• 제목/요약/키워드: Bladder dose

검색결과 160건 처리시간 0.025초

Feline Interstitial Cystitis Enhances Mucosa-Dependent Contractile Responses to Serotonin

  • Ikeda, Youko;Wolf-Johnston, Amanda;Roppolo, James R.;Buffington, Charles A.T.;Birder, Lori
    • International Neurourology Journal
    • /
    • 제22권4호
    • /
    • pp.246-251
    • /
    • 2018
  • Purpose: To determine whether responses to serotonin are altered in bladder strips from cats diagnosed with a naturally occurring form of bladder pain syndrome/interstitial cystitis termed feline interstitial cystitis (FIC). Methods: Full thickness bladder strips were isolated from aged matched healthy control cats and cats with clinically verified FIC. Bladder strips were mounted in an organ bath and connected to a tension transducer to record contractile activity. A serotonin dose response ($0.01-10{\mu}M$) was determined for each strip with the mucosa intact or denuded. Results: Bladder strips from control and FIC cats contracted in response to serotonin in a dose-dependent manner. The normalized force of serotonin-evoked contractions was significantly greater in bladder strips from cats with FIC (n=7) than from control cats (n=4). Removal of the mucosa significantly decreased serotonin-mediated responses in both control and FIC bladder preparations. Furthermore, the contractions in response to serotonin were abolished by $1{\mu}M$ atropine in both control and FIC bladder strips. Conclusions: The effect of serotonin on contractile force, but not sensitivity, was potentiated in bladder strips from cats with FIC, and was dependent upon the presence of the mucosa in control and FIC groups. As atropine inhibited these effects of serotonin, we hypothesize that, serotonin enhances acetylcholine release from the mucosa of FIC cat bladder strips, which could account for the increased force generated. In summary, FIC augments the responsiveness of bladder to serotonin, which may contribute to the symptoms associated with this chronic condition.

자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가 (Dose Distribution of Rectum and Bladder in Intracavitary Irradiation)

  • 추성실;오원용;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

복부판과 소장변위도구를 사용하는 직장암의 방사선치료 시 비만도가 소장의 조사용적에 미치는 영향 (The Effect of Obesity Levels on Irradiated Small Bowel volume in Belly Board with Small Bowel Displacement Device for Rectal Cancer Radiotherapy)

  • 김세영;김주호;박효국;조정희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.39-47
    • /
    • 2013
  • 본 연구의 목적은 방사선 조사 용적 내 포함되는 소장의 용적 감소를 위해 복부판(Belly board, 벨리보드)과 소장변위도구(Small Bowel Displacement Device, SBDD)를 사용한 직장암 환자에서 방사선 치료 영역 내 포함되는 소장의 용적과 비만도 와의 상관성을 보고, 비만지표의 적용을 통해 SBDD의 사용지표를 삼고자 한다. 실험은 2012년 1월부터 4월까지 수술 전 혹은 수술 후 벨리보드와 SBDD를 사용해 골반부위에 방사선치료를 받은 29명의 직장암 환자를 대상으로 분석하였다. 방사선 치료는 3문 조사로 시행하였으며 1.8 Gy의 분할선량으로 중심점에 45 Gy를 조사한 계획만을 분석하였다. 환자의 키, 몸무게, 체질량지수(body mass index, BMI), 허리 엉덩이 둘레비(waist hip ratio, WHR)를 측정하여 비만도를 조사하였다. 조사되는 선량의 90%이상 들어가는 소장의 용적(high dose volume of small bowel, $HDV_{sb}$)과 33%이상 들어가는 소장의 용적(low dose volume of small bowel, $LDV_{sb}$)을 방광의 총 용적(total volume of bladder, $TV_{bladder}$) 및 비만도에 따라 비교하여 그 상관관계를 통계학적으로 분석하였다. 분석결과 수술여부 및 성별 WHR은 $HDV_{sb}$, $LDV_{sb}$에 크게 미치는 영향이 없었고 $HDV_{sb}$, $LDV_{sb}$와 BMI(p=0.031/0.083), $TV_{bladder}$ (p<0.05)는 통계적으로 유의하였다. BMI가 $HDV_{sb}$와는 유의 하지만 $LDV_{sb}$와는 크게 유의하지 않았다. (p=0.031, p>0.05) BMI는 $HDV_{sb}$와 음의 상관관계(${\beta}$=-0.402)가 있었으며 $TV_{bladder}$$HDV_{sb}$, $LDV_{sb}$와 음의 상관관계(${\beta}$=-0.497/-0.522)가 있었다. 특히 BMI 23 미만인 경우(BMI Group2)보다 그 이상인 경우 $HDV_{sb}$에 영향을 미치며 음의 상관성(${\beta}$=-0.525)이 있었다.($LDV_{sb}$, $HDV_{sb}$와 유의확률 각각 p=0.059, p=0.027) BMI가 23 이상인 집단(BMI Group1)에서는 $TV_{bladder}$$HDV_{sb}$, $LDV_{sb}$가 통계학적으로 유의하였고(p<0.04) 음의 상관성을 보였다. 비만지표인 BMI가 23 이상인 과체중 및 비만군의 직장암 방사선 치료 시 벨리보드와 SBDD를 동시에 사용하는 경우 조사용적 내 포함되는 소장의 용적을 감소시키는데 더 효과적이었다. 그러므로 벨리보드를 사용하는 직장암의 방사선 치료 시 BMI 23 이상인 한국인 환자에게는 소장변위도구를 동시에 사용 할 것을 권장한다.

A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy

  • Mattes, Malcolm D.;Lee, Jennifer C.;Elnaiem, Sara;Guirguis, Adel;Ikoro, N.C.;Ashamalla, Hani
    • Radiation Oncology Journal
    • /
    • 제32권1호
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The goal of this study is to determine whether the magnitude of overlap between planning target volume (PTV) and rectum ($Rectum_{overlap}$) or PTV and bladder ($Bladder_{overlap}$) in prostate cancer volumetric-modulated arc therapy (VMAT) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose-volume constraints are unlikely to be met. Materials and Methods: Fifty-seven patients with prostate cancer underwent VMAT planning using identical optimization conditions and normalization. The PTV (for the 50.4 Gy primary plan and 30.6 Gy boost plan) included 5 to 10 mm margins around the prostate and seminal vesicles. Pearson correlations, linear regression analyses, and receiver operating characteristic (ROC) curves were used to correlate the percentage overlap with dose-volume parameters. Results: The percentage $Rectum_{overlap}$ and $Bladder_{overlap}$ correlated with sparing of that organ but minimally impacted other dose-volume parameters, predicted the primary plan rectum $V_{45}$ and bladder $V_{50}$ with $R^2$ = 0.78 and $R^2$ = 0.83, respectively, and predicted the boost plan rectum $V_{30}$ and bladder $V_{30}$ with $R^2$ = 0.53 and $R^2$ = 0.81, respectively. The optimal cutoff value of boost $Rectum_{overlap}$ to predict rectum $V_{75}$ >15% was 3.5% (sensitivity 100%, specificity 94%, p < 0.01), and the optimal cutoff value of boost $Bladder_{overlap}$ to predict bladder $V_{80}$ >10% was 5.0% (sensitivity 83%, specificity 100%, p < 0.01). Conclusion: The degree of overlap between PTV and bladder or rectum can be used to accurately guide physicians on the use of interventions to limit the extent of the overlap region prior to optimization.

골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석 (The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation)

  • 이경자
    • Radiation Oncology Journal
    • /
    • 제26권4호
    • /
    • pp.271-279
    • /
    • 2008
  • 목 적: 골반강에 방사선치료 중 벨리보드를 사용함으로써 방사선에 조사되는 소장과 방광의 체적 변화를 측정하여 벨리보드의 효과를 알아보기 위한 연구이다. 대상 및 방법: 골반강 종양으로 골반강에 4문 대향 방사선조사를 받은 22명(자궁경부암; 14명, 직장암; 6명, 자궁 내막암; 2명)의 환자를 대상으로 하였으며 22명 중 4명은 근치적 목적으로 방사선치료만 시행하였으며, 18명은 수술 후 보강성 목적으로 방사선치료를 시행하였다. 모든 환자는 엎드린 상태에서 벨리보드를 사용한 경우와 사용하지 않은 경우의 2세트의 골반강 전산화 단층촬영을 시행하였다. 전산화 단층촬영으로 얻은 영상은 치료계획용 컴퓨터 시스템으로 이송하여 소장과 방광 외면의 윤곽과 4문 조사에서 표적물의 윤곽을 그렸다. 전산화 단층촬영의 영상에서 각각의 환자에서 벨리보드를 사용한 상태와 사용하지 않은 상태에서 소장과 방광의 방사선조사야에 포함되는 전체 체적과, 선량체적히스토그램(dose-volume histogram)을 이용하여 방사선량에 따른 방광 및 소장의 체적을 비교 분석하였다. 결 과: 모든 환자에서 벨리보드를 사용한 경우가 사용하지 않은 경우에 비해 방사선조사에 포함되는 소장의 체적이 감소되었으며($1{\sim}79%$), 평균 35% 감소되었다(p<0.001). 또한 처방선량의 $10{\sim}100%$까지 모든 선량에서 벨리보드를 사용한 경우 소장의 체적이 통계학적으로 유의하게 감소되었다 (p<0.001). 방사선에 조사되는 방광의 체적의 변화는 벨리보드를 사용한 경우가 사용하지 않은 경우에 비해 최대 8 cc 미만으로 변화가 없었다(p=0.762). 그러나 처방선량의 90%를 받는 방광의 체적이 벨리보드를 사용한 경우 15명(68%)은 100%, 7명(32%)은 $90{\sim}99%$이었으며 벨리보드를 사용하지 않은 경우 10명(45%)은 100%, 7명(32%)은 $90{\sim}99%$, 5명(23%)은 $80{\sim}89%$로 벨리보드를 사용한 경우 고선량을 받는 방광의 범위가 증가되는 경향을 보였다. 결 론: 자궁경부암, 자궁내막암과 직장암 환자에 근치적 목적 혹은 수술 후 보강성 목적으로 골반강에 방사선치료 중 벨리보드를 사용함으로써 모든 환자에서 방사선조사를 받는 소장의 체적을 감소시킬 수 있음을 확인할 수 있었다. 그러나 벨리보드가 방광을 방사선조사야 내로 이동시킴에 따라 처방선량의 90%를 받는 방광의 체적이 증가할 수 있기 때문에 고선량의 방사선을 조사할 경우 방광의 손상을 고려하여 벨리보드의 사용을 신중히 선택해야 할 것으로 생각한다.

전립선암의 세기조절 방사선 치료시 밀도보정의 효과 (The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy)

  • 한영이;박원;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제15권3호
    • /
    • pp.149-155
    • /
    • 2004
  • 목적: 전립선암의 세기조절 방사선 치료 시, 조직의 밀도보정 여부가 선량분포에 끼치는 영향을 연구한다. 재료 및 방법: 5명의 전립선 암 환자에 대하여 6 MV와 10 MV의 광자선에 대하여 각각 치료계획을 수립하였다. 각각 의 계획에서 7개의 조사선이 설정되었고, 선량계산 시에는 체조직의 밀도의 불균일성을 무시하였다. 선량 처방점인 회전중심점에서의 흡수선량과 계획표적용적(PTV)의 최대선량, 최소선량, 평균선량과 처방점선량의 95% 이상의 받는 부피(V>$_{p95%}$) 등을 측정하였다. 직장과 방광 내에서의 최대선량, 최소선량, 최방선량의 50%, 75%, 90% 이상을 받는 부피를 측정하였다. 동일한 조건에서 조직의 밀도 불균일성을 포함하여 선량분포를 재계산하고, 측정한 모든 물리량을 재 측정하였다. 결과: 밀도보정을 함으로써, 처방점에서의 흡수 선량은 6 MV에서 평균 4.9% 10 MV에서는 평균 4% 감소하였다. V>$_{p95%}$는 6 MV와 10 MV에서 각각 0.8%와 0.9% 감소하였다. PTV의 평균 흡수 선량은 6 MV와 10 MV에서 각각 4.2% 와 3.4% 감소하였다. 직장과 방광에서의 흡수선량은 약 l~2%의 차이를 보였다 결론: 전립선암의 세기변조 방사선치료시에 밀도보정을 무시하는 것은 표적에는 고려할 만한 선량의 차이를 유발하며, 주위의 위험장기에 미치는 영향은 미미하다.

  • PDF

고선량 강내 조사법을 이용한 자궁 경부암의 방사선 치료 계획에 대한 임상적 고찰 (Clinical Evaluation of Dose Distribution in High Dose Rate Intracavitary Irradiation in the Treatment of Cervical Cancer)

  • 신세원;김명세
    • Journal of Yeungnam Medical Science
    • /
    • 제6권1호
    • /
    • pp.87-98
    • /
    • 1989
  • 영남대학교 의과대학 부속병원에서 고선량율 강내 치료를 받은 53명에 대한 결과는 다음과 같다. 1. 환자 분포는 40대에서 60대가 42명으로 전체의 79.2%를 차지하였다. 2. 임상적 병기는 Stage-II가 31명으로 58.5%를 차지하였다. 3. 점-A의 선량은 3,501-4,000cGy가 41명으로 전체의 77.4%를 차지하였으며 왼쪽이 많은 경우가 81.2%이었다. 4. 점-B의 선량은 1001-1250cGy가 44명으로 전체의 83%를 차지하였으며 양측 선량의 차이는 400cGy이내였다. 5. 점-A선량에 대한 방광의 선량 비율은 50%미만이 33명이었다. 6. 점-A선량에 대한 하부직장의 선량 비율은 60% 미만이 48명이었다. 7. 점-A선량에 따른 상부 직장의 선량 비율은 60% 미만이 38명이었다. 8. 자궁의 위치는 좌측 편위가 36명으로 전체의 58.9%를 차지하였으며 자궁강의 길이는 4.4cm~5.3cm가 30명으로 30명으로 56.6%를 차지하였다. 9. 자궁의 전후 위치는 중위 및 후굴이 40명으로 75.5%를 차지하였다. 10. 자궁의 위치에 따른 직장 선량의 분포는 후굴 및 중위에서 전굴에 비해서 다소 증가하는 양상을 보였다.

  • PDF

전립선암 영상유도방사선치료 시 pCT와 CBCT에 따른 치료계획별 체적선량의 변화 (Changes in Volume Dose by Treatment Plan According to pCT and CBCT in Image-guided Radiation Therapy for Prostate Cancer)

  • 원영진;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.209-214
    • /
    • 2018
  • The results of CBCT was obtained using image guided radiation therapy for radiation therapy in 5 prostate cancer patients. Using these results, we compared and evaluated the dose changes according to the treatment plan depending on the volume and position of bladder, rectum, and prostate. The 28 images of CBCT were acquired using On-Board Imaging device before radiotherapy. After the outline of bladder, rectum, and PTV, pCT images and CBCT images for radiotherapy were treated respectively. The volume of the bladder was increased by 105.6% and decreased by 45.2%. The volume of the rectum was increased by 30.5% and decreased by 20.3%. Prostate volume was increased by 6.3% and decreased by 12.3%. The mean dose of the rectum was higher in the CBCT than in the pCT, and V40 (equivalent to 40 Gy) of the bladder showed a reduction in all treatment regimens in the CBCT than in the pCT. Conformity treatment and homogeneity index of PTV showed better results in all treatment regimens using pCT than CBCT. It was found that the dose distribution of the pelvic internal organs varied greatly according to the patient 's condition and pretreatment.

자궁경부암 근접방사선치료 시 2차원, 3차원 치료계획 비교평가 (Comparison of 2D and 3D Brachytherapy Planning for Cervical Cancer)

  • 김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.303-309
    • /
    • 2017
  • 본 연구에서는 자궁경부암의 치료를 위한 전산화단층촬영(computer tomography)영상을 이용한 3차원 근접치료계획의 유용성을 알고자 하였다. 10명의 자궁경부암 환자에서 2차원 근접치료계획을 시행하였고, 동일 자세로 전산화단층촬영을 시행하였다. 3차원 근접치료계획 프로그램(ECLIPSE treatment planning system v6.5, Varian Medical System, USA)를 이용하였으며, 고위험임상표적체적(High risk CTV, HR CTV)에 5 Gy를 처방하였다. 3차원 근접치료계획의 제한은 적어도 고위험임상표적체적의 90%에 처방선량인 5 Gy가 조사되도록, 방광의 $2cm^3$에 7.5 Gy 미만으로 들어가도록 그리고 직장의 $2cm^3$에 5 Gy 미만이 들어가도록 하였다. 계획의 평가는 선량체적표(dose-volume histograms; DVHs)를 이용하여 육안적종양체적(Gross tumor volume for brachytherapy; $GTV_B$), 고위험임상표적체적, 직장과 방광에 조사되는 선량을 구하였다. 크기가 큰 종양이나 자궁의 위치이상이 있는 환자에서 Point A에 처방한 2차원 근접치료계획을 하였을 경우에는 고위험임상표적체적이 충분히 포함되지 않았다. 그러나 3차원 근접치료계획은 이러한 환자들에서 직장이나 방광의 선량을 증가시키지 않고 고위험임상표적체적을 잘 포함할 수 있었다. 2차원 근접치료계획에서 높은 선량부터 $2cm^3$에 들어가는 직장선량은 10명 중 1명에서, $2cm^3$에 들어가는 방광선량은 6명에서 5 Gy를 넘었으므로 ICRU (International Commission on Radiation Units) 방광선량이 직장선량에 비해 과소평가됨을 확인할 수 있었다. 자궁경부암 환자에서 전산화단층촬영 이용한 3차원 근접치료계획은 종양과 위험장기에 대한 선량평가가 가능하므로, 직장과 방광의 부작용을 증가시키지 않으면서 크기가 큰 종양이나 자궁의 위치이상이 있는 환자에서 위치 설정의 오류를 줄일 수 있을 것으로 생각된다.