A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Estimation of Systolic Blood Pressure using PTTL (PTTL을 이용한 수축기 혈압추정)

  • Kil, Se-Kee;Kwan, Jang-Woo;Yoon, Kwang-Sub;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1095-1101
    • /
    • 2008
  • The desirable method to diagnose abnormal blood pressure is to measure and manage blood pressure continuously and regularly. However, the sphygmomanometers that are based on a cuff have faults in that they can not measure the blood pressure continuously and they cause an unpleasant feeling. Therefore, it is essential to develop a new measuring method that causes no pain and that can obtain blood pressure continuously without any unpleasant feeling. Thus, we propose here a regression method to estimate the systolic blood pressure by using the PTTL(pulse transit time on leg) with some body parameters which are chosen from the relational analysis with systolic blood pressure. The data we use to make the regression model were obtained in triplicate from each of 50 males who were from 18 to 35 years. And we made estimation experiments of blood pressure on 10 males who did not take part in the making the regression model. According to the results, the proposed method showed a mean error of 4.00 mmHg and the standard variance was 2.45 mmHg. When we comparing the results of the proposed method with the rule of American National Standards Institute of the Association of the Advancement of Medical Instruments(ANSI/AAMI), the results satisfied the rule of a mean error less than 5 mmHg and a standard variance less than 8 mmHg. Therefore we were able to validate the usefulness of the proposed method.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Analysis of Correlativity with Blood Pressure and Measurement of Brain Blood Pressure(BBP) (뇌혈압 측정과 상완 혈압의 상관성 분석)

  • Ko, Su-Bok;Lee, Yong-Heum;Kim, Sung-Gon;Jeong, Dong-Myong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.180-183
    • /
    • 2001
  • In modem city life, the citizen get insufficient exercise and has high levels of stress. Increased Stress causes such minor things as tiredness, disease and mental fatigue, and increase brain blood pressure too. In this paper trying to design the multi-functional blood pressure monitor with airo-dynamic brain hemokinesis improvement function. So this system have developed for the improvement of flows in the capillary blood vessel of head and limbs. Also This system is able to measure brain blood pressure(BBP) which need diagnosis circulation state of brain blood. So, we extracted correlativity of blood pressure(BP) and BBP through clinical experiment. We confirmed that compare factor of BP with BBP is more useful factors for diagnosis state of brain hemokinesis.

  • PDF

Automatic blood pressure measurement device using oscillometric method and Korotkoff sounds

  • Wei, Ran;Lim, Young Chul;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.1 no.2
    • /
    • pp.20-25
    • /
    • 2012
  • The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.

Heavy Metal as Risk Factor of Cardiovascular Disease - An Analysis of Blood Lead and Urinary Mercury (심혈관계 질환 위험요인으로서의 중금속 - 납과 수은에 대한 분석 -)

  • Kim, Dae-Seon;Yu, Seung-Do;Cha, Jung-Hoon;Ahn, Seung-Chul;Lee, Eun-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.38 no.4
    • /
    • pp.401-407
    • /
    • 2005
  • Objectives : We wanted to investigate the relationship between heavy metal, especially lead and mercury, to the blood pressure and cholesterol level in children. Methods : This study was undertaken in three primary schools and the study subjects were a total of 274 children. The lead in the blood and the urine mercury were analyzed by performing atomic absorption spectroscopy. Results : All of participants' blood lead levels and urine mercury concentrations were below the suggested level of concern according to the criteria of the CDC and ATSDR. We found no significant correlation between lead, mercury and the blood pressure. The blood lead level did not show any relationship with the blood pressure and cholesterol. However, the urine mercury levels were associated with the serum cholesterol. Conclusion : Our study suggests that mercury can induce an increase of cholesterol as a risk factor of myocardial infraction and coronary/cardiovascular disease.

Patient Outcomes according to Blood Glucose Level in Neonates with Cardiovascular Surgery (심혈관 수술 신생아의 혈당수준에 따른 환아 결과)

  • Hwang, Jeong-Hye;Park, Hyoung-Sook
    • Child Health Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.43-52
    • /
    • 2012
  • Purpose: The purpose of this study was to provide basic data for suitable neonate blood glucose maintenance by investigating and analyzing the blood glucose level of post cardiovascular surgery neonates in the ICU for the effect of blood glucose levels on the following outcomes; ICU stay, hospital stay, mechanical ventilation time, morbidity, and mortality. Methods: The participants were 143 neonates in the ICU after having had cardiovascular surgery. The design for this study was an investigation of the blood glucose levels of the neonates and retrospective analysis of patient outcomes according to blood glucose level. Results: The results for the neonate groups showed that the factors of hospital stay, ICU stay, mechanical ventilation time and mortality, for the group with a blood glucose level over 140 mg/dL were longer and higher than for the group with blood glucose of less than 100 mg/dL or the group between 100-139 mg/dL. Conclusion: The results of this study indicate that when caring for neonates after cardiovascular surgery, it is important to recognize the influence of blood glucose levels on patient outcomes like hospital days, ICU stay, length of time on mechanical ventilation and mortality. Further, care guidelines for neonates' glucose level management need to be developed.

Simultaneous measurements of red blood cell aggregation and blood viscosity in a slit rheometry with light transmission analysis (광 투사법을 이용한 슬릿 점도계에서의 적혈구 응집성 및 점도 측정에 관한 연구)

  • Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun;Suh, Jang-Su
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1678-1681
    • /
    • 2004
  • The light-transmission technique has been applied to a slit rheometer for measuring red blood cell aggregation as well as blood viscosity over a range of shear rates. For measurement of blood viscosity and aggregation, instantaneous pressure and transmit-light intensity are measured with time. Using a precision pressure measurement, one can determine the shear stress and shear rate. In addition, a transmitted light through a blood sample indicates degree of RBC aggregation. With abruptly flowing with high shear rate, RBCs rapidly disaggregate and the intensity of the transmitted light becomes low. When continuously flowing with decreasing shear rate, RBCs tend to re-aggregate and the corresponding transmit-intensity gradually increases with time. The light intensity as a degree of RBC aggregation is plotted against shear rate and compared with blood viscosity. The advantages of this design are dual measurement at a time, simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

Detecting Potassium Imbalance: Whole Blood vs. Serum (전혈과 혈청에서의 칼륨 이상소견 검사의 차이)

  • Cho, Young-Duck;Choi, Sung-Hyuk;Yoon, Young-Hoon;Park, Sang-Min;Kim, Jung-Youn;Lim, Chae-Seung
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.162-168
    • /
    • 2012
  • Background: Potassium, the most common cation in the intracellular space, plays a critical role in our physiology. Potassium imbalance may cause life-threatening problems, ranging from general weakness to cardiac arrest due to ventricular fibrillation. For emergency physicians, detection of such derangement within a short period of time is of critical importance. In this study, we wanted to determine whether analysis of whole blood samples can be used as a screening tool for potassium imbalance by comparative analysis of whole blood and serum samples. Methods: Two samples were drawn from 227 patients. The whole blood sample was taken from the radial artery and contained in a commercially available arterial blood collection syringe with a lithium-heparin coating. The serum sample was contained in a commercially available vacuum bottle in a non-additive silicone coated tube and transported to the laboratory. The study population was divided into three groups, patients with normal whole blood potassium, patients with decreased whole blood potassium, and patients with elevated whole blood potassium. Potassium levels for each group were coupled with serum potassium levels and compared. Results: No significant difference in potassium values was observed between whole blood and serum samples (P<0.05). Strong associations were observed among the three groups (normal range, hypokalemia, and hyperkalemia group). Compared to the normal group (r=0.851), the hyperkalemia group showed a stronger association between variables (r=0.897), and the hypokalemia group showed a weaker association (r=0.760). Their correlation coefficients were highly significant (P<0.05). Conclusion: Our study illustrates that point-of-care testing using whole blood with whole blood can be a reliable screening tool when treating patients with suspicious potassium abnormality, especially in hyperkalemia patients.

Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor (광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정)

  • Ko, J.I.;Jeong, I.C.;Lee, D.H.;Park, S.W.;Hwang, S.O.;Park, S.M.;Kim, G.Y.;Joo, H.S.;Yoon, H.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.