• 제목/요약/키워드: Blood flow velocity

검색결과 286건 처리시간 0.023초

뉴턴유체와 혈액의 맥동유동시 탄성혈관의 운동이 벽면전단응력분포에 미치는 영향 (Effects of Elastic Blood Vessel Motions on the Wall Shear Stresses for Pulsatile Flow of a Newtonian Fluid and Blood)

  • 노형운;김재수;박길문;서상호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.318-323
    • /
    • 2001
  • Characteristics of the pulsatile flow in a 3-dimensional elastic blood vessel are investigated to understand the blood flow phenomena in the human body arteries. In this study, a model for the elastic blood vessel is proposed. The finite volume prediction is used to analyse the pulsatile flow in the elastic blood vessel. Variations of the pressure, velocity and wall shear stress of the pulsatile flow in the elastic blood vessel are obtained. The magnitudes of the velocity waveforms in the elastic blood vessel model are larger than those in the rigid blood vessel model. The wall shear stresses on the elastic vessel vary with the blood vessel motions. Amplitude indices of the wall shear stress for blood in the elastic blood vessel are $4\sim5$ times larger than those of the Newtonian fluid. As the phase angle increased, point of the phase angle is are moved forward and the wall shear stresses are increased for blood and the Newtonian fluid.

  • PDF

상완동맥 Doppler 영상의 입사각 의존성과 Aliasing에 관한 연구 (The Study of Aliasing and Incidence Angle Dependence of Doppler Image on Humeral Artery)

  • 김상진;지태정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.379-387
    • /
    • 2008
  • 반접현상(Aliasing)을 제거하기위한 방법 중 속도범위(velocity scale)를 높이는 방법은 동일 조건하에서 속도범위를 높여줌으로써 혈류의 방향이 반대로 나타나는 현상이 점차 사라지는 것을 확인할 수 있었다. Doppler angle을 $0^{\circ}$에 가깝게 하는 실험에서는 각도의 변화에 따른 스펙트럼 파형에서 유의한 차이점을 발견을 하지 못했다. 실제 초음파 검사(Ultrasonography)를 시행할 때는 검사의 편의성과 신속성, 정확성을 고려해서 속도범위에 변화를 주어 검사함으로써 보다 정확한 검사가 시행되리라고 본다. 또한 Doppler Angle에 따라 혈류속도는 기하학적으로 증가하였으며, $70^{\circ}$ 이상에서는 측정불가능 할 정도로 수치가 급상승하여 혈류속도가 Doppler Angle에 크게 의존한다는 것을 알 수 있었다. 혈류의 방향에 따른 실험에서는 입사각이 $60^{\circ}$ 이상에서 오차범위가 증가하였고, $70^{\circ}$ 이상에서는 매우 큰 차이를 보였다. 따라서 입사각은 $60^{\circ}$ 이하가 적당하다고 보며, 사지 혈관(extremity vessel)의 혈류속도를 구하는 데 있어서 Doppler 각도는 $45^{\circ}$에서 $60^{\circ}$가 적절한 것으로 사료된다.

  • PDF

Effects of the Velocity Waveform of the Physiological Flow on the Hemodynamics in the Bifurcated Tube

  • Roh, Hyung-Woon;Kim, Jae-Soo;Suh, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.296-309
    • /
    • 2003
  • The periodicity of the physiological flow has been the major interest of analytic research in this field up to now Among the mechanical forces stimulating the biochemical reaction of endothelial cells on the wall, the wall shear stresses show the strongest effect to the biochemical product. The objective of present study is to find the effects of velocity waveform on the wall shear stresses and pressure distribution along the artery and to present some correlation of the velocity waveform with the clinical observations. In order to investigate the complex flow phenomena in the bifurcated tube, constitutive equations, which are suitable to describe the rheological properties of the non-Newtonian fluids, are determined, and pulsatile momemtum equations are solved by the finite volume prediction. The results show that pressure and wall shear stresses are related to the velocity waveform of the physiological flow and the blood viscosity. And the variational tendency of the wall shear stresses along the flow direction is very similar to the applied sinusoidal and physiological velocity waveforms, but the stress values are quite different depending on the local region. Under the sinusoidal velocity waveform, a Newtonian fluid and blood show big differences in velocity. pressure, and wall shear stress as a function of time, but the differences under the physiological velocity waveform are negligibly small.

Fluid-structure interactions of physiological flow in stenosed artery

  • Buriev, Bahtiyor;Kim, Tae-Dong;Seo, Tae-Won
    • Korea-Australia Rheology Journal
    • /
    • 제21권1호
    • /
    • pp.39-46
    • /
    • 2009
  • Atherosclerosis is a disease that narrows, thickens, hardens, and restructures a blood vessel due to substantial plaque deposit. The geometric models of the considered stenotic blood flow are three different types of constriction of cross-sectional area of blood vessel; 25%, 50%, and 75% of constriction. The computational model with the fluid-structure interaction is introduced to investigate the wall shear stresses, blood flow field and recirculation zone in the stenotic vessels. The velocity profile in a compliant stenotic artery with various constrictions is subjected to prescribed physiologic waveform. The computational simulations were performed, in which the physiological flow through a compliant axisymmetric stenotic blood vessel was solved using commercial software ADINA 8.4 developed by finite element method. We demonstrated comparisons of the wall shear stress with or without the fluid-structure interaction and their velocity profiles under the physiological flow condition in the compliant stenotic artery. The present results enhance our understanding of the hemodynamic characteristics in a compliant stenotic artery.

성상신경절 차단후 총경동맥, 액와동맥, 상완동맥, 요골동맥의 혈류속도변화 (Flow Velocity Changes of Carotid, Axillary, Brachial and Radial Artery after Stellate Ganglion Block)

  • 서영선
    • The Korean Journal of Pain
    • /
    • 제8권1호
    • /
    • pp.55-59
    • /
    • 1995
  • Stellate ganglion block (SGB) is applicated frequently to increase the blood flow and to reduce the pain in head, neck and upper extremity. The effects of SGB are able to be estimated by clinical signs and symptoms of Horner's syndrome, skin warmth, anhydrosis, etc. The effects are also estimated by sympathetic function and the blood flow. Blood flow velocities and pulsatility indices of common carotid,d axillary, brachial and radial artery were measured by Doppler flowmeter after SGB with 1% lidocaine at C6 level. Blood velocities of all arteries were increased and pulsatility indices of all arteries were decreased. This results suggest that SGB increase the blood flow of head and upper extremity and Doppler flowmeter is a good indicator of the effects of SGB.

  • PDF

혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구 (A study on the development of CW(Continuous-Wave) Doppler system for measuring bi-directional blood flow information.)

  • 강충신;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1239-1242
    • /
    • 1987
  • With the convention CW Doppler velocity meter, bi-directional velocities cannot be separated. The new CW Doppler system usee quadrature detection and phase rotation to Produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, can easily differentiate typical artery flow from vein flow. and measure both velocity characteristics qualitatively.

  • PDF

TCD를 이용한 말초성(末梢性) 구안괘사환자에 대(對)한 임상적(臨床的) 고찰(考察) (The Clinical Study on Bell's Palsy Patients with TCD Measurement)

  • 이병렬;안택원;이현
    • 대한약침학회지
    • /
    • 제6권2호
    • /
    • pp.91-104
    • /
    • 2003
  • Objective : This study was carried to make out the connection between cerebral artery blood flow velocity and ischemic theory that presumed the cause of Bell's palsy. Method : We measured cerebral artery blood flow velocity each external carotid artery, internal carotid artery, common carotid artery, siphon, superficial temporal artery by TCD to 20 patients who diagnosed as facial nerve palsy from march 2001 to July 2001 and all objectives devided two groups as palsy side. A group is right side facial nerve palsy and B group is left facial nerve palsy. Results : 1. There is no effective change of blood flow in external carotid artery either A, B group. 2. There is no effective change of blood flow in internal carotid artery either A, B group. 3. There is no effective change of blood flow in common carotid artery either A, B group. 4. There is no effective change of blood flow in siphon artery either A, B group. 5. There is no effective change of blood flow in superficial temporal artery either A, B group.

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

  • Sung, Kun-Hyuk;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • 제21권2호
    • /
    • pp.119-126
    • /
    • 2009
  • A numerical analysis is performed to investigate the effect of rotation on the blood flow characteristics with four different angular velocities. The artery has a cylindrical shape with 50% stenosis rate symmetrically distributed at the middle. Blood flow is considered a non-Newtonian fluid. Using the Carreau model, we apply the pulsatile velocity profile at the inlet boundary. The period of the heart beat is one second. In comparison with no-rotation case, the flow recirculation zone (FRZ) contracts and its duration is reduced in axially rotating artery. Also wall shear stress is larger after the FRZ disappears. Although the geometry of artery is axisymmetry, the spiral wave and asymmetric flow occur clearly at the small rotation rate. It is caused that the flow is influenced by the effects of the rotation and the stenosis at same time.

유정란 태아외부혈관의 단계적으로 분기되는 동맥 분지관 내부 혈액 유동특성의 in-vivo 계측 (In-vivo Measurements of Blood Flow Characteristics in the Arterial Bifurcation Cascade Networks of Chicken Embryo)

  • 이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2006
  • The arteries are very important in cardiovascular system and easily adapt to varying flow and pressure conditions by enlarging or shrinking to meet the given hemodynamic demands. The blood flow in arteries is dominated by unsteady flow phenomena due to heart beating. In certain circumstances, however, unusual hemodynamic conditions cause an abnormal biological response and often induce circulatory diseases such as atherosclerosis, thrombosis and inflammation. Therefore quantitative analysis of the unsteady pulsatile flow characteristics in the arterial blood vessels plays important roles in diagnosing these circulatory diseases. In order to verify the hemodynamic characteristics, in-vivo measurements of blood flow inside the extraembryonic arterial bifurcation cascade of chicken embryo were carried out using a micro-PIV technique. To analyze the unsteady pulsatile flow temporally, the (low images of RBCs were obtained using a high-speed CMOS camera at 250fps with a spatial resolution of $30{\mu}m\times30{\mu}m$ in the whole blood vessels. In this study, the unusual flow conditions such as flow separation or secondary flow were not observed in the arterial bifurcations. However, the vorticity has large values in the inner side of curvature of vessels. In addition, the mean velocity in the arterial blood vessel was decreased and pulsating frequency obtained by FFT analysis of velocity data extracted in front of the each bifurcation was also decreased as the bifurcation cascaded.

  • PDF

신경초음파 검사에서 Doppler소견의 판독 (Interpertation of Doppler Indicies in Neurosonologic Examinations)

  • 김제
    • Annals of Clinical Neurophysiology
    • /
    • 제1권1호
    • /
    • pp.47-54
    • /
    • 1999
  • The Doppler in neurosonologic examination could be applied to blood flow to determine its movement, the direction of its movement, and how fast it is. Indicies of the Doppler study denoted velocity, direction, and amount of RBC in the examined vessel. Systolic. diastolic, and mean blood flow velocities represent velocity of RBCs in a sample volume. Blood flow direction to the probe means direction of RBC to the probe. Size of amplitude displays toe amount of the RBCs passing the sample volume. Spectral broadening means presence of turbelence. The RBC movements and hemodynamics at the examined vessels can be estimated by analysis of Doppler indicies The formation and meaning of each of neurosonologic Doppler study is described in the present review.

  • PDF