• 제목/요약/키워드: Bladder dose

검색결과 159건 처리시간 0.027초

Morphologic change of rectosigmoid colon using belly board and distended bladder protocol

  • Cho, Yeona;Chang, Jee Suk;Kim, Mi Sun;Lee, Jaehwan;Byun, Hwakyung;Kim, Nalee;Park, Sang Joon;Keum, Ki Chnag;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • 제33권2호
    • /
    • pp.134-141
    • /
    • 2015
  • Purpose: This study investigates morphologic change of the rectosigmoid colon using a belly board in prone position and distended bladder in patients with rectal cancer. We evaluate the possibility of excluding the proximal margin of anastomosis from the radiation field by straightening the rectosigmoid colon. Materials and Methods: Nineteen patients who received preoperative radiotherapy between 2006 and 2009 underwent simulation in a prone position (group A). These patients were compared to 19 patients treated using a belly board in prone position and a distended bladder protocol (group B). Rectosigmoid colon in the pelvic cavity was delineated on planning computed tomography (CT) images. A total dose of 45 Gy was planned for the whole pelvic field with superior margin of the sacral promontory. The volume and redundancy of rectosigmoid colon was assessed. Results: Patients in group B had straighter rectosigmoid colons than those in group A (no redundancy; group A vs. group B, 10% vs. 42%; p = 0.03). The volume of rectosigmoid colon in the radiation field was significantly larger in group A (56.7 vs. 49.1 mL; p = 0.009). In dose volume histogram analysis, the mean irradiated volume was lower in patients in group B (V45 27.2 vs. 18.2 mL; p = 0.004). In Pearson correlation coefficient analysis, the in-field volume of rectosigmoid colon was significantly correlated with the bladder volume (R = 0.86, p = 0.003). Conclusion: Use of a belly board and distended bladder protocol could contribute to exclusion of the proximal margin of anastomosis from the radiation field.

자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용 (Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma)

  • 정웅기;나병식;안성자
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.57-64
    • /
    • 1997
  • 목적 : 자궁경부암환자의 근치목적의 방사선치료 성적을 보고하기에 앞서 본원에서 사용하고 있는 자궁강내치료기기의 선량투여 방법의 정확성을 평가해보고 각 장기의 흡수선량을 대변할수 있는 예측력이 어느정도인지 알아보고자 연구를 시행하였다. 대상 및 방법 : 조준필름의 측면사진에서는 본원에서 현재 사용중인 방광(SBD)과 직장(SRD)의 기준흡수점의 흡수선량을 확인 하였다. 골반강 자기공명상의 측면사진에서 종양의 두 횡축과 종축의 직경을 곱하여 종양부피(TV)를 측정하였고, 기본으로 사음되고 있는 등선량곡선을 그린후 선량기준점 A 의 등선량 곡선내에 자궁경부 종양이 포함되는지 대상 환자별로 확인하였으며, 방광(MBD)과 직장(MRD)에서 보여주는 최대흡수선량점의 값을 측정하였고, 또한 선량기준점 A의 등선량 곡선내에 포함되는 방광(HBV)과 직장(HRV)의 면적을 계산해 보았다. 결 과 : 45례를 대상으로 분석하였다. 이중 53%(24/45) 에서만이 선량기준점 A의 등선량곡선내에 종양이 잘 포함되었다. 적절한 포함정도는 병기보다는 원발종양의 크기와 통계학적으로 유의한 관련성을 보여주었으며 종양의 측면지름의 크기가 3cm 이상인 종양은 불충분한 포함을 보여 주었다. 조준필름의 측면상의 방광과 직장의 기준흡수선량값은 자기공명사진상의 방광과 직장의 최대흡수값과 각각 유의한 관계를 보여주지 못했으나, 조준필름의 직장의 흡수선량값(SRD)은 HRV 와 유의한 관련성을 보여주었다. HBV 이나 HRV 은 오히려 자기공명사진상에서 측정한 종양의 크기(TV) 와 유의한 연관성을 보여 주었다. 결론 : 본원에서 사용하고 있는 선량계산 방법은 개별적인 종양의 크기를 고려해주지 못하였으며, 특히 방광의 흡수선량계산에 있어서 실제 흡수선량을 대변할수 있는 예측도가 낮아서 이에 대한 환자 개개인의 종양의 특성을 고려한 선량계산이 필요하리라 사료되는 바이다.

  • PDF

분할치료간(Interfraction) 내부 장기 움직임 오류 분석을 통한 전립선암의 전신정위적방사선치료(SBRT) 가능성 평가 (The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs)

  • 홍순기;손상준;문준기;김보겸;이제희
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.179-186
    • /
    • 2016
  • 목 적 : 분할치료간(Interfraction) 움직임에 의한 오류가 많은 직장과 방광 그리고 전립선의 변화를 MR영상을 기반으로 분석하여 보정치료계획(adaptive plan) 없이 SBRT 선량제한을 충족하는지 알아보고자 하였다. 대상 및 방법 : 본원에서 ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA)을 이용하여 전립선암에 총 선량이 70 Gy, 28회의 분할치료인 IMRT 치료를 시행한 환자 5명을 대상으로 하였다. 기존 치료방법을 가정하기 위해 ViewRay 모의치료계획과 동일한 날짜와 조건으로 촬영한 전산화단층촬영(Computed Tomography, 이하 CT)영상에 초기 치료계획을 생성하였고, 전산화치료계획은 Eclipse(Ver 10.0.42, Varian, USA)를 이용하였다. 분할치료간(Interfraction) 장기 변화를 분석하기 위해 치료계획용 CT영상에 각 5회 치료 자기공명영상(Magnetic Resonance Imaging, 이하 MRI)을 Registration 한 후, 초기 치료계획을 각 치료영상에 적용하여 선량체적곡선 변화와 각 장기의 절대용적 변화를 측정하였다. 처방선량은 5회에 걸쳐 PTV에 총 선량이 $V_{36.25}$ Gy $${\geq_-}$$ 95%가 되도록 하였고, 전립선 SBRT 선량제한의 충족 여부를 확인하기 위하여 직장과 방광의 $V_{100%}$, $V_{90%}$, $V_{80%}$ $V_{50%}$을 측정하였으며, CTV의 $V_{100%}$, $V_{95%}$, $V_{90%}$도 측정하였다. 결 과 : 총 5회의 CTV, 직장, 방광의 선량평균값은 5명 모두 SBRT 선량제한을 충족하였으나 각 치료 영상을 분석한 결과 1회 이상 선량제한을 초과하는 경우도 나타났다. 초기 치료계획과 분할치료의 MR영상을 비교하여 절대용적 변화를 측정한 결과 직장에서 최대 1.72배, 방광에서 최대 2.0배 차이를 보였다. 직장의 경우 초기 치료계획에서 5명의 측정값이 평균 $V_{100%}=0.32%$, $V_{90%}=3.33%$, $V_{80%}=7.71%$, $V_{50%}=23.55%$로 선량한도 이하로 계획 되었으나, 실제 분할치료 중 최대 3회까지 선량한도를 초과하기도 하였다. 방광의 경우도 초기 치료계획의 절대용적이 평균 117.9 cc 였으나 실제 치료 5회 평균용적은 79.2 cc 로 나타났다. CTV의 경우 방광과 직장의 용적 변화 등으로 인해 5 mm 여백을 포함한 PTV에 치료계획을 세웠음에도 불구하고 100% 처방선량 영역을 벗어나기도 하였다. 결 론 : 본 연구에서는 5회 치료 평균으로 분석한 결과 선량한도를 벗어난 경우는 없었으나, 각각의 분할치료에서는 직장과 방광의 오차가 비교적 큰 것을 확인 할 수 있었다. 그러므로 전립선암 SBRT를 시행하기 위해서는 선량 전달 정확성에 더욱 신중을 기해야 한다. 이를 위해서는 실시간 영상추적과 보정치료계획이 필수적이며 이것은 모든 방사선 치료가 궁극적으로 나아가야 할 방향으로 사료된다.

  • PDF

처방선량 및 치료기법별 치료성적 분석 결과에 기반한 자궁경부암 환자의 최적 방사선치료 스케줄 (Optimum Radiotherapy Schedule for Uterine Cervical Cancer based-on the Detailed Information of Dose Fractionation and Radiotherapy Technique)

  • 조재호;김현창;서창옥;이창걸;금기창;조남훈;이익재;심수정;서양권;성진실;김귀언
    • Radiation Oncology Journal
    • /
    • 제23권3호
    • /
    • pp.143-156
    • /
    • 2005
  • 목적: 고선량률 강내근접치료와 외부방사선의 병합치료는 자궁경부암의 표준치료법이지만, 최적의 병합 방식 및 선량 분할 스케줄은 아직 정해지지 않고 있다. 부분적으로는 이에 영향을 미치는 인자들의 다양성 및 기존의 문헌들의 방사선 선량에 관한 자세한 정보 부족을 그 이유로 들 수 있다. 이에 본 연구는 고선량률 강내근접치료에 대한 풍부한 경험을 바탕으로 단일기관에서 비교적 균일한 치료를 받은 많은 수의 환자 모집단을 대상으로 이들 다양한 인자들 및 방사선치료에 대한 자세한 분석을 통해서 최적의 방사선치료를 위한 지침을 얻고자 하였다. 대상 및 방법: 1990년부터 1996년까지 연세암센터에서 고선량률 강내근접치료 및 외부방사선치료로 자궁경부암에 대한 근치적 치료를 받은 743명의 환자들을 대상으로 하였으며, 중앙추적관찰 기간은 52개월이었다. FIGO 병기 분포는 IB 198명, IIA 77명, IIB 364명, IIIA 7명, IIIB 89명, IVA 8명이었다. 전골반방사선 선량은 $23.4\~59.4$ Gy (중앙값 45 Gy)의 분포를 보였으며, 진단 시 종양의 크기 및 외부방사선치료에 대한 종양의 반응에 따라서 그 시기를 조절하는 중앙차폐는 495예에서 시행되었으며, 그 시기는 $14.4\~43.2$ Gy (중앙값 36.0 Gy)로 비교적 광범위하고 다양한 분포를 보였다. 강내근접치료와 외부방사선치료의 분할 선량 차이를 극복하기 위해 생물학적 유효선량(Biologically Effective Dose, BED) 개념을 적용하였으며, 종양 및 정상 조직에 대한 $\alpha/\beta$비는 각각 10 및 3으로 하였다. 모든 개별 환자의 직장 전벽 및 방광 흡수선량을 분석하였고, 합병증 및 골반제어율과의 상관 관계를 규명하고자 하였다. 이외에도 방사선치료 스케줄에 영향을 미칠 수 있는 인자들인 총 치료기간, 강내근접치료의 분할 선량 크기, 주치의의 선호도에 따른 치료 스케줄 차이 등도 함께 고려하여 분석하였다. 결과: 전체 환자에서 RTOG Grade 1-4독성 발생률은 $33.1\%$였다. 전체 환자의 5년 골반제어율은 $83\%$로 분석되었다. 중앙차폐이전 외부방사선선량과 강내근접치료의 합산 BED값(=MD-BED $Gy_{\alpha/\beta}$$\alpha/\beta$=10인 경우 $62.0\~121.9\;Gy_{10}$ (중앙값: $93.0\;Gy_{10}$)의 분포를, ${\alpha/\beta}=3$인 경우 $93.6\~187.3\;Gy_3$ (중앙값=$137.6\;Gy_3$ )의 분포를 보였다. MD-BED $Gy_3$는 직장합병증 발생과의 관계는 통계적으로 유의하였고, 방광합병증과는 유의하지 않았다. 직장합병증과의 연관성은 MD-BED $Gy_3$보다 개별 환자의 직장전벽 총 선량 BED값인 R-BED $Gy_3$가 훨씬 더 높았다. 요도카테터 풍선의 후방지점이 대변하는 방광의 총 선량 BED값인 V-BED $Gy_3$도 방광합병증과 경향성 테스트에서 통계적 유의성을 보였다. 하지만, 어떠한 방사선선량도 골반제어율과 의미 있는 상관관계를 보이지 않았다. 본 기관에서 주치의의 선호도에 따라 강내근접치료가 외부방사선치료의 중간에 시행되는 형태인 샌드위치기법과 외부방사선치료 후반부에 시행되는 순차적 기법으로 구분하였을 때, 두 방식간 치료성적 및 합병증의 차이는 없었다. 총 치료기간에 대한 분석에서는 치료기간이 길어질수록 재발 위험이 커지는 경향을 보였으나, 나이 및 병기, 종양의 크기, MD-BED $Gy_{10}$ 등의 예후 인자를 보정한 다변량분석에서는 치료기간이 100일 이상인 경우에만 통계적으로 유의하게 증가하였다. 강내근접치료 분할선량 크기인 3 Gy와 5 Gy 사이에 골반제어율 및 합병증의 차이는 없었다. 결론: 자궁경부암의 최적방사선치료 스케줄에 대한 지침을 세우기 어렵게 만드는 가장 중요한 이유는 강내근접치료가 갖는 선량분포 특성에서 기인하는 방사선선량-골반제어율 상관 관계의 부재 및 개별 종양의 방사선에 대한 반응 속도가 환자마다 크게 다를 수 있다는 점이다. 따라서 전체적인 원칙과 함께 개인화된 맞춤치료가 필요하다. 치료 지침에 영향을 미칠 수 있는 요소들의 복합적인 고려도 중요하다고 할 수 있겠다. 합병증 발생이 우려되는 경우 생물학적 유효선량을 낮추기 위해 적절한 조기 중앙차폐 및 강내근접치료의 분할선량 크기 감소를 고려해볼 수 있다.

아주대학교병원에서의 전립선암에 대한 래피드아크 치료 (First Clinical Experience about RapidArc Treatment with Prostate Cancer in Ajou University Hospital)

  • 박혜진;김미화;전미선;오영택;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.183-191
    • /
    • 2010
  • 본 논문에서는 세기조절방사선치료와 이중회전(double arcs)을 통한 래피드아크 치료용 치료계획을 수행하였고, 각각의 선량분포와 DVH의 특성을 비교, 평가하였다. 또한 정도관리를 통해 래피드아크 치료에 대한 신뢰도 및 정확도를 평가하고 이러한 과정들을 통해 환자에 대한 적절한 치료방법을 제시하고자 하였다. 두 치료기술에 대한 치료계획 시 임상표적 용적(Clinical Target Volume, CTV)과 치료표적용적(Planning Target Volume, PTV)과 직장에 동일한 최적화 조건을 적용하였고, 그 외 정상조직에 대하여 최적화 조건 없이 가장 단순화한 조건에서 최적화의 능력과 결과 차이를 비교하였다. 래피드아크는 세기조절방사선치료와 비교하였을 때 동일한 선량제한치 적용 후 결과는 종양에 전달되는 선량은 증가하고 손상위험장기에 대해서는 더 보호하는 능력을 보여주고 있다. 따라서 세기조절방사선치료와 비교하였을 때 치료부피와 주변 장기의 부작용에 대하여 주변장기에 대한 조사선량은 줄이면서 종양에는 더 많은 선량이 조사되었다. 본 연구를 통하여 래피드아크 치료는 기존에 시행하고 있는 세기조절방사선치료 기법보다 더욱 최적의 선량 분포를 구현하고, 치료시간에 있어 보다 효율적이라는 것을 알 수 있었다. 그리고 정밀한 치료 기법인 만큼 정확한 래피드아크 치료를 시행하기 위해서는 치료 계획과 실제로 시행되는 치료가 일치하는지 확인하는 정도관리 과정이 반드시 필요하다는 것을 알 수 있었다.

체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가 (The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT)

  • 김연래;정진범;이정우;신영주;강동진;정재용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

병기 I, II 자궁 경부암에서 방사선치료 후 생존율 및 합병증 분석 (Survival and Complication Rate of Radiation Therapy in Stage I and II Carcinoma of Uterine Cervix)

  • 마선영;조흥래;손승창
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.349-357
    • /
    • 1995
  • 목적 : 수술을 시행 받지 않은 IB, IIA, IIB 자궁경부암 환자에서 외부 방사선 조사 및 강내조사 방법에 따른 생존율과 방광 및 직장 합병증 발생률을 분석하여 보고자 하였다. 방법 : 1984년 11월 부터 1993년 12월 까지 인제대학교 부산백병원 치료방사선과에서 근치적 방사선치료 또는 화학요법을 병행한 자궁경부암 병기 IB, IIA, IIB 환자 127명 중 추적 가능하였던 환자 107명을 대상으로 생존율을 후향적 분석하였고, 합병증은 91명에서 추적 가능하였다. 방사선 단독으로 치료 받은 환자가 86명, 보조적 화학요법을 받은 환자는 21명이었다. 대상 환자들의 추적 조사 기간은 3개월에서 118개월이었고 (중앙값, 47개월), 환자의 연령은 31세에서 76세까지 (중앙값, 56세) 분포를 보였다. FIGO 병기 IB기가 26명, IIA기가 40명, IIB기가 41명 이었다. 강내 방사선 조사는 저선량률 강내조사를 받은 군(80명)과 고선량률 강내조사를 받은 군(21명)으로 나누어 분석하였다. 저선량률 강내조사는 1회 시행받은 환자군(63명)과 2회로 나누어 시행받은 환자군(17명)을 비교하여 보았고, 저선량률 강내조사를 받은 환자 중에서 전골반 외부 조사선량에 따라 4500cGy 이하인 환자군(18명)과 4501cGy 이상인 환자군(62명)으로 나누어 분석하였다. 외부 조사선량이 5000cGy 이상인 환자 중에서 중심선 차폐(midline block)를 한 군(36명)과 하지 않은 군(31명)을 나누어 분석하였다. 결과 : 전체 환자의 5년생존율은 $69{\%}$였고, 병기별 5년생존율은 IB $92{\%}$, IIA $75{\%}$, IIB $53{\%}$로 나왔다. 직장 합병증은 Grade 1이 20명($22{\%}$), Grade 2가 22명($24{\%}$) 이었고, 방광 합병증은 Grade 1이 22명($24{\%}$), Grade 2가 17명($19{\%}$) 이었으며 수술을 요할 정도의 심각한 합병증은 없었다. 방광 및 직장 합병증이 나타났던 군에서 합병증이 없었던 군보다 방광 및 직장에 조사된 최대 방사선량(maximum dose)의 평균치가 높았던 것으로 나타났다 (최대 방광 조사선량 평균 : 7608cGy v 6960cGy (p<0.01), 최대 직장 조사선량 평균 : 7041cGy v 6269cGy (p<0.01)). 외부 조사선량이 4500cGy 이하인 군과 4501cGy 이상인 군에서 생존율과 방광 합병증 발생율은 통계적 차이가 없었으나 Grade 2 직장 합병증 발생율은 각각 $6.3{\%},\;25.5{\%}$ (p<0.05)로 4500cGy 이하인 군에서 낮은 것으로 나타났다. 고선량률 강내조사를 받은 군과 저선량률 강내 조사를 받은 군 사이에 생존율은 병기별 분석에서 유의한 차이가 없었으며, 합병증 발생률은 고선량률 강내조사 군에서 더 높게 나타났지만 Point A와 직장에 조사된 방사선량이 저선량률 강내조사 군에 비해 높아 고선량률 강내치료 자체가 합병증 발생률을 높인 인자로 볼 수는 없었다 (p<0.01). 저선량률 강내조사의 횟수에 따른 생존율이나 합병증 발생률의 차이는 없었다. 외부조사시 중심선 차폐 여부에 따른 생존율과 직장 합병증 발생률의 유의한 차이는 없었으나 방광 합병증 발생률은 중심선 차폐를 시행한 군에서 더 높았다 (p<0.05). 결론 : 병기 IB, IIA, IIB 자궁경부암에서 방사선 치료방법에 따른 생존율은 통계적으로 유의한 차이는 없었으며, 직장 합병증은 외부 조사선량이 4500cGy이하인 군에서 4501cGy 이상인 군에서보다 낮은 것으로 나타났고, 최대 방광 선량과 최대 직장 선량이 합병증 발생률과 유의한 상관관계를 보여, 향후 전골반 외부 조사선량이 4500cGy를 넘지 않도록 주의하여야 되겠고, 강내 치료 계획시 직장 및 방광 선량을 가능한 낮추도록 치료 선량을 결정해야 할 것이다.

  • PDF

Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

  • Hojeong Lee;Dong Woon Kim;Ji Hyeon Joo;Yongkan Ki;Wontaek Kim;Dahl Park;Jiho Nam;Dong Hyeon Kim;Hosang Jeon
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.101-107
    • /
    • 2022
  • Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the need to hold back urine during treatment, patients frequently complain of discomfort, and treatment is frequently suspended when patients urinate during treatment and urine penetrates the treatment device, causing malfunction. Therefore, the effect of minimizing treatment time when partial-arc volumetric modulated arc therapy (VMAT) was used instead of full-arc was assessed in this study. Methods: A total of 70 plans were created in 10 patients using 7 different arc sizes, and the treatment time for each plan was calculated. Results: Reduced arc size by half resulted in a 54.4% decrease in mean treatment duration, with a proportional tendency observed. Furthermore, the effect of VMAT arc size reduction on target dose homogeneity was significantly limited, and the effect on surrounding organs at risk (OAR) was negligible. It should be noted, however, that when the arc size decreases by >40%, the dose increases in the area without OAR around the target. Conclusions: The results of this study demonstrated that partial-arc VMAT for enhancing treatment convenience and efficacy of prostate cancer patients undergoing BFP can achieve a considerable reduction in treatment time while preserving treatment quality, and it is expected to be useful for partial-arc VMAT plan design and implementation in practice.

인삼 사포닌이 하부요로와 음경해면체 평활근의 이완작용에 미치는 효과 (The Effects of Ginseng Saponin on Relaxation of Smooth Muscle in the Lower Urinary Tract and the Corpus Cavernosum)

  • 정희창;오태희
    • Journal of Yeungnam Medical Science
    • /
    • 제23권1호
    • /
    • pp.52-61
    • /
    • 2006
  • 이상의 결과를 종합하면, 인삼 총사포닌은 본 실험의 조건에서 배뇨개선 효과가 있으며 이에 관여하는 총사포닌의 주 효능은 근위부요도를 이완시킴으로써 이루어지는 것으로 생각된다. 그리고 인삼 총사포닌은 혈류역동학적으로 안전하게 음경해면체 평활근을 이완시켜 음경발기를 유발시키는 것으로 생각된다.

  • PDF

자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교 (Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer)

  • 조정근;한태종
    • Journal of Radiation Protection and Research
    • /
    • 제32권3호
    • /
    • pp.105-110
    • /
    • 2007
  • 최근 CT, MRI, PET등 영상진단기술 및 방사선치료계획 소프트웨어 등이 획기적으로 발전하였음에도 불구하고 자궁경부암의 강내조사는 아직까지 A점 등 ICRU 38에 근거한 치료계획을 보편적으로 사용하고 있다. CT를 이용한 3차원 강내조사 계획은 종양 및 정상조직의 선량-용적 히스토그람(DVH)에 대한 정보를 제공한다. 본 연구에서는 CT를 이용하여 표적용적(CTV)에 목표선량을 조사하는 치료계획(CTV 치료계획)과 ICRU38에 근거한 치료계획(ICRU 치료계획)을 시행하고, 각각에 대한 DVH를 분석하여 두 치료계획간의 종양선량, 직장선량, 방광선량 등을 비교하였다. Ir-192 고선량율강내치료(HDR)를 받은 11명의 환자를 대상으로 하였다. 강내조사 치료계획은 외부방사선치료를 일일선량 180cGy씩 4문조사(Box technique)로 약 40Gy 시행한 후 수립되었으며 모든 환자에서 CT 모의치료기를 이용한 CT가 시행되었고 치료계획은 PLATO(Nucletron) v.14.2를 이용하였다. CT 영상에 CTV, 직장, 방광 등을 도시한 후 CTV에 100%의 선량을 조사하는 치료계획 및 ICRU 38에 근거하여 A점에 100%를 조사하는 치료계획을 수립하였다. 11명 환자의 CTV 용적(평균${\pm}$표준편차)은 $21.8{\pm}26.6cm^3$, 직장 용적은 $60.9{\pm}25.0cm^3$, 방광용적은 $111.6{\pm}40.1cm^3$이었으며, 100%의 선량이 포함하는 용적은 ICRU 치료계획에서는 $126.7{\pm}18.9cm^3$, CTV 치료계획에서는 $98.2{\pm}74.5cm^3$이었다. (p=0.0001). ICRU 치료계획 시 잔류종양의 크기가 4cm 이상인 1례에서는 CTV 용적 $22.0cm^3$가 100% 등선량곡선에 포함되지 않았으며 잔류종양의 크기가 4cm 미만인 나머지 10례에서는 종양용적 이외의 정상조직 $62.2{\pm}4.8cm^3$이 불필요하게 100% 이상의 선량이 조사되었다. ICRU 38의 권고에 따른 방광선량은 ICRU 치료계획 및 CTV 치료계획에서 각각 $90.1{\pm}21.3%,\;68.7{\pm}26.6%$이었고(p=0.001), 직장선량은 $86.4{\pm}18.3%,\;76.9{\pm}15.6%$이었다(p=0.08). 방광 및 직장선량의 최대 점선량 또한 ICRU 치료계획과 CTV계획에서 각각 $137.2{\pm}50.1%$ vs $107.6{\pm}47.9%$, (p=0.008), $101.1{\pm}41.8%$ vs $86.9{\pm}30.8%$ (p=0.045) 로서 CTV 치료계획에서 정상조직에 조사되는 선량이 더 적게 나타났다. 그러나 잔류종양이 4cm 이상인 환자에서는 CTV 치료계획에서 정상조직 선량이 권고 선량보다 현저히 높게 나타났다. 방광 및 직장의 용적선량에서는 투여선량의 80% 이상을 받는 직장용적선량(V80rec)은 ICRU 치료계획 및 CTV 치료계획에서 각각 $1.8{\pm}2.4cm^3,\;0.7{\pm}1.0cm^3$(p=0.02), 방광용적선량(V80bla)은 $12.2{\pm}8.9cm^3,\;3.5{\pm}4.1cm^3$로서 역시 CTV 치료계획에서 적게 조사되었다(p=0.005). 기존의 ICRU 치료계획은 잔류종양의 크기가 작은 경우 불필요하게 정상조직에 많은 선량이 투여되기 때문에 CT를 이용한 CTV 치료계획을 적용하여 정상조직에 대한 피폭을 현저히 낮추고 잔류종양에 목표한 선량을 조사할 수 있다. 다만 잔류종양의 크기가 큰 경우에는 정상조직에 대한 조사선량을 줄이기 위한 효과적 치료계획에 대한 연구가 필요할 것으로 판단된다.