• 제목/요약/키워드: Blood Parameter

검색결과 308건 처리시간 0.024초

혈관계 시스템 모델과 CFD의 결합을 통한 관상동맥 내 혈류의 수치적 해석 (Numerical analysis of the blood flow in coronary artery combining CFD method with the vascular system modeling)

  • 심은보;박명수;고형종;김경훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.152-157
    • /
    • 1999
  • For the simulation of the blood flow in coronary artery, the system modeling of coronary hemodynamics is combined with CFD technique. The blood flow in coronary artery interacts with the global coronary circulation. Especially in case of the coronary artery with stenosis, the interaction plays an important role in the hemodynamics of the circulation. In this study we present a combined numerical approach using both the CFD technique for flow simulation and the global system model of coronary circulation. We use a lumped parameter model for the global simulation of coronary circulation whereas the finite element method is employed to compute the viscous flow field in stenosed coronary artery, The time variation of the pressure drop due to stenosis is obtained from the proposed numerical method. Numerical results shows that the flow resistance and pressure drop due to stenosis has a relatively large value in systole.

  • PDF

환자의 박동형 심장의 폐순환 혈류 모델링에 대한 연구 (Hemodynamic Modeling of the Pulsatile Cardiac Pulmonary Perfusion for the Patient's Heart)

  • 김종세;김문수;최성욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1679-1682
    • /
    • 2008
  • Pulsatile Extracorporeal Membrane Oxygenation(ECMO) can mitigate the heart load and raise the patient's blood perfusion. But If the ECMO pulsate the blood flow during the systolic period, It can burden to the patient's heart. To avoid the heart injury, we have to consider the relation between output of ECMO, hemodynamic states and heart movement. To raise the efficacy of the pulsatile ECMO, we investigated the coronary perfusion, cardiac muscle tension and hemodynamic states during the ECMO perfusion by using the mathematical model of human blood circulatory system and ECMO. The outflow data of the pulsatile ECMO(T-PLS, Bioheartkorea, Korea) was obtained in vitro experiments. According to the phase and pumping rate of the ECMO, the heart's load and coronary perfusion could be adjusted to the proper levels. The results of the human- ECMO lumped parameter model showed that the synchronizing operation of the pulsatile ECLS can be helpful at stabilizing the patient's hemodynamic states.

  • PDF

양전자방출단층촬영을 이용한 심근혈류 및 관상동맥 혈류예비능 평가 (Evaluation of Myocardial Blood Flow and Coronary Flow Reserve Using Positron Emission Tomography)

  • 이병일;범희승
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.118-123
    • /
    • 2005
  • Positron emission tomography (PET) serves as a gold standard for noninvasive in vivo measurement of myocardial blood flow (MBF) and coronary flow reserve (CFR). CFR can be defined as the ratio of maximally vasodilated MBF over its basal flow. It is an important parameter for the evaluation of functional severity of coronary stenosis and prognositification in various diseases such as dilated cardiomyopathy. $^{13}NH_3,\;H_2^{15}O,\;^{82}Rb$ are widely used radiopharmaceuticals for measuring MBF and CFR, This review introduces imaging techniques and its clinical utility. Cardiac application or PET and PET/CT is expected to be increased in near future.

시메티딘 정맥투여가 사이크로스포린의 체내동태에 미치는 영향 (Effect of Cimetidine on the Pharmacokinetics of Intraveneous Cyclosporine in Human Subjects)

  • 최인;최준식
    • 한국임상약학회지
    • /
    • 제10권1호
    • /
    • pp.19-24
    • /
    • 2000
  • The effect of cimetidine on the pbarmacokinetic parameters of cyclosporine (intravenous administration) were determined in 6 healthy volunteers (22-48 years old, 48-62 kg) by cross-over design. Cyclosporine and cyclosporine metabolites in whole blood were analysed by fluororescence polarization immunoassay (TDx-FLX). The blood concentrations of cyclosporine After pretreatment with cimetidine (200 mg bid, for 3days) were increased significantly at 8-12 hrs compared to the control (p<0.05). The ratios of blood concentrations of cyclosporine metabolites (M1, M17) to parent drug were decreased significantly at 8-12 hrs (p<0.05). Total body clearance (CL) was also decreased significantly (p<0.05), and area under the curve $(AUC,\%)$ was increased but not significant.

  • PDF

Physiological Parameters in Cynomolgus Monkey

  • Kim, Choong-Yong;Han, Su-Cheol;Heo, Jeong-Doo;Yasuo Tarumoto;Lee, Hyun-Sook;Ha, Chang-Su;Kwon, Myung-Sang;Chung, Moon-Koo
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2003년도 추계학술대회
    • /
    • pp.148-148
    • /
    • 2003
  • The cynomolgus monkey(Macaca fascicularis) is used widely in efficacy and safety assessment of new drugs. The ranges of physiological variables are important end points in the toxicological study. Both the basic physiological variables such as body weight, body temperature, blood pressure, urine pH and blood variables such as biochemical and hematological variables were determined in nineteen male and sixteen female monkey prior to treatment.(omitted)

  • PDF

Rat의 intestine 각 부위에 수술적으로 투여 된 insulin 제제에 의한 혈당 변화 (Blood glucose change after surgical administration of insulin formula into rat intestinal regions)

  • 김남중;김명철
    • 대한수의학회지
    • /
    • 제42권2호
    • /
    • pp.283-288
    • /
    • 2002
  • The present study was carried out to examine the effect of insulin formula on blood glucose change in normal Sprague-Dawley male rats. Also, this study was performed to investigate the feasibility of oral insulin formula development. To administrate the insulin formula into intestine, the surgical technique, celiotomy, was performed in rats. Insulin formula was administrated at a dose of 24.5 IU/kg via duodenum, ileum, and colon of the rats, and the blood glucose level was measured. For the comparison, the vehicle without insulin was administrated into ileum via celiotomy. Also, this insulin formula was administrated into rats orally using sonde and the same parameter was treasured. The bloods of all groups were collected from tail veins using syringes at given time interval. Orally administrated group did not show the change of blood glucose level and control group slightly show the change of blood glucose level at 1 hour after celiotomy. All intestinally administrated groups showed the change of blood glucose level. Among the tested groups, ileac administration group and colonic administration group showed the significant change of blood glucose level. Particularly, ileac administration group showed the lowest blood glucose level. To calculate the bioavailability of intestinal and oral administration, insulin solution was injected subcutaneosly, common insulin injection route, into another normal rats. The bioavailability of ileac group was 8.3% when compared with subcutaneous injection, duodenal group was 1.8%, colonic group was 4.2%, and oral group was 0.2%, respectively.

스캔 인자에 따른 4D 위상 대조 자기공명영상을 이용한 스캔 시간 분석: 팬텀 연구 (Scan Time Analysis Using 4D Phase-Contrast MRI According to Scan Parameter: A Phantom Study)

  • 박지은;김정훈;황문정;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권5호
    • /
    • pp.179-184
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect according to the NEX, VENC, targeted cardiac phases on the velocity measurement of 4D phase-contrast MRI. Materials and Methods: The abdominal aortic phantom was made to experiment. The working fluid was mixed with water and glycerin to mimic the density and viscosity of human blood. The inlet velocity was Reynolds number 2000. The experimental conditions were NEX 1 and 4, VENC 102 cm/s and 200 cm/s, and 10 and 15 targeted cardiac phases, respectively. The average flow rate, average velocity, maximum velocity, and cross-section area were measured. Results: As a result of the case-by-case comparison, the error rate was less than 5%. There was no significant difference (p > 0.05). Conclusion: It is expected that this result will be useful for acquiring blood flow information in clinical practice.

맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발 (Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity)

  • 최정현;조욱현;박준호;김남훈;성향숙;조종만
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

심장 치료 전후의 혈압 측정 인자의 변화에 관한 연구 (A Study on the Changes of Blood Pressure Measurement Factors Before and After Heart Treatment)

  • 최원석
    • 융합신호처리학회논문지
    • /
    • 제22권2호
    • /
    • pp.51-56
    • /
    • 2021
  • 상완 수축기 혈압과 맥압은 50세 이상의 개인에서 심혈관 질환의 예측 인자이다. 강성이 증가함에 따라 수축기 후기의 반사 진폭과 압력이 증가하여 좌심실 부하와 심근 산소 요구량이 증가한다. 따라서 강성이 혈압에 미치는 영향을 연구 할 필요가 있다. 본 연구에서는 약물 복용 전후에 혈압 맥파를 측정하고, 심부전 환자에서 심근 심장 이식 전후에 혈압 맥파를 측정하였다. Windkessel 모델의 R, L 및 C 구성 요소 간의 상관관계는 혈압을 높임으로써 추정되었다. 커브 피팅 방법을 사용하여 Windkessel 모델의 매개 변수를 모델링 한 결과 혈압의 증가와 수축기 상승 시간의 감소는 RLC Windkessel 모델의 L 성분이 증가했기 때문이다. 혈관의 다양한 기계적 특성 중에 높은 BP 파형에 영향을 미치는 가장 중요한 매개 변수는 실험결과로 이너턴스인 것을 증명하였다.

Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers

  • Ro, Younghye;Choi, Woojae;Hong, Leegon;Kim, Eunkyung;Choe, Eunhui;Kim, Danil
    • Journal of Veterinary Science
    • /
    • 제23권4호
    • /
    • pp.60.1-60.6
    • /
    • 2022
  • Background: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. Objectives: This study aimed to evaluate the correlations among these three analyzers. Methods: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. Results: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). Conclusions: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.