• Title/Summary/Keyword: Blood Analysis

Search Result 4,899, Processing Time 0.033 seconds

Extraction of Blood Flow of Brachial Artery on Color Doppler Ultrasonography by Using 4-Directional Contour Tracking and K-Means Algorithm (4 방향 윤곽선 추적과 K-Means 알고리즘을 이용한 색조 도플러 초음파 영상에서 상환 동맥의 혈류 영역 추출)

  • Park, Joonsung;Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1411-1416
    • /
    • 2020
  • In this paper, we propose a method of extraction analysis of blood flow area on color doppler ultrasonography by using 4-directional contour tracking and K-Means algorithm. In the proposed method, ROI is extracted and a binarization method with maximum contrast as a threshold is applied to the extracted ROI. 4-directional contour algorithm is applied to extract the trapezoid shaped region which has blood flow area of brachial artery from the binarized ROI. K-Means based quantization is then applied to accurately extract the blood flow area of brachial artery from the trapezoid shaped region. In experiment, the proposed method successfully extracts the target area in 28 out of 30 cases (93.3%) with field expert's verification. And comparison analysis of proposed K-Means based blood flow area extraction on 30 color doppler ultrasonography and brachial artery blood flow ultrasonography provided by a specialist yielded a result of 94.27% accuracy on average.

A Study on Concentrations of Heavy Metal in Blood and Urine of Local Area in Korea (국내 일부 지역주민의 혈액과 요중 중금속 농도에 관한 연구)

  • Im, Ji-Young;Chung, Eun-Kyung;Park, Hee-Jin;Yu, Seungdo;Jang, Bong-Ki;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.59-72
    • /
    • 2013
  • The purpose of this study is to assess the effects of heavy metal concentrations in the blood and urine of the general population. This research had been conducted from April to December 2008, studying 545 residents of Daejeon and Chungcheong Province. Through the concentrations of heavy metals(Pb, Cd, Hg, As, Mn) in the biota samples and questionnaires, the residents heavy metal exposure level and the influential factors according to personal characteristics or lifestyle were evaluated. As to the heavy metal concentration in the blood and urine of the comparing region, were As and Mn statistically significant(p<0.01, p<0.05). Blood lead and urinary mercury concentrations were higher in males than females. The heavy metal concentration for each age group increased blood mercury. The concentration of all heavy metals were higher in the drinkers than in the non-drinkers. Blood lead and mercury concentrations were higher in the smokers than in the non-smokers, but the urinary cadmium, arsenic and blood manganese was higher in the non-smokers than in the smokers. As to the blood lead and urinary cadmium concentration according to the food preference fish showed high concentration. To clarify the factors affecting the heavy metal concentration in biota among subjects multiple regression analysis was conducted. As a results, it turned out that as to lead content in blood, sex, age and smoking have influence on the subjects with explanatory adequacy of 14.0 %. These results demonstrated that the factors affected the concentrations of heavy metals in blood and urine. The results of this study could be used as the foundational data for setting the health risk assessment.

Life Styles and the Blood Cadmium Concentration in Korean Adults (한국 성인에서의 생활행태와 혈중 카드뮴 농도)

  • Lee, Sang-Hyuk;Choi, Byung-Sun;Park, Jung-Duck
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.193-202
    • /
    • 2009
  • In this study, we analyzed the blood cadmium concentration in general population of Korea, and followed the analyses the relations with epidemiologic factors, life-style and body iron store. The geometric mean concentration of blood cadmium was 1.20 ${\mu}g/L$ in study subject, the level of blood cadmium was higher in female (1.27 ${\mu}g/L$) than in male (1.11 ${\mu}g/L$). The mean concentration of blood cadmium was the highest in coastal area (1.80 ${\mu}g/L$) and followed in urban (1.01 ${\mu}g/L$) and rural area (0.90 ${\mu}g/L$). The cadmium concentration in whole blood was increased with age-dependent pattern, such as 0.64 ${\mu}g/L$ in the below 30 years, 0.95 ${\mu}g/L$ in the 30~44 years, 1.28 ${\mu}g/L$ in the 45~59 years and 1.31 ${\mu}g/L$ in the over 60 years. The level of blood cadmium was higher in smokers than in non-smokers, but was not significant by alcoholic habit. The blood cadmium level was different from occupations, which was the highest in the fishers as 1.87 ${\mu}g/L$. The inversed relation was observed between blood cadmium and serum Fe, while was correlated positively with the ferritin level. In summary, the environmental exposure to cadmium in Korean is not so much compared to other countries, and the blood cadmium is influenced by genetic factors (age and sex), life-styles (dietary habit, occupation and smoking habit) and nutrition such as serum iron.

The association of total blood mercury levels and overweight among Korean adolescents: analysis of the Korean National Health and Nutrition Examination Survey (KNHANES) 2010-2013

  • Shin, Yi-Yeon;Ryu, In-Kyung;Park, Mi-Jung;Kim, Shin-Hye
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.4
    • /
    • pp.121-128
    • /
    • 2018
  • Purpose: Obesity has been associated with higher total blood mercury levels, based on animal studies; however, studies that focus on children and adolescents are lacking. We aimed to assess the association between total blood mercury levels and the incidence of overweight and abdominal obesity in Korean adolescents. Methods: The study population comprised 1,567 adolescents (793 boys and 774 girls; aged 10-19 years), who participated in the Korea National Health and Nutrition Examination Survey 2010-2013. We analyzed total blood mercury levels according to obesity status in all participants. Results: The geometric mean of total blood mercury levels was $1.93{\mu}g/L$. Participants with overweight ($2.20{\mu}g/L$) and obesity ($2.17{\mu}g/L$) had higher levels than those with normal weight ($1.86{\mu}g/L$, P<0.0001). The prevalence of overweight significantly increased with elevation of the total blood mercury quartile in both sexes. Increased incidence of abdominal obesity corresponding to increased total blood mercury level was observed in boys. After adjusting for covariates, those in the highest total blood mercury quartile were found to be at higher risk of overweight/obesity than those in the lowest quartile in both sexes (odds ratio [95% confidence interval]: boys, 3.27 [1.66-6.41]; girls, 1.90 [1.03-3.49]). The association between total blood mercury quartile and abdominal obesity was significant after controlling for covariates in boys (2.35 [1.05-5.24]). Conclusion: Our results suggest an association between total blood mercury levels and overweight in Korean adolescents.

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

Clinical Analysis on Relation Between Blood Flow and Patency af Arteriovenous Fistula for Hemodialysis (혈액투석을 위한 동정맥류 조성술후 혈류량과 동정맥루 개존에 관한 임상적 고찰)

  • 김창회
    • Journal of Chest Surgery
    • /
    • v.24 no.12
    • /
    • pp.1167-1172
    • /
    • 1991
  • Since March 1988 we have performed 133 arteriovenous fistulae for hemodialysis in 121 patients with chronic renal failure. Of the 133 cases of arteriovenous fistulae, follow-up evaluation was possible for 80 cases which performed in 69 patients. The relation between blood flow and patency rate and duration of arteriovenous fistula was examined. The overall 6 - 12 - 18 -, and 24 - month patency rates of arteriovenous fistulae were 82%, 64%a, 62%, and 57%, respectively. The maximum blood flow was 150 ~ 350ml /min[mean 217.1$\pm$44.27]. The patency duration was evaluated in patients divided into three groups owing to maximum blood flow through the fistulae. The range of maximum blood flow was 150 ~ 200ml /min for group A, 200 ~ 250ml /min for group B, and above 250ml /min for group C. The mean duration of the patency was 10.7$\pm$7.60 months in group A, 14.9$\pm$9.82 months in group B, and 21.6$\pm$11.16 months in group C[p<0 05]. With increased maximum blood flow, the duration of the patency was longer in group A than group B and C [r=0.39, p<0. 05]. The maintenance blood flow was 100 ~ 250ml /min[mean 179.2$\pm$37.26 ml/min]. When the maintenance blood flow was above 200ml /min, long-term patency rate was higher than the group below 200ml /min[r=0.48, p<0.01]. In the same range of blood flow, patency duration of the patients with using their own blood vessels were longer than the patients with using vascular graft for A-V fistula. We concluded that the patency of the arteriovenous fistulae was closely correlated with the blood flow through the fistulae.

  • PDF

Correlation of ketone bodies in blood and spleen

  • Sookyung Jeon;Sumin Lee;Wooyong Park;Chihyun Park;Minjung Kim
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.170-179
    • /
    • 2023
  • Starvation, diabetes, alcoholism and hypothermia cause ketoacidosis in the human body; therefore, the cause of death can be determined by analyzing ketone bodies in the blood of the deceased. In the case of decomposition of the cadaver, however, since collecting intact blood is impossible, ketone body analysis is performed using the spleen. However, the index for diagnosing ketoacidosis is based on blood concentration, and its correlation with ketone bodies present in the spleen remains unknown. In particular, since decomposition proceeds rapidly during summer, when temperature and humidity are high, understanding the correlation between ketone bodies in the blood and spleen is important to estimate the state at the time of death from a decaying body. Therefore, in the present study, the correlation between ketone bodies in the blood and spleen of the deceased was explored. Ketone bodies (beta-hydroxybutyric acid [BHB] and acetone) in the blood and spleen were analyzed and compared from autopsies (>100 mg·L-1 BHB, blood basis) conducted at the Daejeon Forensic Research Institute from June to December 2021. Moreover, the concentration of ketone bodies in the spleen juice and tissues was compared assuming the scenario of extreme decomposition. Ketone retention concentration in the blood and spleen was positively correlated, and the ratio of BHB concentration in the spleen to BHB concentration in the blood ranged from 0.52 to 1.08 (mean = 0.85 ± 0.12), although the ratio may vary depending on the degree of decomposition of the corpse.

An Analysis of the Blood Bank Whole Blood Inventory Control (혈액은행의 효율적 재고관리에 관한 연구)

  • O Hyeong-Jae
    • Journal of the military operations research society of Korea
    • /
    • v.8 no.2
    • /
    • pp.37-55
    • /
    • 1982
  • The whole blood inventory control model is developed, shown to provide an accurate representation of actual blood bank operations in Korea. The main difference of the blood bank situations between Korea and the United States is that about 50 percent of all bloods demanded, crossmatched, and held for a particular patient are eventually found not to be required for that patient in case of U.S. while in Korea the crossmatch test is not so significant and almost successful. Accordingly, the model in this paper is focused in seeking the minimum inventory level where neither shortage nor outdating bloods begin to occur, while the Jennings' model, developed in 1970 at MIT OR Center, is the inventory level somewhere between the inventory level 'band' where both shortage and outdating occur.

  • PDF

Dynamic Performance Evaluation of Blood Flow Simulator Based on Windkessel Models (공기압력모델에 기반한 혈류 시뮬레이터의 동적 특성 평가)

  • Chun, Sejong;Jin, Jonghan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.509-516
    • /
    • 2016
  • A blood flow simulator is one of the experimental devices used to better understand the cardiovascular system. Time-Domain analysis is not sufficient to understand the cardiovascular system because of the effects related to pulsating flows. Even when the mean pressure and mean flow rate of the blood flow simulators are satisfied, the dynamic properties can differ from the desired performance. In this paper, the Windkessel model, a well-known mathematical model of the cardiovascular system, was employed to obtain optimized pressure using initial values. The Windkessel parameters, including flow resistance, R, are expected to lead to a better understanding of the dynamic behavior of cardiovascular systems.

A Study on the Analysis of Oriental Functional Beverage and on the Blood Alcohol Concentration or Rat after Drinking Liquors (한방 기능성 음료분석 및 섭취후 흰쥐의 혈중 알코올 농도에 관한 연구)

  • 서광희;김성연
    • The Korean Journal of Food And Nutrition
    • /
    • v.14 no.3
    • /
    • pp.222-227
    • /
    • 2001
  • The production results of the oriental functional beverage, which is aimed at reducing the alcohol concentration in blood, are as follows. Different kinds of herb medicine ingredients were combined to achieve the balance between Yin And Yang. They were grouped according to their respective characteristics and extracted by heat, Then they were combined and produced following the most effective mixture ratio. The drink produced by this way consisted mainly of water, Sugar, mineral, protein and fiber were partially contained. Among the minerals, the proportion of calcium, potassium, magnesium was high and iron was also contained. This drink turned out to be effective in reducing the alcohol concentration in blood within a very short time when it was taken once after drinking and taken aging 30 minutes later, which would double the dosage. This result shows that development of such a functional beverage using the herbal medicine, At the same time it will play an important part in reducing the alcohol concentrate in blood after drinking liquors.

  • PDF