• Title/Summary/Keyword: Blood glucose self-monitoring

Search Result 28, Processing Time 0.021 seconds

A Study on the Performance and Utilization of Results of Self-monitoring of Blood Glucose in Type Ⅱ Diabetes (일 병원 제2형 당뇨병환자의 자가혈당검사 수행 및 활용 실태)

  • Ha, Jung-Mi;Kim, Dong-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.16 no.2
    • /
    • pp.330-338
    • /
    • 2010
  • Purpose: This study was conducted to investigate performance of self-monitoring of blood glucose and the utilization of results for people with type II diabetes. Method: Data was collected from 177 patients with type II diabetes using a questionnaire from August to September, 2009. Result: Most participants performed self-monitoring of blood glucose in the correct way while some misused the lancet or test strips. In the utilization of results for self-monitoring blood glucose data, 62% of participants always recorded the data, 46% always understood the cause for hyperglycemia or hypoglycemia, 25% changed their diet, 23% regulated their exercise-amount, and 11% of participants adjusted the drug dosage. There were significant differences in the performance of self-monitoring of blood glucose and the utilization of results according to the characteristics in the self-monitoring subjects such as awareness of HbA1c, target fasting glucose level, target fasting glucose level 2 hours after meal etc. Conclusion: Systemic self-monitoring of blood glucose education which includes the utilization of self-monitoring of blood glucose needs to be developed for type II diabetic patients.

Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

  • Hwang, Joon Ho;Sohn, Yong-Hak;Chang, Seong-Sil;Kim, Seung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.301-308
    • /
    • 2015
  • Purpose: We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods: Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ${\leq}2,300g$ or were ${\leq}36$ weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). Results: The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels ${\leq}60mg/dL$, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment, after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ${\leq}60mg/dL$), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Conclusion: Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

Screening for diabetes mellitus using gingival crevicular blood with the help of a self-monitoring device

  • Gaikwad, Subodh;Jadhav, Varsha;Gurav, Abhijit;Shete, Abhijeet R.;Dearda, Hitesh M.
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.1
    • /
    • pp.37-40
    • /
    • 2013
  • Purpose: The purpose of study was to compare blood glucose in capillary finger-prick blood and gingival crevice blood using a self-monitoring blood glucose device among patients with gingivitis or periodontitis. Methods: Thirty patients with gingivitis or periodontitis and bleeding on probing (BOP) were chosen. The following clinical periodontal parameters were noted: probing depth, BOP, gingival bleeding index, and periodontal disease index. Blood samples were collected from gingival crevicular blood (GCB) and capillary finger-prick blood (CFB). These samples were analyzed using a glucose self-monitoring device. Results: Descriptive statistical analysis has been carried out in the present study. Data were analyzed using a Pearson's correlation coefficient and Student's t-test. A r-value of 0.97 shows very strong correlation between CFB and GCB, which was statistically highly significant (P<0.0001). Conclusions: The authors conclude that GCB may serve as potential source of screening blood glucose during routine periodontal examination in populations with an unknown history of diabetes mellitus.

Effects on Glycemic Control by Continuous Self Monitoring of Blood Glucose in Diabetic Patients (당뇨병환자의 지속적 자가 혈당관리에 따른 혈당조절의 효과)

  • Jang, Gyeong-Wha;Kwon, Myung-Soon
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.17 no.2
    • /
    • pp.104-111
    • /
    • 2010
  • Purpose: To evaluate the effects of continuous self monitoring of blood glucose (SMBG) on glycemic control in diabetic patients. Methods: Among the diabetic patients who visited the department of internal medicine in H hospital from April 1 to October 27 2008, 76 patients were divided into the experimental group (n=39) and control group (n=36). The experimental group was required to measure blood glucose levels at least twice every other day using SMBG; their compliance was aided by weekly telephone reminders for 3 months after discharge. Glycated hemoglobin, fasting blood sugar and postprandial 2 hours glucose level, triglyceride and high density lipoprotein were measured before and after the study. Results: Baseline characteristics were not different between the experimental and control groups. Three months later, there was a significant difference in postprandial glucose between the two groups (t=-2.042, p=.045). Conclusion: There was significant improvement of glycemic control after the use of continuous SMBG, suggesting its value in strict glycemic control and the merit of an aggressive education program.

  • PDF

Effect of Self-Monitoring of Blood Glucose Based Diabetes Self-Management Education on Glycemic Control in Type 2 Diabetes (자가혈당 측정결과기반 당뇨교육프로그램이 제2형 당뇨병환자의 혈당조절에 미치는 효과)

  • Sim, Kang Hee;Hwang, Moon Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.19 no.2
    • /
    • pp.127-136
    • /
    • 2013
  • Purpose: The aim of the study was to evaluate the effect of self-monitoring of blood glucose (SMBG)-based Diabetes Self-Management Education (DSME) on glycemic control in type 2 diabetes. Methods: This study was designed to compare changes in glycemic control over 12months in SMBG-based DSME group (n=65) versus control group (n=65). Data were obtained from medical records type 2 diabetic patients treated with oral antidiabetic agents and above HbA1c 7.0% from June 2006 to August 2008. All participants completed DSME defined as informational intervention of lifestyle habits and reinforcement of educational Monthly News letter delivered by the diabetes nurse educator. SMBG-based DSME group requested to measure blood glucose 7 times a day for a week and to record their diary and received counseling with a focus on diet and lifestyle during the education. Assessments were conducted baseline, 3, 6 and 12 months. HbA1c was used as an index of glycemic control. Results: 12 months later, the level of HbA1c was reduced by $1.28{\pm}1.68%$ in experimental group and $0.49{\pm}1.05%$ in the control group. We found a significant effect of $Time^*$ Group interaction (p=.013). Conclusion: SMBG-based DSME for patients with type 2 diabetes with oral antidiabetic agents was effective in improving glycemic control and maintaining long-term glycemic control.

Diabetes Management and Hypoglycemia in Safety Sensitive Jobs

  • Lee, See-Muah;Koh, David;Chui, Winnie Kl;Sum, Chee-Fang
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • The majority of people diagnosed with diabetes mellitus are in the working age group in developing countries. The interrelationship of diabetes and work, that is, diabetes affecting work and work affecting diabetes, becomes an important issue for these people. Therapeutic options for the diabetic worker have been developed, and currently include various insulins, insulin sensitizers and secretagogues, incretin mimetics and enhancers, and alpha glucosidase inhibitors. Hypoglycemia and hypoglycaemic unawareness are important and unwanted treatment side effects. The risk they pose with respect to cognitive impairment can have safety implications. The understanding of the therapeutic options in the management of diabetic workers, blood glucose awareness training, and self-monitoring blood glucose will help to mitigate this risk. Employment decisions must also take into account the extent to which the jobs performed by the worker are safety sensitive. A risk assessment matrix, based on the extent to which a job is considered safety sensitive and based on the severity of the hypoglycaemia, may assist in determining one's fitness to work. Support at the workplace, such as a provision of healthy food options and arrangements for affected workers will be helpful for such workers. Arrangements include permission to carry and consume emergency sugar, flexible meal times, selfmonitoring blood glucose when required, storage/disposal facilities for medicine such as insulin and needles, time off for medical appointments, and structured self-help programs.

Comparison of Blood Glucose Levels from the Fingertips of Both Patients with and without Diabetes Who are Receiving Dextrose Fluid Therapy (포도당 수액요법을 받는 당뇨병 환자와 비당뇨병 환자의 양쪽 손가락 끝 혈당치 비교)

  • Park, Suk Hyun;Lee, Chang Kwan;Kim, Yeon Woo;Kwon, Chi Hye
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.2
    • /
    • pp.127-135
    • /
    • 2016
  • Purpose: The aim of this study was to identify the effect of dextrose intravenous fluid (IVF) on the blood glucose levels taken from both fingertips of patients with diabetes mellitus (DM) and those without DM. Methods: From October 2012 to February 2013, 21 DM and 25 non-DM patients were recruited. Blood glucose levels taken from the both fingertips of patients at 7AM while IVF was not infusing and at 11AM, 5PM, and 9PM while IVF was infusing. Results: The differences between the mean values of blood glucose from the fingertips at four different times was not statistically significant in DM patients as well as non-DM patients. Also intra-class correlation for blood glucose levels from the fingertips with and without IVF infusion in both groups was shown over about 0.95 at each time (p<.001). Conclusion: Blood glucose levels measured in the same fingertips of both arms were the same regardless of dextrose IVF infusion. The results indicated that IVF with dextrose may not have any significant effect on the fingertip results of blood glucose level. This study may suggest that patients' both arms and any fingertips can be used for blood glucose monitoring even when the patients are on dextrose IVF infusion.

Clinical Benefits of Self-monitoring of Blood Glucose in Non-insulin Treated Patients with Type 2 Diabetes : A systematic Review and Meta-analysis (제 2형 당뇨 환자에서 자가혈당측정의 임상적 유용성 : 체계적문헌고찰 및 메타분석)

  • Choi, Yoon-Young;Sohn, Hyun-Soon;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.183-192
    • /
    • 2010
  • While Self-monitoring of blood glucose (SMBG) has been recommended in some diabetes mellitus (DM) patients population according to the 2010 American Diabetes Association (ADA), 2007 Korean Diabetes Association (KDA), 2005 International Diabetes Federation guideline, it is excluded from a routine insurance coverage for outpatients in Korea. The objective of this study is to meta-analyze the impact of SMBG on HbA1c in non insulin-treated diabetes mellitus (NIT) DM patients. Published clinical literatures were identified through electronic database searches from inception and until May 2010. Studies were selected if they met the following inclusion criteria: 1) randomized controlled trials (RCTs), 2) comparing SMBG with non-SMBG in NIT type 2 diabetes, 3) measuring HbA1c as an outcome. Literature qualities were assessed by the Scottish Intercollegiate Guidelines Network Checklist. The mean difference of HbA1c between the 2 groups was pooled from non-heterogeneous 6 RCTs by meta-analysis using Review Manger (RevMan) Version 5.0 program. Pooled results demonstrated that SMBG is associated with a statistically significant improvement in glycemic control (mean HbA1c difference -0.23, 95%CI -0.32, -0.13). Sensitivity analysis showed that glycemic controls were significantly improved in patients with shorter study duration, more frequent self-monitoring, higher baseline HbA1c value, and without prior SMBG experiences. Conclusively SMBG is effective in improving glycemic control in NIT DM patients, but additional evidences from further researches in Korean patients and cost-effectiveness analysis would be necessary to make a suggestion for coverage expansion.

Development of an Portable Urine Glucose Monitoring System (휴대용 뇨당 측정 시스템의 개발)

  • 박호동;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.397-403
    • /
    • 2002
  • Urine glucose monitoring system is a self-monitoring system that display the glucose level by non-invasive measurement method. In this paper, We developed a noninvasive urine glucose monitoring system that improved defects of urine glucose measurement with a colorimeter method and invasive blood glucose measurement method. This system consist of bio-chemical sensor for urine glucose measurements, signal detecting part, digital and signal analysis part, display part and power supplying part. The developed bio-chemical sensor for the measurement of urine glucose has good reproducibility, convenience of handing and can be mass-produced with cheap price. To evaluate the performance of the developed system, We performed the evaluation of confidence about the detection of glucose level by a comparison between a standard instrument in measuring glucose level and the developed system using standard glucose solutions mixed with urine. Standard error was 2.85282 from the evaluation of confidence based on regression analysis. Also, In analysis of S.D(standard deviation) and C.V(coefficient of validation) that are important parameters to evaluate system using bio-chemical sensor, S.D was 10% which falls under clinically valid value, 15%, and C.V was under 5%. Consequently from the above results, compared to blood glucose measurement, the system performance is satisfactory.