• Title/Summary/Keyword: Blood Vessel Prosthesis

Search Result 12, Processing Time 0.029 seconds

Crossed Renal Ectopia and Aorto-Occlusive Disease: A Management Strategy

  • Ng, Eugene;Campbell, Ian;Choong, Andrew MTL;Dunglison, Nigel;Aziz, Maged
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.371-374
    • /
    • 2015
  • We present a rare case of a patient with aortoiliac occlusive disease on the background of type A crossed renal ectopia, for whom open surgical intervention was required. Aortic exposure in patients with concomitant crossed renal ectopia can present technical challenges to the vascular surgeon. The knowledge of variations in the ectopic renal blood supply is of paramount importance when performing surgery to treat this condition and affects the choice of surgical exposure. We present and discuss the operative details of our patient and outline an approach to this subset of patients.

Experimental Study of Adjustable Pulmonary Artery Banding Device (가변성 폐동맥 협착기구의 실험적 연구)

  • 홍유선;박영환
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.747-751
    • /
    • 1997
  • We developed a subcutaneously adjustable new pulmonary artery banding device which can be easily tightened or released in patients with unstable postoperative hemodynamics. The banding device consists of stainless spring which is enveloped with PTFE, nd polyvinyl catheter(5F). And the adjuster consists of another polyvinyl tube with forming cap. We mark transluscent polyvinyl tube 1mm each in length. 6 dogs weighing 15 to 25 kg underwent banding of descending thoracic aorta with the device. At postoperative 1 and 2 day, the device was effectively banded and released. Even 3 months later, we noted effective banding with some degree of vessel injury. The preliminary animal study suggests that this new device may be applicable in patient with excessive pulmonary blood flow.

  • PDF

Algorithmic approach to the lymphatic leak after vascular reconstruction: a systematic review

  • Nicksic, Peter John;Condit, Kevin Michael;Nayar, Harry Siva;Michelotti, Brett Foster
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.404-409
    • /
    • 2021
  • Background To date, there are no consensus guidelines for management of lymphatic leak in groin vascular reconstruction patients. The goal of this study is to review the relevant literature to determine alternatives for treatment and to design an evidence-based algorithm to minimize cost and morbidity and maximize efficacy. Methods A systematic review of the literature was conducted per Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol. Two independent reviewers applied agreed-upon inclusion and exclusion criteria to eligible records. Studies that included patients who underwent groin dissection for oncologic diagnoses and level 5 data were excluded. Interventions were then categorized by efficacy using predetermined criteria. Results Our search yielded 333 records, of which eight studies were included. In four studies, the success of lymphatic ligation ranged from 75% to 100%, with average days to resolution ranging from 0 to 9. Conservative management in the form of elevation, compression, and bedrest may prolong time to resolution of lymphatic leak (14-24 days) and therefore cost. Conclusions The majority of patients should be offered early operative intervention in the form of lymphatic ligation with or without a primary muscle flap. If the patient is not an operative candidate, a trial of conservative management should be attempted before other nonsurgical interventions.

A Case of Metastatic breast Cancer and Reconstruction of Superior Vena Cava by Woven Dacron Y Graft (전이성 유암에서 Woven Dacrorl Y graft를 이용한 상대공정맥 재건술 -치험 III-)

  • 이원진;신호승
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.346-349
    • /
    • 1996
  • This 32 year old female patient underwent left radical mastectomy due to ductal carcinoma on May 1990, and treated with FAM (5-fluorouracil, Adriamycin and Mitomycin C) regimen postoperatively. However, right cervical Iymph node enlargement and facial edema progressively developed since December 199). On April 1994, operation was performed, and findings were as followes; x4$\times$5$\times$7 to 1 : 1 $\times$ 1 cm sized multiple enlarged and hyperemic Iymph nodes were scatterred throughout submandibular area to the junction of superior vents cave and pericardium, and partially invaded both anterior segmental lobe, sternum and both distal tip of clavicles. After radical dissection of the nodes of neck and mediastinal nodes, and wedge resection of both anterior segments of lung, and partial resection of both clavicle tips and total sternum. The both innominate veins and superior vena cava were partially obstructed by invaded cancer SVC reconstruction was done with preclotted 10$\times$ 10$\times$ 18mm Y shap d woven Dacron graft, which was anastomosed to the point of the junction of subclavian vein and jugular vein after cross clamping both veins and 2cm above the pericardial junction with one arm clamp. After maintaining blood drainage to the SVC from the right side, left innominate vein was anastomosed with 4-0 Prolene continuous running suture. Bone cement was used for resected sternal portion and clavicular ends were fixed to postal portion with 18 Gauge wires. The patient was treated with radiation and chemotherapy after discharge, and there were no evidence of regrowing of the mass nor obstruction of the graft inspite of no antithrombotic therapy.

  • PDF

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Histologic Change of Extracorporeal Irradiated Autogenous Joint Transplantation in Rabbit's Knee (가토에서 체외 방사선 조사후 재이식한 자가관절의 조직학적 변화)

  • Kim, Jae-Do;Cho, Myung-Rae;Yoo, Kyung-Sik;Kim, Young-Chang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 1999
  • A new method of limb sparing by resection, extracorporeal irradiation and reimplantation has several theoretical advantages. This method preserves the mobility of a joint and avoids the problem of loosening or breakage of tumor prosthesis. This study involved using extracorporeal irradiated autogenous joint transplantation for reconstruction after en bloc resection, and observed the periods of functional union and histological changes in irradiated tissue of the knee joint. This study also aimed to clarify whether the degeneration of articular cartilage is induced in rabbits by a single 50Gy dose of irradiation at the knee joint. Twenty New Zealand rabbits about three kilograms were randomized into two groups of 10 rabbits each. In group 1, as control, we resected the knee joint followed by reimplantation without irradiation. Group 2 received extracorporeal irradiation on the resected knee joint followed by reimplantation. Following are the results of these observations. The osteotomy site showed external callus formation in the roentgenographic finding eight weeks after reimplantation. There was marked degenerative changes in the collagen fiber of the irradiated anterior cruciate ligament and meniscus during the fourth week, but new blood-vessel formation was observed in the vicinity. There was degenerative changes in the collagen fiber of articular cartilage treated extracorporeal irradiation at four and eight weeks in the scanning electron micrographic findings. These findings was in contrast to those of subchondral bone which showed decreased cellularity and empty lacuna at four and eight weeks. Autoradiography demonstrated active [$^3H$]uridine incorporation by irradiated chondrocyte at eight weeks after reimplantation. These results indicate that when destruction of the articular cartilage and soft tissue of the knee joint is not severe, extracorporeal irradiation and reimplantation can be used with several advantage in maintaining movement of the joint while avoiding problems of tumor prosthesis and rejection, and therefore extracorporeal irradiated autogenous joint transplantation can be used as a limb-sparing procedure for temporary biological spacer in the childhood bone tumor around the knee.

  • PDF

Intracardiac Migration of a Renal Stent from the Left Renal Vein to the Right Ventricle during the Treatment of Nutcracker Syndrome - A case report - (Nutcracker Syndrome를 위해 왼콩팥정맥에 삽입한 스텐트의 우심실 이동 - 1예 보고 -)

  • Kim, JaeBum;Choi, Sae-Young;Park, Nam-Hee;Kum, Dong-Yoon;Park, Hoon;Hwang, Eun Ah
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.100-103
    • /
    • 2010
  • We report her on a rare case of a renal stent that migrated into the right ventricle in a patient with nutcracker syndrome. A 29-year-old woman was admitted to the hospital and she was suffering from flank pain. The computed tomography of the abdomen demonstrated that the left renal vein was compressed between the abdominal aorta and the superior mesenteric artery (nutcracker syndrome). A self expandable stent was placed across the left renal vein for treating her nutcracker syndrome. The next day after the procedure, the follow up chest radiograph showed that the displaced stent had migrated into the right ventricle. After percutanous endovascular stent removal had failed, the stent was ultimately removed by performing cardiac surgery. At the $6^{th}$ postoperative month, there have been no abdominal or cardiac symptoms.

Histological Analysis of Autologous Pericardial Tissue Used as a Small-Diameter Arterial Graft (소구경 동맥이식편으로 사용한 자가심란의 조직학적 분식)

  • Yang Ji-Hyuk;Sung Sang-Hyun;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.261-268
    • /
    • 2006
  • Background: Current vascular prostheses are still inadequate for reconstruction of small-diameter vessels. Autologous pericardium can be a good alternative for this purpose as it already possesses good blood compatibility and shows a mechanical behavior similar to that of natural arteries. However, the clinical use of autologous pericardial tissue as a small-diameter vascular graft has limitations due to mixed outcomes from uncertain biological behavior and difficulty to gain reliable patency results in animal experiments. To study this issue, we implanted fresh and glutaraldehyde-treated autologous pericardium as small-diameter arterial grafts in dogs, and compared their time-related changes histologically. Material and Method: As a form of 5mm-diameter arterial graft, one pair of autologous pericardial tissue was used for comparison between the glutaraldehyde-treated and the glutaraldehyde-untreated grafts in the bilateral carotid arteries in the same dog. The patency of the grafts were evaluated at regular intervals with Doppler ultrasonography. After the predetermined periods of 3 days, 2 weeks, 1 month, 3 months and 6 months, the grafts in each animal were explanted. The retrieved grafts were processed for light and electron microscopic analyses following gross observation. Result: Of 7 animals, 2 were excluded from the study because one died postoperatively due to bleeding and the other was documented as one side of the grafts being obstructed. All 10 grafts in the remaining 5 dogs were patent. Grossly, a variable degree of thromboses were observed in the luminal surfaces of the grafts at 3 days and 2 weeks, despite good patency. Pseudointimal smooth blood-contacting surfaces were developed in the grafts at f month and later. By light microscopy, mesothelial cell layers of the pericardial tissue were absent in all explanted grafts. Newly formed endothelial cell layers on the blood-contacting surface were observed in both the glutaraldehyde-treated and fresh grafts at 3 months and later. The collagen fibers became degraded by fragmentation in the fresh graft at 1 month and In the glutaraldehyde-treated graft at 3 months. At 6 months, the collagen layers were no longer visible in either the glutaraldehyde-treated or fresh grafts. By electron microscopy, a greater amount of coarse fibrin fibers were observed in the fresh grafts than in the glutaraldehyde-treated grafts and, more compact and well-arrayed layers were observed in the glutaraldehyde-treated grafts than in the fresh grafts. Conclusion: The glutaraldehyde-treated small-diameter pericardial arterial grafts showed a better endothelialization of the blood-contacting surface and a slower fragmentation of the collagen layers than the fresh grafts, although it has yet to be proven whether these differences are so significant as to affect the patency results between the groups.

The Clinical Analysis of Modified B-T Shunt Using 3 mm and 3.5 mm PTFE graft (3mm와 3.5mm PTFF graft를 이용한 변형 B-T 단락술의 임상적 분석)

  • 정성호;윤태진;임한중;민경석;서동만;윤소영;김영휘;고재곤;박인숙
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.716-722
    • /
    • 2000
  • Background: Modified Blalock-Taussig shunt using 3mm or 3.5mm PTFE graft has been performed in patients with small body weight or in candidates for single ventricle palliation. However, there are few reports concerning clinical outcomes in terms of pulmonary artery growth and shunt patency rate after shunt operations using such a small graft. Material and Method: Twenty-five patients rate after shunt operations using 3 or 3.5 mm sized grafts from September 1996 to August 1999. We retrospectively assessed the pulmonary artery growth and the shunt patency rate by reviewing the pre-and post-operative pulmonary angiograms. The risk factors for late death and second shunt operations were also analyzed. To assess the presence of any correlation between body weight and selection of the graft size, regression analysis was done in 81 cases of shunt operations performed during the same period. Result: There were 1(4%) early death and 5(20%) late deaths. The survivors were followed up for an average of 7.34 months. The pulmonary artery index increased significantly from 129$\pm$66$\textrm{mm}^2$/$m^2$ to 213$\pm$114 $\textrm{mm}^2$/$m^2$(p=0.002). The shunt patency rate assessed at postoperative 2, 4, 6 and 8 months were 82.5%, 77%, 73% and 42% respectively with a marked decline between 6 and 8 months. Asplenia was a frequent finding for the patients with late death although the incidence failed to reach statistical significance(p=0.078). Pre-operative diagnosis of PA with VSD was found to be a statistically significant risk factor for a second shunt operation(p=0.01). Body weight(a) at operation and graft size(b) used in the shunt operations revealed strong correlation and could be expressed by the following formula; b=0.128a + 3.233. Conclusion: Adequate growth of pulmonary artery and satisfactory early patency rate could be obtained by modified Blalock-Taussing shunt using 3mm or 3.5mm graft. However, during 6 to 8 months after shunt operations, the patency rate fell sharply, which implicates that close observation and early intervention are mandatory in this period.

  • PDF