• Title/Summary/Keyword: Blood pressure monitoring

Search Result 194, Processing Time 0.025 seconds

The Effects of Karvonen Exercise Prescription in Acute Coronary Artery Disease Patients Reaching Age-Predicted Maximal Heart Rates with Exercise Stress Test

  • Kim, Chul;Kim, Young-Joo
    • Biomedical Science Letters
    • /
    • v.19 no.3
    • /
    • pp.254-260
    • /
    • 2013
  • The purpose of this study was to survey the effects of Karvonen exercise prescription in coronary artery disease patients reaching age-predicted maximal heart rates with the exercise stress test on hemodynamic responses and cardiorespiratory fitness. The subject group was comprised of acute coronary syndrome (ACS) patients, who were divided into the maximal heart rate (MHR) group that included those who completed the test with their heart rates reaching the number of 220-age and the maximal dyspnea (MD) group that included those who could not continue the test due to respiratory difficulty and were asked to stop the test. Both groups had the exercise stress test before and after the experiment. In the exercise stress test before the experiment, the exercise prescription intensity of Karvonen was set at the target heart rates of 50~85% with a six-week exercise monitoring arrangement. As a result, there were no interactive effects in rest heart rate (RHR) according to time and group, but interactive effects were observed in maximal heart rate (MHR) (P=0.000). Both rest systolic blood pressure (RSBP) and rest diastolic blood pressure (RDBP) had no interactive effects according to time and group. Maximal systolic blood pressure (MSBP) showed significant interactive effects according to time and group (P=0.017). Maximal diastolic blood pressure (MDBP) showed no interactive effects according to time and group, while maximal rate pressure product (MRPP) showed significant interactive effects according to time and group (P=0.003). Maximal time (MT) had no interactive effects according to time and group. $VO_{2max}$ and maximal metabolic equivalent (MMET) showed significant interactive effects according to time and group (P=0.000, P=0.002, respectively), whereas maximal respiratory exchange ratio (MRER) and maximal rating of perceived exertion (MRPE) showed no interactive effects according to time and group. The exercise test that was discontinued as the subjects reached the predicted maximal heart rates considering age did not reach the maximal exercise intensity and accordingly showed low exercise effects when applied to Karvonen exercise prescription intensity. That is, the test should keep going by monitoring cardiac events, MRER and MRPE until the heart rates exceed the predicted MHR by up to 10~12 even after the subject reaches the predicted MHR considering age in the exercise stress test.

Implementation of Service Model to Exchange of Biosignal Information based on HL7 Fast Health Interoperability Resources for the hypertensive management (고혈압 관리를 위한 헬스레벨 7 FHIR 기반 생체정보 교환 서비스 모델 구현)

  • Cho, Hune;Won, Ju Ok;Hong, Hae Sook;Kim, Hwa Sun
    • Journal of Internet Computing and Services
    • /
    • v.15 no.3
    • /
    • pp.21-30
    • /
    • 2014
  • Hypertension is one of the major causes of death in the world as it is related with cardiovascular or cerebrovascular disease, so it is needed to provide continuos management for blood pressure. This study selected Health Level 7 Fast Health Interoperability Resources (HL7 FHIR) as a bio-signal data exchange service model that can provide constant blood pressure management in the rapidly growing mobile health care environment. The HL7 FHIR framework developed communicates with the IEEE 11073-10407 Personal Health Device (PHD) protocol through the bluetooth Health Device Profile (HDP) between the manager (smart phone) and the agent (hemomanometer) and acquires information about blood pressure. According to the test results, it performed its tasks successfully including hypertension patients' blood pressure monitoring, management on measured records, generation of document, or transmission of measured information. Because in the actual, clinical environment, it is possible to transmit measured information through the TCP/IP protocol, it will be needed to conduct constant research on it and vitalize it in the field of mobile health care afterwards.

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Effect of the respiratory rate on the pulse pressure variation induced by hemorrhage in anesthetized dogs

  • Dalhae, Kim;Won-Gyun, Son;Donghwi, Shin;Jiyoung, Kim;Inhyung, Lee
    • Journal of Veterinary Science
    • /
    • v.23 no.6
    • /
    • pp.68.1-68.8
    • /
    • 2022
  • Background: Studies on anesthetized dogs regarding pulse pressure variation (PPV) are increasing. The influence of respiratory rate (RR) on PPV, in mechanically ventilated dogs, has not been clearly identified. Objectives: This study evaluated the influence of RR on PPV in mechanically ventilated healthy dogs after hemorrhage. Methods: Five healthy adult Beagle dogs were premedicated with intravenous (IV) acepromazine (0.01 mg/kg). Anesthesia was induced with alfaxalone (3 mg/kg IV) and maintained with isoflurane in 100% oxygen. The right dorsal pedal artery was cannulated with a 22-gauge catheter for blood removal, and the left dorsal pedal artery was cannulated and connected to a transducer system for arterial blood pressure monitoring. The PPV was automatically calculated using a multi-parameter monitor and recorded. Hemorrhage was induced by withdrawing 30% of blood (24 mL/kg) over 30 min. Mechanical ventilation was provided with a tidal volume of 10 mL/kg and a 1:2 inspiration-to-expiration ratio at an initial RR of 15 breaths/min (baseline). Thereafter, RR was changed to 20, 30, and 40 breaths/min according to the casting lots, and the PPV was recorded at each RR. After data collection, the blood was transfused at a rate of 10 mL/kg/h, and the PPV was recorded at the baseline ventilator setting. Results: The data of PPV were analyzed using the Friedman test followed by the Wilcoxon signed-rank test (p < 0.05). Hemorrhage significantly increased PPV from 11% to 25% at 15 breaths/min. An increase in RR significantly decreased PPV from 25 (baseline) to 17%, 10%, and 10% at 20, 30, and 40 breaths/min, respectively (all p < 0.05). Conclusions: The PPV is a dynamic parameter that can predict a dog's hemorrhagic condition, but PPV can be decreased in dogs under high RR. Therefore, careful interpretation may be required when using the PPV parameter particularly in the dogs with hyperventilation.

The Effect of Self-help Programs for Hypertensives in Community Areas (고혈압환자를 위한 자조관리 프로그램의 효과)

  • 박남희
    • Korean Journal of Health Education and Promotion
    • /
    • v.20 no.3
    • /
    • pp.207-219
    • /
    • 2003
  • This study was conducted to identify the effects of the comprehensive nursing aided self-help program for hypertensives. The program educates hypertensives in community areas about blood pressure, self-care, health promoting behaviors, and life satisfaction. For this purpose a one group time series design was used. Sixteen subjects were evaluated from S Community Health center of B city. Self-help programs developed by the author were given to the subjects. The program consisted of group education on hypertension and self-care including blood pressure self-monitoring, recording of self-care activities, and encouraging and reinforcing self-help. The whole program was carried out from October to December in 2002. Data was analyzed by repeated measure ANOVA, and post-hoc Turkey. The results were as follows: There were significant relationships between changes in systolic pressure(F=10.638. P=.000), diastolic pressure(F=6.783. p=.013), self-care(F=13.506. p=.000), and health promoting behavior(F=9.067. p=.001) at the 6th week and the 9th week. There were no significant relationships between changes in life satisfaction at the 6th week or 9th week. From these results, it can be concluded that the self-help program is an effective nursing strategy to promote self-care of hypertensives in community areas.

Wearable and Implantable Sensors for Cardiovascular Monitoring: A Review

  • Jazba Asad;Jawwad Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.171-185
    • /
    • 2023
  • The cardiovascular syndrome is the dominant reason for death and the number of deaths due to this syndrome has greatly increased recently. Regular cardiac monitoring is crucial in controlling heart parameters, particularly for initial examination and precautions. The quantity of cardiac patients is rising each day and it would increase the load of work for doctors/nurses in handling the patients' situation. Hence, it needed a solution that might benefit doctors/nurses in monitoring the improvement of the health condition of patients in real-time and likewise assure decreasing medical treatment expenses. Regular heart monitoring via wireless body area networks (WBANs) including implantable and wearable medical devices is contemplated as a life-changing technique for medical assistance. This article focuses on the latest development in wearable and implantable devices for cardiovascular monitoring. First, we go through the wearable devices for the electrocardiogram (ECG) monitoring. Then, we reviewed the implantable devices for Blood Pressure (BP) monitoring. Subsequently, the evaluation of leading wearable and implantable sensors for heart monitoring mentioned over the previous six years, the current article provides uncertain direction concerning the description of diagnostic effectiveness, thus intending on making discussion in the technical communal to permit aimed at the formation of well-designed techniques. The article is concluded by debating several technical issues in wearable and implantable technology and their possible potential solutions for conquering these challenges.

Efficacy of minimal invasive cardiac output and ScVO2 monitoring during controlled hypotension for double-jaw surgery

  • Kim, Seokkon;Song, Jaegyok;Ji, Sungmi;Kwon, Min A;Nam, Dajeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.6
    • /
    • pp.353-360
    • /
    • 2019
  • Background: Controlled hypotension (CH) provides a better surgical environment and reduces operative time. However, there are some risks related to organ hypoperfusion. The EV1000/FloTrac system can provide continuous cardiac output monitoring without the insertion of pulmonary arterial catheter. The present study investigated the efficacy of this device in double jaw surgery under CH. Methods: We retrospectively reviewed the medical records of patients who underwent double jaw surgery between 2010 and 2015. Patients were administered conventional general anesthesia with desflurane; CH was performed with remifentanil infusion and monitored with an invasive radial arterial pressure monitor or the EV1000/FloTrac system. We allocated the patients into two groups, namely an A-line group and an EV1000 group, according to the monitoring methods used, and the study variables were compared. Results: Eighty-five patients were reviewed. The A-line group reported a higher number of failed CH (P = 0.005). A significant correlation was found between preoperative hemoglobin and intraoperative packed red blood cell transfusion (r = 0.525; P < 0.001). In the EV1000 group, the mean arterial pressure (MAP) was significantly lower 2 h after CH (P = 0.014), and the cardiac index significantly decreased 1 h after CH (P = 0.001) and 2 h after CH (P = 0.007). Moreover, venous oxygen saturation (ScVO2) decreased significantly at both 1 h (P = 0.002) and 2 h after CH (P = 0.029); however, these values were within normal limits. Conclusion: The EV1000 group reported a lower failure rate of CH than the A-line group. However, EV1000/FloTrac monitoring did not present with any specific advantage over the conventional arterial line monitoring when CH was performed with the same protocol and same mean blood pressure. Preoperative anemia treatment will be helpful to decrease intraoperative transfusion. Furthermore, ScVO2 monitoring did not present with sufficient benefits over the risk and cost.

Antihypertensive effect of Chunghyul-dan(Qingxue-dan) on stage 1 hypertensive patients with stroke (중풍환자 1기 고혈압에 청혈단(淸血丹)의 항고혈압 효과)

  • Kim, Lee-Dong;Lee, Sang-Ho;Kim, Eun-Ju;Kim, Tai-Hun;Park, Young-Min;Jung, Dong-Won;Shin, Won-Jun;Jung, Woo-Sang;Bae, Hyung-Sup;Yun, Sang-Pil
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.195-201
    • /
    • 2004
  • Background and Purpose : Hypertension is one of the modifiable risk factors for stroke. Lowering blood pressure is a primary or secondary preventative measure for stroke. This study aims to assess the efficacy of Chunghyul-dan(Qingxue-dan) in stage 1 hypertensive patients who have suffered a stroke by 24 hour ambulatory blood pressure monitoring(24ABPM). Subjects& Methods : We enrolled 40 hospitalized stroke patients with stage 1 hypertension and divided them into 2 groups by stratified randomization; group A took 1200mg of Chunghyul-dan(Qingxue-dan) at 8:00 a.m. for two weeks without changing herbal medicine, and group B was the control group. 28 patients were included in the final analysis(15 in group A. 13 in group B). Blood pressure is monitored from 8:00 am to 7:30 am every 30 minutes for 24 hours. Blood pressure was monitored two times at baseline and again two weeks later. We used 3 parameters for evaluating the efficacy of Chunghyul-dan(Qingxue-dan); The first parameter is change from baseline to two weeks later in blood pressure and pulse rate. The second parameter is the trough/peak ratio(TPR) and smoothness index(SI). The third parameter is antihypertensive rate by antihypertensive efficacy guideline. Results : There is no significant difference in the baseline assessment hetween the two groups. Systolic blood pressure $(141.37{\pm}8.96\;mmHg\;vs\;132.28{\pm}9.46\;mmHg)$ decreased after two weeks of 1200mg(P=0.03) intake of Chunghyul-dan(Qingxue-dan). Systolic TPR and SI was 0.87 and 1.04 in group A. Antihypertensive rate was higher in group A. Conclusion: These results suggest that 1200mg doses of Clunghyul-dan(Qingxue-dan) is an effective antihypertensive agent on stage 1 hypertension patients who have suffered a stroke.

  • PDF

Design of Capacitive Sensors for Blood Vessel Condition Using FEA Simulation; For Developing of an Implantable Telemetry System to Monitoring the Arterial Change (FEA 시뮬레이션을 이용한 혈관 상태 측정용 커패시티브 센서 설계; 체내 동맥 혈관 변화 모니터링이 가능한 이식형 텔레메트리 시스템 개발을 위한)

  • Kang, So Myoung;Lee, Jae Ho;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.11
    • /
    • pp.1280-1287
    • /
    • 2019
  • For developing a wireless implantable device to monitoring the artery variation in real-time. The concept of a special vessel variation measurement capacitive sensor is presented in this paper. The sensor consists of two part; main sensor to measuring the arterial variation, and reference sensor is used to improve the accuracy of the capacitance value variation. Before sensor manufacture, a model of the sensor attached on the artery was designed in 3D to conduct in the FEA simulation to validate the validity and feasibility of the idea. The artery model was designed as layered structures and made of collagenous soft tissues with intima inside, followed by the media and the adventitia. Also, a grease layer was designed in the inner of the arterial wall to imitate the clogged arteries. The simulation was divided into two parts; sensor performance test by changing the diameter of the grease layer, and arterial wall tension test by changing the blood pressure. As the simulation results, the capacitance value measured by the proposed sensor is decreased follow the diameter of the grease increased. Also, large elastic deformation of the arterial wall since changing the blood pressure has been observed.

Evaluation on Clinical Application of Osmotic Pump with Dorzolamide in Normal Dogs

  • Kwon, Yonghwan;Kim, Jury;Kim, Min-Su
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.325-329
    • /
    • 2019
  • This study was designed to compare the effects of continuous release of an anti-glaucoma drug applied by an osmotic pump and by conventional eye drop instillation in normal beagle dogs, by measuring drug concentration in the blood and monitoring intra-ocular pressure (IOP). In group 1, an osmotic pump filled with Trusopt® was implanted subcutaneously over the right eye of each dog and the IOP was measured. In group 2, the right eye of each dog was administered with 2% dorzolamide (Trusopt®, Merck, USA) three times per day. Blood was sampled once per week in all groups. The IOP of the end of this study was 16.7 ± 0.58 mmHg in group 2 and 17.7 ± 2.52 mmHg in group 2. Dorzolamide concentration in blood increased continuously over 4 weeks up to 585.8 ± 79.42 ㎍/L in group 1, and 747.3 ± 27.89 ㎍/L in group 2. We achieved satisfactory results in the osmotic pump group, which had a similar effect on IOP, and low fluctuations in IOP. Therefore, the results of this study should allow osmotic pumps to be consider as an alternative method to eye drops for the effective, safe, and convenient treatment of glaucoma.