• Title/Summary/Keyword: Blood Analysis

Search Result 4,870, Processing Time 0.038 seconds

Diagnosis parameters extraction by correlativity analysis of blood pressure(BP) and head blood pressure(HBP) and Development of multi-function automatic blood pressure monitor (상완혈압과 두부혈압의 상관성 분석에 의한 진단요소 추출과 다기능 전자혈압계의 개발)

  • 이용흠;고수복;정동명
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.58-67
    • /
    • 2003
  • Many adult diseases(cerebral apoplexy, athymiait, etc.) result from hypertension, blood circulation disturbance and increment of HBP. In early diagnosis of these diseases, MRI, X-ray and PET have been used rather aim for treatment than prevention of a disease. Since, cerebral apoplexy and athymiait have been caused to the regular/irregular persons, it is very important to measure HBP which has connection with cerebral blood low state. HBP has more diagnosis elements than that of BP. So, we can diagnose accurate hypertension by measuring of HBP. But, existing sphygmomanometers and automatic BP monitors can not measure HBF, and can not execute complex function(measuring of BP/HBP, blood flow improvement). The purpose of this paper is to develop the system and algorithm which can measure BP/HBP for accurate diagnosis. Also, we extracted diagnosis factors by the correlativity analysis of BP/HBP. The maximum pressure of HBP corresponds to 62% that of BP, the minimum pressure of HBP corresponds to 46% that of BP. Therefore, we developed the multi function automatic blood pressure monitor which can measure BP/HBP and improve cerebral blood flow state.

The Analysis on Related Factors of the Aged Examines Who Get Diagnosed in Their Climacteric Period According to Sex (생애전환기 건강진단 노인수검자의 성별에 따른 관련 요인분석)

  • Keum, Eun-Sun;Seo, Bu-Il
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.1
    • /
    • pp.119-134
    • /
    • 2010
  • Objectives & Method:Based on the statistic from January 2008 to December 2008 include 66-year-old 375 people (159 men, 216 women) who got examined in National Health Insurance Corporation, this study set a goal to establish a new health index by analyzing the relation between the cardio-cerebra vascular disease and risk factor such as obesity, smoking, exercise, alcohol consumption, blood pressure, blood sugar and cholesterol. Results:1) Examine results, health status according to gender;People who are diagnosed as abnormal health status have higher risk for both men and women. As for the detailed diseases, high blood pressure was highest followed by hyperlipidemia and obesity. In case of the women, 96.3% in bone mineral density was highest. 2) Correlation of disease and health risk factors based on gender;Correlation of disease according to gender in the obesity(p<0.001), lipid abnormalities(p<0.001), kidney diseases(p<0.001), chest diseases(p<0.05), osteoporosis(p<0.001) showed a statistically significant difference. The analysis showed that the men have more obesity and lipid abnormalities as well as thoracic disease than the women, but the women have more kidney disease than the men. As for the osteoporosis examine which is conducted only for the women, most of the women were abnormal even though it cannot compare the result according to gender. Obesity(p<0.001), alcohol(p<0.001), smoking(p<0.001) and LDLcholesterol(p<0.001) showed statistical correlation between gender and health risk factor. And only high blood pressure(p<0.001) showed a statistical correlation between gender and risk of cardio-cerebra vascular disease. 3) Risk of cardio-cerebra vascular disease related to health risk factor characteristic;Obesity assessment(p<0.001), alcohol(p<0.05), smoking(p<0.05), blood pressure(p<0.001), glucose(p<0.001) showed correlation between health risk factor and stroke. Drinking(p<0.001), smoking(p<0.05), exercise(p<0.001), blood pressure(p<0.001), LDL cholesterol(p<0.001) showed health risk factor and myocardial infarction. Obesity assessment(p<0.001), smoking(p<0.05), blood pressure(p<0.001), glucose(p<0.001) and showed correlation between health risk factor and diabetes. Obesity assessment(p<0.001), blood pressure(p<0.001) showed correlation between health risk factor and high blood pressure. Conclusion:Therefore, we have to take one step farther after the health examination. In order to prevent and reduce the risk of disease, people have to understand their health status exactly first, and correct their habit with recognizing the amount of risk related to cardio-cerebra vascular disease.

The Analysis of Hospital Characteristics affecting Blood Transfusion to the patients under Knee or Hip Total Replacement Arthroplasty (슬관절과 고관절 전치환술 환자의 수혈에 영향을 미치는 병원특성 요인 분석)

  • Oh, Ji-Young;Kim, Sang-Mi;Lee, Seong-A
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4031-4039
    • /
    • 2015
  • The problems related with blood supply shortage and the stability of blood transfusion are on the rise, as it is expected that the blood doners will decrease but the blood use amount for aged population will increase, owing to low birth and aged population increase. The purpose of this study is to analyze the hospital characteristics which affect patients receiving and non-receiving blood transfusion for the knee and hip total replacement arthroplasty. Data were collected from Health Insurance Review and Assessment Service's 2011 sample data, and 5,370 inpatients were abstracted from them. Logistic regression analysis was performed, using SPSS 20. Independent variables used are hospital characteristics variables and patient characteristics variables. Hospital characteristics variables are hospital type, ownership, residence and the number of usable beds, and patient characteristics variables are gender, age, severity, type of anesthesia, main diagnosis, whether or not of anemia and insurance class. At the result of this study, it was found that hospital type, region, gender, age, severity, main diagnosis and whether or not of anemia were the factors that mostly affected the blood transfusion for knee arthroplasty. And hospital type, residence, gender, age, severity, type of anesthesia and whether of not of anemia were the factors that mostly affected the blood transfusion for hip arthroplasty. In addition to that, it is expected that this research which analyzed the present state of blood transfusion and its influence factors are cost effective, and would make a good use of preliminary data for good quality of medical service.

Dark-Blood Computed Tomography Angiography Combined With Deep Learning Reconstruction for Cervical Artery Wall Imaging in Takayasu Arteritis

  • Tong Su;Zhe Zhang;Yu Chen;Yun Wang;Yumei Li;Min Xu;Jian Wang;Jing Li;Xinping Tian;Zhengyu Jin
    • Korean Journal of Radiology
    • /
    • v.25 no.4
    • /
    • pp.384-394
    • /
    • 2024
  • Objective: To evaluate the image quality of novel dark-blood computed tomography angiography (CTA) imaging combined with deep learning reconstruction (DLR) compared to delayed-phase CTA images with hybrid iterative reconstruction (HIR), to visualize the cervical artery wall in patients with Takayasu arteritis (TAK). Materials and Methods: This prospective study continuously recruited 53 patients with TAK (mean age: 33.8 ± 10.2 years; 49 females) between January and July 2022 who underwent head-neck CTA scans. The arterial- and delayed-phase images were reconstructed using HIR and DLR. Subtracted images of the arterial-phase from the delayed-phase were then added to the original delayed-phase using a denoising filter to generate the final-dark-blood images. Qualitative image quality scores and quantitative parameters were obtained and compared among the three groups of images: Delayed-HIR, Dark-blood-HIR, and Dark-blood-DLR. Results: Compared to Delayed-HIR, Dark-blood-HIR images demonstrated higher qualitative scores in terms of vascular wall visualization and diagnostic confidence index (all P < 0.001). These qualitative scores further improved after applying DLR (Dark-blood-DLR compared to Dark-blood-HIR, all P < 0.001). Dark-blood DLR also showed higher scores for overall image noise than Dark-blood-HIR (P < 0.001). In the quantitative analysis, the contrast-to-noise ratio (CNR) values between the vessel wall and lumen for the bilateral common carotid arteries and brachiocephalic trunk were significantly higher on Dark-blood-HIR images than on Delayed-HIR images (all P < 0.05). The CNR values were significantly higher for Dark-blood-DLR than for Dark-blood-HIR in all cervical arteries (all P < 0.001). Conclusion: Compared with Delayed-HIR CTA, the dark-blood method combined with DLR improved CTA image quality and enhanced visualization of the cervical artery wall in patients with TAK.

Assessments of baroreflex sensitivity through the closed-loop feedback model between RR fluctuation and arterial blood pressure fluctuation (RR간격변동과 열합변동간의 폐루프 귀환 모델을 통한 압수용체반사감도의 평가)

  • 신건수;최석준;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1643-1646
    • /
    • 1997
  • In this study, the method is proposed, which enable us to noninvasively assess baroreflex sensitivity through the closed-loop feedback modle between RR flucturarion and arterial blood pressure fluctuation. The proposed indexes of baroreflex sensitivity, BRS$_{LF}$와 BRS$_{HF}$ are calculated by the modulus (or gain) of the transfer function between fluctuatuons in blood pressure and RR interval in the LF band HF band, where the coherence is more than 0.5 to evaluate the performance of the proposed method, it is applied to various cardiovascular variability signals obtained form subjects under the submaximal ecericse on bicycle ergometner. In result it is concluded that the proposed method can noninvasively assess the baroreflex sensitivity.ty.

  • PDF

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

  • Sung, Kun-Hyuk;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • A numerical analysis is performed to investigate the effect of rotation on the blood flow characteristics with four different angular velocities. The artery has a cylindrical shape with 50% stenosis rate symmetrically distributed at the middle. Blood flow is considered a non-Newtonian fluid. Using the Carreau model, we apply the pulsatile velocity profile at the inlet boundary. The period of the heart beat is one second. In comparison with no-rotation case, the flow recirculation zone (FRZ) contracts and its duration is reduced in axially rotating artery. Also wall shear stress is larger after the FRZ disappears. Although the geometry of artery is axisymmetry, the spiral wave and asymmetric flow occur clearly at the small rotation rate. It is caused that the flow is influenced by the effects of the rotation and the stenosis at same time.

A Study on the Feature Region Segmentation for the Analysis of Eye-fundus Images (안저영상 해석을 위한 특징영역의 분할에 관한 연구)

  • 강전권;한영환
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.121-128
    • /
    • 1995
  • Information about retinal blood vessels can be used in grading disease severity or as part of the process of automated diagnosis of diseases with ocular menifestations. In this paper, we address the problem of detecting retinal blood vessels and optic disk (papilla) in eye-fundus images. We introduce an algorithm for feature extraction based on Fuzzy Clustering algorithm (fuzzy c-means). A method of finding the optic disk (papilla) is proposed in the eye-fundus images. Additionally, the inrormations such as position and area of the optic disk are extracted. The results are compared to those obtained from other methods. The automatic detection of retinal blood vessels and optic disk in the eye-rundus images could help physicians in diagnosing ocular diseases.

  • PDF

A Study on Noise Exposure Dose and Blood Pressure in an Automobile (모 자동차 공장의 소음폭로와 혈압에 관한 연구)

  • 김성천
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.48-53
    • /
    • 1991
  • This study was carried out to investigate age, noise intensity, work period, hearing loss at frequencies, hypertension and to examine correlation of the total quantity of noise exposure(Dose) and blood pressure (Response) in the auto industry during May 1987-December 1987. To perform this study 65 workers were tested. Results of this study were as follows: 1. In frequency analysis, the CS-dip phenomenon occurred around 4000 Hz. 2. Between under of ten years group and over of ten years group, average hearing loss value was statitically significant (P < 0.05). 3. The prevalence of hypertension of 65 workers was 7.84% . 4. At 90dB(A) over and 10 years under and workers in the 20's group, the total quantity of noise exposure (Dose) and systolic blood pressure (Response) were statistically significant (P < 0.05). 5. At under 10 years of work period group, the total quantity of noise exposure(Dose) and diastolic blood pressure (Response) were statistically significant(r =0.234, P < 0.1).

  • PDF

The Study on ${\ulcorner}YuLongFu{\lrcorner}$ (2) (옥룡부에 대한 연구(2))

  • Bang, Jung-Kyun;Jang, Hyun-Jun;Lee, Joon-Moo
    • Korean Journal of Acupuncture
    • /
    • v.24 no.2
    • /
    • pp.19-43
    • /
    • 2007
  • Objectives : The aim of this study was to analyse the symptoms of a disease and to elucidate the meaning and rationale of point selection in YuLongFu. Methods : We translated YuLongFu into Korean and analyzed symptoms based upon a comparison of YuLongFu with YuLongGe. The meaning and rationale of point selection in YuLongFu was then inferred from the analysis above. Results and Conclusions : Total 84 acupoints were used in YuLongFu. Moxibustion and pricking blood therapy were used twice. Generally, threre are a lot of diseases caused by stagnation of Qi and blood in YuLongFu. Point selection, therefore, was usually aimed at promoting flow of Qi and blood.

  • PDF

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.