• Title/Summary/Keyword: Blood Flow Rate

Search Result 487, Processing Time 0.034 seconds

Clinical Characteristics of Patients with Taste Disorders (미각 장애 환자의 임상적 특성에 관한 연구)

  • Lee, Eun-Jin;Park, Won-Kyu;Nam, Jin-Woo;Yun, Jong-Il;Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.341-351
    • /
    • 2009
  • There is tremendous variability in the ways patients present with taste problems. Because of complex and multifactorial etiological background, it is not simple to evaluate patients with taste disorders. Accurate assessment of patients' status by prudent, thorough history taking and symptom analysis is the most essential for exact diagnosis of taste disorders. The aim of this study was to investigate the clinical characteristics of patients with taste problems as a primary complaint. Consecutive series of 50 patients (12 males and 38 females, mean age $53.6\;{\pm}\;14.7$ years) were included for the present study. All subjects were requested to complete a comprehensive questionnaire. Clinical evaluation procedures included oral examination, interview, questionnaire analysis, panoramic radiography, blood test and measurement of salivary flow rate. The obtained results were as follows: 1. Among the patients, 36 patients (72%) complained of oral mucosal pain or burning sensation. Of these patients, 18 patients (36%) were diagnosed as burning mouth syndrome. 2. Nineteen patients (38%) complained of subjective oral dryness. The flow rate of unstimulated whole saliva was less than 0.1 mL/min in 14 patients (28%) and 17 (34%) had a stimulated whole salivary flow rate of less than 0.5 mL/min. 3. Among the types of taste disorders, hypogeusia, the most frequently reported, was found in 25 patients (50%), dysgeusia in 18 patients (36%), phantogeusia in 15 patients (30%), hypergeusia in 10 patients (20%), and ageusia in 5 patients (10%). Nineteen patients (38%) reported more than one type of taste disorder and the most frequent combination was dysgeusia + hypogeusia (n=6, 12%). 4. Based on data from the medical and dental histories and examinations, the patients were assigned to 12 probable causal categories. Taste disorders due to oral mucosal diseases and idiopathic taste disorder were the most frequent (n=9; 18%, each), followed by psychogenic taste disorder (n=8; 16%), drug-induced taste disorder (n=7; 14%), and taste disorder due to dry mouth (n=6; 12%). These 5 categories of taste disorder accounted for 78% of all cases in this study.

Influence of Intracerebroventricular Yohimbine on the Renal Function of the Rabbit (가토 신장기능에 미치는 측뇌실내 Yohimbine의 영향)

  • Kook, Young-Johng;Kim, Kyung-Keun;Kim, Sei-Jong
    • The Korean Journal of Pharmacology
    • /
    • v.21 no.2
    • /
    • pp.119-127
    • /
    • 1985
  • The renal function is under regulatory influence of the central nervous system, mainly through activation of sympathetic nerve to the kidney, and it was recently reported that clonidine, an agonist to ${\alpha}_2$-adrenoceptors, induces diuresis and natriuresis when injected directly into a lateral ventricle of the rabbit brain (i.c.v.). This study was undertaken, therefore, to obtain further information as to the role of the central ${\alpha}_2$-adrenoceptors in regulating renal function, by observing the effects of i.c.v. yohimbine, a specific antagonist of adrenoceptors of ${\alpha}_2$-type, on the rabbit renal function, and to elucidate the mechanism involved in it. With 10 ${\mu}g/kg$ i.c.v. of yohimbine sodium excretion transiently increased along with increasing tendency of urine flow, renal plasma flow and glomerular filtration rate. These responses decreased with increasing doses. With 100 and 300 ${\mu}g/kg$ i.c.v. marked antidiuresis and antinatriuresis as well as profound decreases of renal perfusion and glomerular filtration were noted. Systemic blood pressure transiently increased. In reserpinized rabbits, 100 ${\mu}g/kg$ yohimbine i.c.v. did not produce any significant changes in urine flow, sodium excretion as well as in renal hemodynamics. The pressor response was also abolished. In preparations in which one kidney was denervated and the other left intact as control, i.c.v. yohimbine elicited typical antidiuretic antinatriuretic response in the innervated control kidney, whereas the denervated experimental kidney responded with marked diuresis and increases in excretory rates of sodium and potassium and in osmolar clearance in spite of absence of increased filtration and perfusion . Systemic blood pressure responded as in the normal rabbits. These observations indicate that i.c.v. yohimbine affects renal function in dual ways in opposite directions, the first being the antidiuretic antinatriuretic effects which results from decreased renal perfusion and glomerular filtration due to sympathetic activation and which is predominantly expressed in the normal rabbits, and the second less apparent effect being the diuretic and natriuretic action which is not mediated by nerve pathway but brought about by some humoral mechanism and which is effected by decreased sodium reabsorption in the tubules, possibly of the proximal portion.

  • PDF

The Effect of the Histidine-Tryptophan-Ketoglutarate (HTK) Solution on Myocardial Protection in Isolated Rat Heart (흰쥐의 적출심장에서 HTK 용액의 심근보호 효과)

  • 송원영;장봉현;김규태
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.632-643
    • /
    • 2004
  • Background: The Histidine-Tryptophan-Ketoglutarate (HTK) solution has been shown to provide the excellent myocardial protection as a cardioplegia. The HTK solution has relatively low potassium as an arresting agent of myocardium, and low sodium content, and high. concentration of histidine biological buffer which confer a buffering capacity superior to that of blood.. Since HTK solution has an excellent myocardial protective ability, it is reported to protect myocardium from ischemia for a considerable time (120 minutes) with the single infusion of HTK solution as a cardioplegia. The purpose of this study is to evaluate the cardioprotective effect of HTK solution on myocardium when the ischemia is. exceeding 120 minutes at two different temperature (10 to 12$^{\circ}C$, 22 to 24$^{\circ}C$) using the Langendorff apparatus, Material and Method: Hearts from Sprague-Dawley rat, weighing 300 to 340 g, were perfused with Krebs-Henseleit solution at a perfusion pressure of 100 cm $H_2O$. After the stabilization, the heart rate, left ventricular developed pressure (LVDP), and coronary flow were measured. Single dose of HTK solution was infused into the ascending aorta of isolated rat heart and hearts were preserved at four different conditions. In group 1 (n=10), hearts were preserved at deep hypothermia (10∼12$^{\circ}C$) for 2 hours, in group 2 (n=10), hearts were preserved at moderate hypothermia (22∼24$^{\circ}C$) for 2 hours, in group 3 (n=10), hearts were preserved at deep hypothermia for 3 hours, and in group 4 (n=10), hearts were preserved at moderate hypothermia for 3 hours. After the completion of the preservation, the heart rate, left ventricular developed pressure, and coronary flow were measured at 15 minutes, 30 minutes, and 45 minutes after the initiation of reperfusion to assess the cardiac function. Biopsies were also done and mitochondrial scores were counted in two cases of each group for ultrastructural assessment. Result: The present study showed that the change of heart rate was not different between group 1 and group 2, and group 1 and group 3. The heart rate was significantly decreased at 15 minutes in group 4 compared to that of group 1 (p<0.05 by ANCOVA). The heart rate was recovered at 30 minutes and 45 minutes in group 4 with no significant difference compared to that of group 1. The decrease of LVDP was significant at 15 minutes, 30 minutes and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). Coronary flow was significantly decreased at 15 minutes, 30 minutes, and 45 minutes in group 4 compared to that of group 1 (p < 0.001 by ANCOVA). In ultrastructural assessment, the mean myocardial mitochondrial scores in group 1, group 2, group 3, and group 4 were 1.02$\pm$0.29, 1.52$\pm$0.26, 1.56$\pm$0.45, 2.22$\pm$0.44 respectively. Conclusion: The HTK solution provided excellent myocardial protection regardless of myocardial temperature for 2 hours. But, when ischemic time exceeded 2 hours, the myocardial hemodynamic function and ultrastructural changes were significantly deteriorated at moderate hypotherma (22∼ 24$^{\circ}C$). This indicates that it is recommended to decrease myocardial temperature when myocardial ischemic time exceeds 2 hours with single infusion of HTK solution as a cardioplegia.

Studies on the Hemodynamic Changes in Cirrhosis of the Liver (간경변증(肝硬變症)에서의 혈역학적(血力學的) 변화(變化)에 관(關)한 연구(硏究))

  • Kim, Jung-Il;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.11-27
    • /
    • 1970
  • Cardiac output, plasma volume and renal plasma flow were determined to evaluate hemodynamic changes in 29 patients with cirrhosis of the liver. The results obtained were as follows. 1. The mean plasma volume was 3793+895ml and it was significantly higher than the normal controls. The mean blood volume ($5266{\pm}1222ml$) and blood volume per kg body weight ($95.7{\pm}23.41ml$) were also increased significantly. The mean plasma volume per kg body weight ($69.1{\pm}19.1ml$) showed increased tendency and the mean difference between blood volume and plasma volume per kg body weight ($26.4{\pm}7.05ml$) was in lower limit of normal range. 2. The mean cardiac output was $7708{\pm}2652ml/min$ and it was significantly increased. The mean cardiac index ($4924{\pm}1998ml/min/M^2$), stroke volume ($96.2{\pm}34.2ml/beat$), stroke index ($62.3{\pm}27.34ml/M^2$) and fractional cardiac index ($1.54{\pm}0.577$) were also increased significantly. The mean total -peripheral resistance was $1664{\pm}753.8\;dynes\;sec\;cm^{-5}M^2$ and it was significantly lower than the normal controls. 3. The mean renal plasma flow was $537{\pm}146.8ml/min/1.73M^2$ and it was normal to decreased tendency. The mean endogenous creatinine clearance ($66.7{\pm}23.0ml/min/1.73M^2$) was significantly decreased. Filtration fraction was variable, but it was slightly lower than normal in most cases. The mean renal fraction of cardiac output ($11.4{\pm}6.27%$) was relatively decreased. 4. Although renal plasma flow was normal or decreased in general, it was definitely diminished in patients with creatinine clearance less than $60ml/min/1.73M^2$, resistant ascites, and signs of azotemia (elevated BUN and serum creatinine). 5. Diminished glomrular filtration rate with low filtration fraction and decreased renal fraction of cardiac output observed strongly supported increased renal afferent arteriolar resistance. 6. Renal circulatory impairment preceded azotemia or oroliguria in cirrhosis. 7. Clinical findigns and liver function were not correlated with hemodynamic changes, except for esophageal varices associated with high cardiac output obsedved. 8. No definite correlation of renal hemodynamics with plasma volume or cardiac output was found.

  • PDF

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

Effects of Differential Distribution of Microvessel Density, Possibly Regulated by miR-374a, on Breast Cancer Prognosis

  • Li, Jian-Yi;Zhang, Yang;Zhang, Wen-Hai;Jia, Shi;Kang, Ye;Tian, Rui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.1715-1720
    • /
    • 2013
  • Background: The discovery that microRNAs (miRNAs) regulate proliferation, invasion and metastasis provides a principal molecular basis of tumor heterogeneity. Microvessel distribution is an important characteristic of solid tumors, with significant hypoxia occurring in the center of tumors with low blood flow. The distribution of miR-374a in breast tumors was examined as a factor likely to be important in breast cancer progression. Methods: Breast tissue samples from 40 patients with breast cancer were classified into two groups: a highly invasive and metastatic group (HIMG) and a low-invasive and metastatic Group (LIMG). Samples were collected from the center and edge of each tumor. In each group, six specimens were examined by microRNA array, and the remaining 14 specimens were used for real-time RT-qPCR, Western blot and immunohistochemical analyses. Correlation analysis was performed for the miRNAs and target proteins. Follow-up was carried out during 28 months to 68 months after surgery, and survival data were analyzed. Results: In the LIMG, the relative content of miR-374a was lower in the center of the tumor than at its edge; in the HIMG, it was lower at the edge of the tumor, and miR-374a levels were lower in breast cancer tissues than in normal tissues. There was no difference between VEGF-A and VCAM-1 mRNA levels at the edge and center of the tumor; however, we observed a significant difference between VEGF-A and VCAM-1 protein expression levels in these two regions. There was a negative correlation between miR-374a and target protein levels. The microvessel density (MVD) was lower in the center of the tumor than at its edge in HIMG, but the LIMG vessels were uniformly distributed. There was a significant positive correlation between MVD and the number of lymph node metastases (Pearson correlation, r=0.912, P<0.01). The median follow-up time was 48.5 months. LIMG had higher rate of disease-free survival (100%, P=0.013) and longer median survival time (66 months) than HIMG, which had a lower rate of 75% and shorter median survival time (54 months). Conclusions: Our data demonstrated miR-374a to be differentially distributed in breast cancer; VEGF-A and VCAM-1 mRNA had coincident distribution, and the distribution of teh respective proteins was uneven and opposite to that for the miR-374a. These data might explain the differences in the distribution of MVD in breast cancer and variation in breast cancer prognosis.

Ovarian Features after 2 Weeks, 3 Weeks and 4 Weeks Transdermal Testosterone Gel Treatment and Their Associated Effect on IVF Outcomes in Poor Responders

  • Kim, Chung-Hoon;Ahn, Jun-Woo;Moon, Jei-Won;Kim, Sung-Hoon;Chae, Hee-Dong;Kang, Byung-Moon
    • Development and Reproduction
    • /
    • v.18 no.3
    • /
    • pp.145-152
    • /
    • 2014
  • This study was performed to investigate the effect of of transdermal testosterone gel (TTG) on controlled ovarian stimulation (COS) and IVF outcomes and ovarian morphology according to pretreatment duration in poor responders. A total of 120 women were recruited for this pilot study. They were randomized into control, 2 weeks, 3 weeks or 4 weeks TTG treatment groups. For three TTG treatment groups, 12.5 mg TTG was applied daily for 2 weeks, 3 weeks or 4 weeks in preceding period of study stimulation cycle. After 3 weeks of TTG pretreatment, significant increase of antral follicle count (AFC) and significant decreases of mean follicular diameter (MFD) and resistance index (RI) value of ovarian stromal artery were observed (p=0.026, p<0.001, p<0.01, respectively). The total dose of rhFSH administered for COS significantly decreased after 3 and 4 weeks TTG treatment both compared with control group (p<0.001, p<0.001). The numbers of oocytes retrieved and mature oocytes were significanty higher in 3 and 4 weeks TTG treatment groups than control group (p<0.001, p<0.001 in the number of oocytes retrieved; p<0.001, p<0.001 in the number of mature oocytes). The clinical pregnancy rate and live birth rate were increased only in 4 weeks TTG treatment group compared with control group (p=0.030 and p=0.042, respectively). These data demonstrated that TTG pretreatment for 3 to 4 weeks increases AFC and ovarian stromal blood flow, thereby potentially improving the ovarian response to COS and IVF outcome in poor responders undergoing IVF/ICSI.

Development of a Pacemaker with a Ventricular Assist Device for End-Stage Heart Failure Patients (말기 심질환 환자를 위한 심실보조장치용 심박조율기의 개발)

  • Kim, Yoo-Seok;Park, Sung-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1205-1211
    • /
    • 2011
  • In this paper, we developed a pacemaker that can increase the efficacy of a left ventricular assist device (LVAD) and increase the survival rate for patients suffering end-stage heart failure. Because LVAD patients can experience arrhythmia, the pacemaker incorporated into the LVAD has the important role of sustaining sufficient blood circulation during arrhythmia. The electrode of the pacemaker is located at the apex of the left ventricle, where the VAD's inlet cannula is connected. This is efficient placement, in that the electrode can transmit electrical stimulation directly to the Purkinje fibers of the myocardium. The pacemaker can change the stimulation rate from 0 bpm to 191.4 bpm when a button is pressed on the external control module, and the pacemaker normally stimulates the heart at 60 bpm with 0.25 J of energy. We performed animal experiments to evaluate the performance and reliability of the combination of the LVAD and pacemaker. At pacemaker stimulation rates of 86.4 bpm, 100.2 bpm, 126.6 bpm, we recorded the ECGs, aortic pressures, and flow rates to analyze the heart loads.

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF