• Title/Summary/Keyword: Blood pump

Search Result 215, Processing Time 0.029 seconds

Noise Removal Algorithm for Accurate Mean Arterial Pressure Measurement in Pressurized Oscillometric Method (가압식 오실로메트릭 측정법에서 정확한 평균 동맥압 측정을 위한 노이즈 제거 알고리즘)

  • Joh, In-hee;Lim, Jung-hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.184-187
    • /
    • 2018
  • The most important factor in the prevention and treatment of cerebral infarction is to increase cerebral blood flow. Methods for increasing cerebral blood flow include drug-based methods, the surgery, invasive procedures directly inserting medical devices into the artery(NeuroFloTM) and so on. The noninvasive cerebral blood flow increasing device proposed in this paper can reduce the burden on the patient because the probability of complication is low and the treatment level can be determined according to the blood pressure state of the patient. In implementing such a noninvasive cerebral blood flow increasing device, it is important to measure the accurate mean arterial pressure for provision the appropriate level of treatment for the patient. Therefore, to remove a noise, analog and digital filters were used and algorithm for peak value detection, pump control algorithms and so on were.

  • PDF

Development and Animal Tests of Pneumatic Ventricular Assist Device (공압식 심실보조장치의 개발 및 동물실험)

  • 박영환;김상현
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.247-252
    • /
    • 1997
  • Ten acute and chronic in vivo studies were utilized to develop a pneumatic ventricular assist device (VAD) as a bridge to heart transplantation or a circulatory assist device for patients with end-stage heart disease or poor myocardial funct on after cardiac surgery. Two sizes of blood pump of 70cc for adult patients and 34cc for pediatric patients were implanted in the animals. Ventricle of the blood pump was made from the polyurethaae to enhance antithrombogenecity. The VAD was implanted between the left atrium and the descending aorta. Average flow rate was 2.38 L/min for adult and 0.41 L/min for pediatric VAD at the rate of 60 bum. The duration of support ranged from 1 to 26 hours. The most frequent complication was bleeding. Main causes of death were heart failure and respiratory failure. The device function was good for short term use. Studies to date suggest that, with further refinement, a reliable long term VAD that will have clinical application can be developed.

  • PDF

Effects of Preoperative Combined Antiplatelet Agents on the Postoperative Bleeding that Occurs during Off-pump Coronary Artery Bypass Surgery (무심폐기하 관상동맥우회수술에서 아스피린과 Clopidogrel의 수술 전 병합투여가 수술 후 출혈에 미치는 영향)

  • Choi, Kang-Joo;Seong, Hoo-Sik;Kae, Yoe-Kon
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.605-609
    • /
    • 2008
  • Background: It is well known that preoperative administration of combined antiplatelet agents can have an impact on the postoperative bleeding, the requirement for transfusion and the need for reexploration during on-pump coronary artery bypass surgery. Yet its effects have not been well evaluated in the case of off-pump coronary artery bypass surgery. Material and Method: We performed a retrospective study of nineteen patients who underwent OPCAB from March 2003 to December 2004. All the patients had taken antiplatelet agents until 12 hours before operation. The patients were divided into bo groups as an aspirin group and a combined (aspirin+clopidogrel) group. The perioperative platelet count, the hemoglobin level, the hematocrit, the prothrombin time and the aPTT were compared between both groups. The amount of postoperative bleeding, the transfusion requirement and the need for re-exploration to control bleeding were also compared between both groups. Result: There was no difference of operation time and the intraoperative ACT between the aspirin group and the combined group. The amount of blood loss through the chest tube for 24 hours was not different between the aspirin group $(697{\pm}271mL)$ and the combined group $(944{\pm}432mL)$. The number of patients who received blood transfusion was also not different between both groups. There was no patient who required reexploration for bleeding control in both groups. The perioperative hemoglobin level and hematocrit were also not different between both groups, but the postoperative hemoglobin level and hematocrit were decreased significantly in the group. Conclusion: The Preoperative combined antiplatelet (aspirin+clopidogrel) therapy group was not different from the aspirin group for the amount of postoperative bleeding, the amount of blood transfusion and the need for reexploration during off-pump coronary artery bypass grafting. This subject needs further evaluation because of small population in our study.

Development of an Apparatus for the Determination of In Vitro Metabolic Rate Constants of Volatile Organic Chemicals (휘발성 유기용매의 In vitro 대사속도 측정 장치의 개발)

  • Hwang, In-Young;Lee, Yoon
    • Environmental Analysis Health and Toxicology
    • /
    • v.12 no.3_4
    • /
    • pp.43-54
    • /
    • 1997
  • Species, doses and routes extrapolation can be sucessfully carried out by using a physiologically-based pharmacokinetic (PBPK) approach. And PBPK approach to assess risk of hazardous chemicals is reasonable whatever the exposure scenarios are happened. Both partitioning coefficients of chemical between tissue and blood and enzymatic metabolic rate constants are key parameters to build up the PBPK model. In this study, we tried to estimate in vitro metabolic rate constants using a special apparatus instead to measure the in vivo constants which are used to PBPK simulation since the in vitro tests are less expensive and more convenient than in vivo tests. For the purpose, we designed and tested the new system to measure continuously the headspace concentration of VOC. The newly designed system is composed with a diffusion chamber which generates gaseous substrate, a reaction vessel with a recirculating pump to establish a closed system, an autbmatic sampler from a gas phase, a gas chromatography to analyze the headspace. In addition, a cold water condenser is attached between the reaction vessel and pump to reduce the content of gaseous moisture which interferes with chemical analysis. To validate the newly developed methodology, in vitro metabolic rate constants of trichloroethylene (TCE) as a prototype VOC were estimated by simulating observed results with an ACSL program. The simulated results are consistent to those estimated by the other research groups. This finding suggests that our newly designed closed system may be a useful apparatus to estimate in vitro metabolic rate constants for VOC.

  • PDF

Effect of Postoperative Constrictive Physiology on Early Outcomes after Off-Pump Coronary Artery Bypass Grafting

  • Kim, Jung-Hwan;Hwang, Yoo-Hwa;Youn, Young-Nam;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.22-26
    • /
    • 2013
  • Background: Constrictive pericarditis after coronary artery bypass surgery has been known to affect cardiac output by limiting diastolic ventricular filling. We aimed to assess the influence of postoperative constrictive physiology on the early outcomes of patients undergoing off-pump coronary artery bypass grafting (OPCAB). Materials and Methods: Between January 2008 and July 2011, 903 patients underwent an isolated OPCAB and postoperative transthoracic-echocardiography. The patient cohort was classified into two groups: group A, constrictive physiology and group B, control group without constrictive physiology. Early outcomes were analyzed between the two groups. Results: Of the total 903 patients, group A consisted of 153 patients (16.9%). The amount of blood loss in group A during the postoperative 24 hours was greater than that of group B, but this was not statistically significant (p=0.20). No significant differences were found in the mortality rates (group A, 0.6%; group B, 1.4%; p=0.40) and 30-day major adverse cardiac and cerebrovascular events (MACCEs; group A, 3.3%; group B, 6.1%; p=0.42). Conclusion: Postoperative constrictive physiology does not affect 30-day MACCEs or other major complications after OPCAB. The results of this study suggest that patients with early postoperative constrictive physiology do not need medical or surgical treatment, and that conservative care is sufficient.

A Case of Aggravated Hyperplastic Gastric Polyps after Treatment with Long-term Proton Pump Inhibitors (양성자 펌프 억제제 투여로 악화된 과증식 위용종 1예)

  • Kim, Ho Tae;Park, Jong Wan;Eom, Seok Hyeon;Kwak, Tae Yeung;Hwang, Hong Suk;Kim, Yeung Sung;Kwak, Dong Hyup;Kim, Jung Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.141-144
    • /
    • 2013
  • Hyperplastic gastric polyps (HPPs) are the most common type of gastric polyps. They are assumed to be caused by chronic inflammation and regenerative proliferation, although this has not been clearly investigated yet. Many studies suggested the development of fundic gland polyps and carcinoid during long-term proton pump inhibitor (PPI) therapy, but the relationship between PPIs and HPPs is still unclear. We encountered a patient who showed aggravation of HPPs after long-term use of PPIs. A 58-year-old male patient with liver cirrhosis visited our hospital because of hematemesis. We started PPI medication after confirming esophageal variceal bleeding and duodenal ulcer with blood clot in its base via emergency endoscopy. He took PPIs for three years because of an intractable duodenal ulcer. There was a marked increase in the size of the pre-existing polyps and in the development of new polyps. We presumed that the PPIs caused the aggravation of the HPPs, so we stopped their administration. After five months, the HPPs shrank and the polyps were partially degraded. More prospective studies are needed to investigate the relationship between HPPs and PPIs.

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Effects of Antihypertensive Diets Mainly Consisting of Buckwheat, Potato, and Perilla Seed on Blood Pressures and Plasma Lipids in Normotensive and Spontaneously Hypertensive Rats (메밀, 감자, 들깨를 이용한 항고혈압 기능성 식이가 정상혈압쥐 및 본태성고혈압쥐에서 혈압 및 혈장지질에 미치는 영향)

  • 한찬규
    • Journal of Nutrition and Health
    • /
    • v.29 no.10
    • /
    • pp.1087-1095
    • /
    • 1996
  • The study was carried out to investigate a new type of functional foods with hypotensive effect which is critical in the prevention and treatment of hypertension and related circulatory diseases. The experimental diets(A, B, C) were prepared from plant based ingredients such as buckwheat, potato, perilla seed with different ratios formulated as an edible form appropriate for human consumption according to AIN-77 standard. Control group(D) was fed commercial rat chow. Twety-four 15-week-old SDR(Sprague Dawley rats) and twenty-four 20-week-old SHR(spontaneously hypertensive rats), weighing 200g respectively, were assigned to 4 treatments of 6 rats each in a completely randomized design. Blood pressure was measured at 7 day interval by tail-cuff sphygmomanometer using an IITC cuff pump and amplifier. The growth rates of both SHR and SDR were not statistically different in comparions with the control except those of diet B and C in SDR and SHR, respectively(p<0.05). When exprimental diets were fed, systolic blood pressure of SDR and SHR at day 28 had been lowered by 17-20 mmHg(ave. of 19.6mmHg for both strains) compared with the reference pressure at day 0. The levels of HDL-cholesterol were increased, while the levels of LDL-cholesterol consistently decreased in both strains when experimental diets were fed(p<.05). Plasma total cholesterol levels were not different among treatments. Plasma triglyceride levels were higher in control diet(commercial rat chow) due to two times higher fat content of control diet itself(p<.05). Atherogenic indices were lower compared to those of control when the experimental diets were fed in both strains (p,.05). The results suggest that the antihypertensive diets mainly consisting of plant-based ingredients may possibly effective in relieving hypertension as well as circulatory diseases.

  • PDF

Blood Flow and Pressure Evaluation for a Pulsatile Conduit-Shaped Ventricular Assist Device with Structural Characteristic of Conduit Shape (관형의 구조적 특징을 갖춘 박동형 관형 심실보조장치의 혈류, 혈압 평가)

  • Kang, Seong-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1191-1198
    • /
    • 2011
  • The use of a ventricular assist device (VAD) can raise the one-year survival rate without cardiac transplantation from 25% to 52%. However, malfunction of the VAD system causes 6% of VAD patients' deaths, which could possibly be avoided through the development of new VADs in which VAD malfunctions do not affect the patient's heart movement or hemodynamic state. A conventional VAD has an impeller or vane for propelling blood that can allow blood to regurgitate when the propelling force is weaker than the aortic pressure. In this paper, we developed a new pulsatile conduit-shaped VAD that has two valves. This device removes the possibility of blood regurgitation and has a small stationary area even when the pumping force is extremely weak. We estimated the characteristics of the device by measuring the outflow and the pressure of the pump in in-vitro and in-vivo experiments.