat, Natthamet
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.121-128
    • /
    • 2015
  • Background: The authors studied the hemodynamic effect influent by using the novel high concentration of lidocaine HCl for surgical removal impacted lower third molar. The objective of this study was to evaluate the hemodynamic change when using different concentrations of lidocaine in impacted lower third molar surgery. Methods: Split mouth single blind study comprising 31 healthy patients with a mean age of 23 years (range 19-33 years). Subjects had symmetrically impacted lower third molars as observed on panoramic radiograph. Each participant required 2 surgical interventions by the same surgeon with a 3-week washout period washout period. The participants were alternately assigned one of two types of local anesthetic (left or right) for the first surgery, then the other type of anesthetic for the second surgery. One solution was 4% lidocaine with 1:100,000 epinephrine and the other was 2% lidocaine with 1:100,000 epinephrine. A standard IANB with 1.8 ml volume was used. Any requirement for additional anesthetic and patient pain intra-operation was recorded. Post-operatively, patient was instructed to fill in the patient report form for any adverse effect and local anesthetic preference in terms of intra-operative pain. This form was collected at the seven day follow up appointment. Results: In the 4% lidocaine group, the heart rate increased during the first minute post-injection (P < 0.05). However, there was no significant change in arterial blood pressure during the operation. In the 2% lidocaine group, there was a significant increase in arterial blood pressure and heart rate in the first minute following injection for every procedure. When the hemodynamic changes in each group were compared, the 4% lidocaine group had significantly lower arterial blood pressure compared to the 2% lidocaine group following injection. Post-operatively, no adverse effects were observed by the operator and patient in either local anesthetic group. Patients reported less pain intra-operation in the 4% lidocaine group compared with the 2% lidocaine group (P < .05). Conclusions: Our results suggest that a 4% concentration of lidocaine HCl with 1:100,000 epinephrine has better clinical efficacy than 2% lidocaine HCl with 1:100,000 epinephrine when used for surgical extraction of lower third molars. Neither drug had any clinical adverse effects.

Attenuation of Renal Ischemia-Reperfusion Injury by Antioxidant Vitamins in Pigs (돼지의 신장에서 Antioxidant Vitamins에 의한 허혈 및 재관류 손상의 감소에 관한 연구)

  • Kim, Myung-Jin;Lee, Soo-Jin;Park, Chang-Sik;Son, Hwa-Young;Jun, Moo-Hyung;Jeong, Seong-Mok;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.94-98
    • /
    • 2007
  • This study was to investigate the effects of ascorbic acid and alpha-tocopherol on the attenuation of renal ischemia-reperfusion (IR) injury in pigs. Ten pigs were subjected to 60 minutes of warm unilateral renal ischemia followed by removal of contralateral kidney and then divided into two groups. Treatment group was performed ascorbic acid and alpha-tocopherol pretreatment 2 days before operation and ascorbic acid with heparin-saline solution irrigation-aspiration. Otherwise, control group used only irrigation-aspiration of heparin-saline solution. Blood samples were collected from these pigs for measurement of serum blood urea nitrogen (BUN) and creatinine values, antioxidant superoxide dismutase (SOD) at pre, day 1, day 3, day 7 and day 14. The kidneys were taken for histopathologic evaluation after euthanasia on postoperative day 14. The levels of BUN were significantly increased in the control group on day 1, day 3 and day 7 (P<0.05). And the level of creatinine was significantly increased in the control group on day 3 (p<0.05). Activity of antioxidant enzymes in plasma revealed significant difference (p<0.05) between control and treatment group at day 14. In histopathologic findings, treatment group was showed less damage than that of control group on the basis of renal tubular damage. It was concluded that ascorbic acid and alpha-tocopherol attenuated renal I/R injury in the pigs.

Quantification of seleno proteins in Korean blood serum using solid phase extraction and affinity chromatography-inductively coupled plasma/mass spectrometry (고체상 추출과 친화 크로마토 그라피-유도결합 플라즈마 질량분석법을 이용한 한국인 혈청에서의 셀레노 단백질 정량)

  • Ahn, Ji-Yun;Kwon, Hyo-Sik;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2014
  • Interferences were removed using anion exchange solid phase extraction (AE SPE) in quantification of selenoproteins in Korean human blood serum with affinity high performance liquid chromatography (AF HPLC)-inductively coupled plasma/mass spectrometry (ICP/MS). The average selenium level obtained for healthy Koreans was $94.3{\pm}2.3ngg^{-1}$ using isotope dilution method. AE SPE was coupled to AF column to separate 3 selenoproteins, glutathione peroxidase GPx, selenoprotein SelP, and selenoalbumin SeAlb. Post column isotope dilution was employed to quantify the proteins. The certified reference material of human blood serum BCR-637 was analyzed to give total selenoprotein concentration of $85.4{\pm}3.4ngg^{-1}$, which agreed well with the reference value of $81{\pm}7ngg^{-1}$. The pooled concentration of GPx, SelP, and SeAlb from healthy Koreans (n=20) was $12.1{\pm}1.4ngg^{-1}$, $57.2{\pm}2.0ngg^{-1}$, and $20.0{\pm}1.9ngg^{-1}$, respectively. The sum of selenoproteins is $89.3ngg^{-1}$, which is about the same as the total selenium concentration of $94.3ngg^{-1}$. The fact suggests that selenium in blood serum is mostly consisted of selenoproteins. After the removal of interference, GPx showed a significant decrease (more than 50%) from $25.0ngg^{-1}$ to $12.1ngg^{-1}$. It was identified that the interference in blood serum was mostly from GPx and the use of AE SPE was proven to be efficient in eliminating Cl and Br that cause interference to GPx.

Quantitative Real-Time PCR of Porcine Parvovirus as a Model Virus for Cleaning Validation of Chromatography during Manufacture of Plasma Derivatives (혈장분획제제 제조공정에서 크로마토그래피 세척 검증을 위한 모델바이러스로서의 Porcine Parvovirus 정량)

  • Kil Tae Gun;Kim Won Jung;Lee Dong Hyuk;Kang Yong;Sung Hark Mo;Yoo Si Hyung;Park Sue-Nie;Kim In Seop
    • Korean Journal of Microbiology
    • /
    • v.41 no.3
    • /
    • pp.216-224
    • /
    • 2005
  • Chromatography has now been used successfully to provide the requisite purity for human plasma-derived biop-harmaceuticals such as coagulation factors and immunoglobulins. Recently, increasing attention has been focused on establishing efficient cleaning procedures to prevent potential contamination by microorganisms as well as carry-over contamination from batch to batch. The purpose of present study was to develop a cleaning validation system for the assurance of virus removal and/or inactivation during chromatography process. In order to establish an assay system for the validation of virus clearance during chromatography cleaning process, a quantitative real-time PCR method for porcine parvovirus(PPV) was developed, since PPV, a model virus for human parvovirus B19, has a high resistance to a range of physico-chemical treatment. Specific primers for amplification of PPV DNA was selected, and PPV DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 1.5 $TCID_{50}/ml$. The established real-time PCR assay was successfully applied to the validation of PPV removal and cleaning during SP-Sepharose cation chromatography for thrombin purification and Q-Sepharose anion chromatography for factor VIII purification. The comparative results obtained by real-time PCR assay and infectivity titrations suggested that the real-time PCR assay could be a useful method for chromatography cleaning validation and that it could have an additive effect on the interpretation and evaluation of virus clearance during the virus removal process.

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

Improvement of Virus Safety of a Human Intravenous Immunoglobulin by Low pH Incubation

  • Kim, In-Seop;Choi, Yong-Woon;Lee, Sung-Rae;Cho, Hang-Bok;Eo, Ho-Gueon;Han, Sang-Woo;Chang, Chong-Eun;Lee, Soung-Min
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.619-627
    • /
    • 2001
  • n order to increase the virus safety of a human intravenous immunoglobulin (IVIg) that was manufactured by a successive process of cold ethanol fractionation, polyethylene glycol precipitation, and pasteurization ($60^{\circ}C$ heat treatment for 10h), a low pH incubation process (pH 3.9 at $25{\circ}C$ for 14 days) was employed as the final step. The efficacy and mechanism of the fraction III cold ethanol fractionation, pasteurization, and low pH treatment steps in the removal and/or inactivation of blood-borne viruses were closely examined. A variety of experimental model viruses for human pathogenic viruses, including the Bovine herpes virus (BHV), Bovine viral diarrhoea virus (BVDV), Murine encephalomyocarditis virus (EMCV), and Porcine parvovirus (PPV), were selected for this study. The mechanism of reduction for the enveloped viruses (BHV and BVDV) during fraction III fractionation was both inactivation and partitioning, however, it was partitioning in the case of the nonenveloped viruses (EMCV and PPV). The log reduction factors achieved during fraction III fractionation were ${\geqq}$6.7 for BHV, ${\geqq}4.7$ for BVDV, 4.5 for EMCV, and 4.4 for PPV. Pasteurization was found to be a robust and effective step in inactivating all the viruses tested. The log reduction factors achieved during the pasteurization process were ${\geqq}7.5$ for BHV, ${\geqq}4.8$ for BVDV, 3.0 for EMCV, and 3.3 for PPV. A low pH incubation was very effective in inactivating the enveloped viruses as well as EMCV. The log reduction factors achieved during low pH incubation were ${\geqq}7.4$ for BHV, ${\geqq}3.9$ for BVDV, 5.2 for EMCV, and 2.0 for PPV. These results indicate that the low pH treatment successfully improved the viral safety of the final products.

  • PDF