• Title/Summary/Keyword: Blind test

Search Result 418, Processing Time 0.024 seconds

Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction (이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Yoo, Seong-Yeon;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

Effects of Pressure Cooker Brand Awareness on the Consumer Acceptability of Cooked Rice

  • Kim, Dong-Hee;Kim, Hee-Sup
    • Food Quality and Culture
    • /
    • v.1 no.1
    • /
    • pp.34-39
    • /
    • 2007
  • The effects of pressure cooker brand awareness, in terms of rice cooking performance, were evaluated using consumer acceptability tests. A blind test was performed using rice samples cooked by 3 different pressure cookers without any brand information, and a brand awareness test followed with the same informed consumer panel. Overall acceptability, glossiness, stickiness, hardness, flavor, and color were evaluated and compared to determine whether or not there were changes on consumer choice for acceptability. Brand A and brand B were not significantly different in their overall acceptability, moisture content, flavor, or color (p > 0.05), but they were significantly different for glossiness, stickiness, and hardness. Brands A and C were significantly different for all the attributes (p < 0.05). In the brand awareness test, brands A and B were not significantly different in their liking scores for all the attributes (p > 0.05). Brand C had significantly lower liking scores for overall acceptability, glossiness, stickiness, hardness, and moisture content than the other brands (p < 0.05). When comparing the liking scores for all the attributes with those of the blind test, the scores of the brand awareness test were slightly higher. For brand A, there were changes in its liking scores for overall acceptability, flavor, and glossiness (p < 0.05). However, brands B and C had brand awareness effects for all the attributes (p < 0.05).

  • PDF

Japanese Vowel Sound Classification Using Fuzzy Inference System

  • Phitakwinai, Suwannee;Sawada, Hideyuki;Auephanwiriyakul, Sansanee;Theera-Umpon, Nipon
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.35-41
    • /
    • 2014
  • An automatic speech recognition system is one of the popular research problems. There are many research groups working in this field for different language including Japanese. Japanese vowel recognition is one of important parts in the Japanese speech recognition system. The vowel classification system with the Mamdani fuzzy inference system was developed in this research. We tested our system on the blind test data set collected from one male native Japanese speaker and four male non-native Japanese speakers. All subjects in the blind test data set were not the same subjects in the training data set. We found out that the classification rate from the training data set is 95.0 %. In the speaker-independent experiments, the classification rate from the native speaker is around 70.0 %, whereas that from the non-native speakers is around 80.5 %.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

A Randomized single blind controlled clinical trial on safety and efficacy of a Unani formulation (Itrifal-e-Sagheer) in dyslipidemia

  • Alam, Sazid;Alam, MD Anzar;Quamri, MA;Sofi, Ghulamuddin;Khan, Mohd. Qudratullah;Ansari, Shabnam
    • CELLMED
    • /
    • v.10 no.1
    • /
    • pp.8.1-8.7
    • /
    • 2020
  • Aim:'Itrifal-e-Sagheer', a compound Unani formulation has been indicated in disease conditions simulating dyslipidemia. The present study was done to substantiate the efficacy of 'Itrifal-e-Sagheer' in dyslipidemia on scientific parameters. Materials and methods: A randomized, single blind, controlled, clinical trial was carried out on 30 patients of dyslipidemia who were randomly allocated into test (n = 15) or control (n = 15) groups. The test drug, Itrifal-e-Sagheer and control drug, Abana® were given to respective group for 45 days along with lifestyle modification. Results: The test drug significantly alleviated the symptoms of subjective parameters (palpitation, breathlessness and weight gain) (p<0.05). There was statistically significant reduction in lipid profile of the patients in test group (p<0.05) than control drug treatment. Conclusion: The study evidenced that Itrifal-e-Sagheer is potentially effective and safe in the treatment of dyslipidemia. However, a multicentric study with robust study design is required to generalize the results.

NEW PHARMACOLOGICAL, CLINICAL, MICROBIOLOGICAL AND ANALYTICAL TESTS MADE WITH VARIOUS GINSENG PREFARATIONS OF THE WORLD MARKET

  • Rueckert Karl Heinz
    • Proceedings of the Ginseng society Conference
    • /
    • 1978.09a
    • /
    • pp.85-92
    • /
    • 1978
  • The aim of the double blind test was to assess the prophylactic and therapeutic efficacy of the preparation GINSANA, containing the standardized ginseng extract PHARMATON G115,. The determination was carried out with special emphasis on the following features : general physical condition, physical performance, mental performance, enjoyment of life/mood, concentration and memory, as well as sleeping habits. Sixty test persons took part in the study, men and women between the ages of 22 and 80. The 90-day test was carried out in the form of a double blind experiment. Experimental measurements were made and the persons were also questioned. The reaction time, the optical merging threshold, the coordination of both hands and the recovery quotients, as well as the recovery rates were analyzed. The results for the serum group were clearly better than those for the placebo group, particularly for the characteristics: general physical condition, physical performance and sleeping habits. The results of the test methods used, especially with regard to the reaction time, the coordination of both hands, the recovery quotient and the recovery period, permit the following conclusion to be drawn: when administered for several weeks, GINSANA has a positive action, in the sense of an activation of the entire personality by the ginseng glycosides contained in the standardized Extracts G115.

  • PDF

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

Comparison of ondansetron and granisetron for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia: a prospective, randomised, and double blind study

  • Savant, Kiran;Khandeparker, Rakshit Vijay Sinai;Berwal, Vikas;Khandeparker, Purva Vijay;Jain, Hunny
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.2
    • /
    • pp.84-89
    • /
    • 2016
  • Objectives: To compare the efficacy of intravenous ondansetron (4 mg, 2 mL) and granisetron (2 mg, 2 mL) for preventing postoperative nausea and vomiting (PONV) in patients during oral and maxillofacial surgical procedures under general anesthesia. Materials and Methods: A prospective, randomized, and double blind clinical study was carried out with 60 patients undergoing oral and maxillofacial surgical procedures under general anesthesia. Patients were divided into two groups of 30 individuals each. Approximately two minutes before induction of general anesthesia, each patient received either 4 mg (2 mL) ondansetron or 2 mg (2 mL) granisetron intravenously in a double blind manner. Balanced anesthetic technique was used for all patients. Patients were assessed for episodes of nausea, retching, vomiting, and the need for rescue antiemetic at intervals of 0-2, 3, 6, 12, and 24 hours after surgery. Incidence of complete response and adverse effects were assessed at 24 hours postoperatively. Data was tabulated and subjected to statistical analysis using the chi-square test, unpaired t-test, or the Mann-Whitney U-test as appropriate. A P-value less than 0.05 was considered statistically significant. Results: There was no statistically significant difference between the two groups for incidence of PONV or the need for rescue antiemetic. Both study drugs were well tolerated with minimum adverse effects; the most common adverse effect was headache. The overall incidence of complete response in the granisetron group (86.7%) was significantly higher than the ondansetron group (60.0%). Conclusion: Granisetron at an intravenous dose of 2 mg was found to be safe, well tolerated, and more effective by increasing the incidence of complete response compared to 4 mg intravenous ondansetron when used for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia. Benefits of granisetron include high receptor specificity and high potency, which make it a valuable alternative to ondansetron.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF