• Title/Summary/Keyword: Blood pressure monitor

Search Result 106, Processing Time 0.022 seconds

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

Short Term Weight Control Program of Obese Female College Students through Food Consumption Monitoring Using Mobile Phone Equipped with Camera (비만 여대생을 대상으로 카메라가 장착된 모바일 폰을 이용한 음식섭취 모니터링 강화를 통한 단기간 체중조절)

  • Jung, Eun-Young;Hong, Yang-Hee;Kim, Young-Suk;Kim, Yun-Joo;Chang, Un-Jae
    • Journal of the Korean Dietetic Association
    • /
    • v.16 no.4
    • /
    • pp.369-377
    • /
    • 2010
  • This study was conducted to investigate the effects of food consumption monitoring based on a digital photography method using a mobile phone on food consumption and weight reduction. Eighteen female college students (>30% body fat) participated in the weight control program using a mobile-phone for 4 wks. The energy intake was reduced significantly after 3 wks compared to baseline (P<0.05, baseline: 1,453.0 kcal, 3rd wk: 1,171.1 kcal, 4th wk: 1,130.8 kcal). The subjects lost 2.8 kg of body weight, 1.4% of % body fat, and 1.1 $kg/m^2$ of body mass index (BMI) after 4 wks. There were also significant differences in blood pressure (P<0.001) and serum cholesterol (total cholesterol: P<0.05, LDL-cholesterol: P<0.01) before and after the self-regulated diet program. In this study, the digital photography method using a mobile-phone influenced weight control through trained consumption monitoring, which helps individuals reduce discrepancies between perceived and actual consumption levels. Therefore, effective monitoring by taking food pictures using a mobile-phone can lead individuals to rely more heavily on easy-to-monitor visual cues.

Comparative Study of Brain Protection Effect between Thiopental and Etomidate Using Bispectral Index during Temporary Arterial Occlusion

  • Kim, Tae-Kwan;Park, Ik-Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.497-502
    • /
    • 2011
  • Objective : This study was conducted to compare the effect of etomidate with that of thiopental on brain protection during temporary vessel occlusion, which was measured by burst suppression rate (BSR) with the Bispectral Index (BIS) monitor. Methods : Temporary parent artery occlusion was performed in forty one patients during cerebral aneurysm surgery. They were randomly assigned to one of two groups. General anesthesia was induced and maintained with 1.5-2.5 vol% sevoflurane and 50% $N_2O$. The pharmacological burst suppression (BS) was induced by a bolus injection of thiopental (5 mg/kg, group T) or etomidate (0.3 mg/kg, group E) according to randomization prior to surgery. After administration of drugs, the hemodynamic variables, the onset time of BS, the numerical values of BIS and BSR were recorded at every minutes. Results : There were no significant differences of the demographics, the BIS numbers and the hemodynamic variables prior to injection of drugs. The durations of burst suppression in group E ($11.1{\pm}6.8$ min) were not statistically different from that of group T ($11.1{\pm}5.6$ min) and nearly same pattern of burst suppression were shown in both groups. More phenylephrine was required to maintain normal blood pressure in the group T. Conclusion : Thiopental and etomidate have same duration and a similar magnitude of burst suppression with conventional doses during temporary arterial occlusion. These findings suggest that additional administration of either drug is needed to ensure the BS when the temporary occlusion time exceed more than 11 minutes. Etomidate can be a safer substitute for thiopental in aneurysm surgery.

Design and Implementation of a Ubiquitous Health Care System based on Sensor Network (센서네트워크에 기반한 유비쿼터스 헬스케어 시스템의 설계 및 구현)

  • Kim, Jeong-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.1
    • /
    • pp.143-151
    • /
    • 2008
  • In this paper, we have implemented a ubiquitous healthcare system that can measure and check human's health in anytime and anywhere. The implemented prototype are composed of both front-end and back-end. The front-end have several groups: environment sensor group such as temperature, humidity, photo, voice sensor, health sensor group such as blood pressure, heart beat, electrocardiogram, spo2 sensor, gateway for wired/wireless communication, and RFID reader to identify personal. The back-end has a serial forwarder to propagate measurment results, monitor program, and medical information server The implemented sensor node constructs a sensor network using the Zigbee protocol and is ported the tinyOS. The data gathering base node is linux-based terminal that can transfer a sensed medial data through wireless LAN. And, the medical information server stores the processed medical data and can promptly notify the urgent status to the connected medical team. Through our experiments, we've confirmed the possibility of ubiquitous healthcare system based on sensor network using the Zigbee.

Design and Implementation of a ubiquitous health care system (유비쿼터스 헬스 케어 시스템의 설계 및 구현)

  • Kim, Jeong-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.921-924
    • /
    • 2007
  • In this paper, we have implemented a ubiquitous healthcare system that can measure and check human's health in anytime and anywhere. The implemented prototype are composed of both front-end and back-end. The front-end have several groups: environment sensor group such as temperature, humidity, photo, voice sensor, health sensor group such as blood pressure, heart beat, electrocardiogram, spo2 sensor, gateway for wired/wireless communication, and RFlD reader to identify personal. The back-end has a serial forwarder to propagate measurment results, monitor program, and medical information server. The implemented sensor node constructs a sensor network using the Zigbee protocol and is ported the TinyOS. The data gathering base node is linux-based terminal that can transfer a sensed medial data through wireless LAN. And, the medical information server stores the processed medical data and can promptly notify the urgent status to the connected medical team. Through our experiments, we've confirmed the possibility of ubiquitous healthcare system based on sensor network using the Zigbee.

  • PDF

Respiratory air flow measuring technique without sensing element on the flow stream (호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술)

  • Lee, In-Kwang;Park, Jun-Oh;Lee, Su-Ok;Shin, Eun-Young;Kim, Kyung-Chun;Kim, Kyung-Ah;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards (ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석)

  • Kim, Sang-Kon;Yoo, Done-Sik;Kim, Tae-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.307-312
    • /
    • 2012
  • In this paper, we perform a complexity analysis for implementation of the ISO/IEEE 11073 Personal Health Device (PHD) standards in order to check the required system resources when ISO/IEEE 11073 PHD standards are implemented on the embedded system. Base on the implemented programs complying the PHD standards for a weighing scale, a blood pressure monitor, and a glucose meter among the various personal health devices, we make a pseudo-code. And then from the two different points of view such as program memory space and data memory space, we make a complexity analysis model. Because system resources or capability are strongly restricted in the personal health devices, our research work is very useful to estimate the required system resources.

Bio-Signal Detection Monitoring System Using ZigBee and Wireless Network (ZigBee와 무선 네트워크를 이용한 생체신호 검출 모니터링 시스템)

  • Kim, Kuk-Se;Bang, Sun-Kwang;Lee, Jeong-Gi;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.477-481
    • /
    • 2007
  • The emergency patient who occurs from the place where it is various the control which is quick must come to accomplish in Ubiquitous environment. In the body of the patient or the old person the organism signal sensor about under attaching condition of the patient at real-time about under the monitor ring about under disposing the control which is quick against the emergency patient does to become accomplished at the case real-time when the above will get in the body of the patient or the old person. Using ZigBee (802.15.4) system base on Shor wireless communication protocol because of complement wireless of hospital. This system use ZigBee (802.15.4) system to get for electrocardiogram, blood pressure and pulse bio-sensors. This paper constructs Bio-Sensor communication monitoring system and transmission rate and the delay which it follows possibility and node occurrence rate of wireless sensor network construction hour transmission session it leads and it verifies the effectiveness.

  • PDF

Bone Mineral Density and Affecting Factors in College Women

  • Na, Hye-Bok;Jung, Shin-Yong
    • Journal of Community Nutrition
    • /
    • v.1 no.2
    • /
    • pp.98-107
    • /
    • 1999
  • The purpose of this study was to investigate Bone Mineral Density(BMD) and affecting factors on BMD of college women in Seoul. The subjects were 47 healthy college women aged 18-25 years. Antrophometric and body fat measurements were performed by Bioelectrical Impedance Fatness Analyzer(Tanita TVF 202). Blood pressure and pulse frequency were measured. Dietary intakes and general living habits were examined through questionnaires and nutrient intakes were analyzed by Computer Aided Nutritional Analysis(CAN) program for professional. Serum total cholesterol, TG(triglyceride), HDL-cholesterol, total protein, albumin, GOT, calcium were measured by Spotchem(SP-4410). Serum osteocalcin and alkaline phosphatase(ALP) were measured to monitor bone formation. BMD of lumbar spine(L2-L4), right hip(neck, ward's triangle, trochanter) and right forearm were measured by Dual Energy X-ray Absorptiometry(DEXA). Muscle strength was measured by examining leg flexion strength(right and left), leg extension power(right and left), handgrip power(right and left) and back strength. All data were statistically analyzed by the SAS PC package program. BMD of college women was normal(by WHO, 1994). Their muscle strength was bad(by national fitness guidebook, 1995). Only a mall number of them exercised (32.6% of subjects). There was no significant difference among BMD, muscle strength and % body fat(p<0.05). There were significant differences between BMD and total cholesterol as well as TG and VLDL-cholesterol(p<0.05). Total cholesterol was associated with decreasing BMD of the right forearm(p<0.05). TG and VLDL-cholesterol are associated with increasing BMD of right hip ward's triangle(p<0.05). There were significant differences among BMD, ALP and serum total protein. ALP was associated with decreasing BMD of the right forearm(p<0.05). There were significant differences between BMD and Ca as well as between Na and K intakes (p<0.05). Intakes of Na and K were associated with decreasing BMD of the right forearm (UD)(p<0.05). There were significant differences between in BMD and pulse frequently and serum albumin (p<0.05). Serum albumin is associated with increasing BMD of L3-L4(p<0.05), right hip neck(p<0.05). %Body fat, TG, VLDL-C, Ca intake, pulse frequency and serum albumin were associated with increasing BMD(p<0.05). Intakes of Na and K, ALP, total cholesterol, total cholesterol, total protein and height are associated with decreasing BMD(p<0.05). Overall results indicate that Ca intake but to be moderate in protein and Na intakes in order to increase BMD. Body exercise was recommended to increase BMD as well.

  • PDF

THE USE OF BISPECTRAL ANALYSIS AND HEMODYNAMIC MONITORING IN PATIENTS UNDERGOING INTRAVENOUS SEDATION FOR MINOR ORAL SURGERY (구강악안면외과 소수술시 정맥 의식하 진정법에서의 Bispectral Index and Hemodynamics monitoring을 이용한 진정 깊이에 관한 연구)

  • Shin, Jung-Sub;Min, Hyun-Gi;Lee, Ju-Hyon;Lee, Dong-Hyun;Kim, Myung-Rae;Kang, Na-Ra
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.567-571
    • /
    • 2008
  • Purpose: The purpose was to assess the usefulness of midazolam in patients undergoing minor oral surgery under conscious sedation. Materials and methods: Bispectral index was examined in 20 patients receiving oral minor surgery with conscious sedation supplemented with local anesthesia. All patients included were ASA I and had no contraindications to the study medications. The patients were escorted to the day surgery operation room where, before the commencement of the sedation and surgical procedures, routine monitoring was applied, including the noninvasive monitoring of arterial blood pressure, arterial oxygen saturation, and 3-lead electrocardiogram (Electrocardiogram). Bispectral index electrodes were applied on the frontotemporal region after cleansing the skin with alcohol. Bispectral index was calculated with the Electrocardiogram monitor (A-2000; Aspect Co.). Midazolam was then titrated (initially 3mg wait 2min and 2mg). Vital sign and Bispectral index checked every 5 minute until the end of the procedure. The results were then compared. Results: The Bispectral index index values throughout the sedation study period alter many level. The index was dropped at 5 minutes after administration, but raised at injection and odontomy procedure. During the operation, mean Bispectral index index was higher than conscious sedation index range($60{\sim}80$). The amnesic effect was shown 17 cases out of 20 cases(85%). Conclusion: Conscious sedation technique using midazolma is a safe and effective method of controlling behavior in oral and maxillofacial surgery.