A Comparison Study of Input ESD Protection schemes Utilizing Thyristor and Diode Devices (싸이리스터와 다이오드 소자를 이용하는 입력 ESD 보호방식의 비교 연구)

  • Choi, Jin-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.75-87
    • /
    • 2010
  • For two input-protection schemes suitable for RF ICs utilizing the thyristor and diode protection devices, which can be fabricated in standard CMOS processes, we attempt an in-depth comparison on HBM ESD robustness in terms of lattice heating inside protection devices and peak voltages developed across gate oxides in input buffers, based on DC, mixed-mode transient, and AC analyses utilizing a 2-dimensional device simulator. For this purpose, we construct an equivalent circuit for an input HBM test environment of a CMOS chip equipped with the input ESD protection circuits, which allows mixed-mode transient simulations for various HBM test modes. By executing mixed-mode simulations including up to six active protection devices in a circuit, we attempt a detailed analysis on the problems, which can occur in real tests. In the procedure, we suggest to a recipe to ease the bipolar trigger in the protection devices and figure out that oxide failure in internal circuits is determined by the junction breakdown voltage of the NMOS structure residing in the protection devices. We explain the characteristic differences of two protection schemes as an input ESD protection circuit for RF ICs, and suggest valuable guidelines relating design of the protection devices and circuits.

Radiation Damage of Semiconductor Device by X-ray (엑스선에 의한 반도체 소자의 방사선 손상)

  • Kim, D.S.;Hong, H.S.;Park, H.M.;Kim, J.H.;Joo, K.S.
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.110-117
    • /
    • 2015
  • Recently, Due to the increased industry using radiation inspection equipment in the semiconductor, this demand of technology research is increasing. Although semiconductor inspection equipment is using low energy X-ray from 40 keV to 120 keV, Studies of radiation damage about the low energy X-ray are lacking circumstance in our country. Therefore, It is study that BJT (bipolar junction transistor) of one type of semiconductor elements are received radiation damage by low energy X-ray. BJT were used to the NXP semiconductor company's BC817-25 (NPN type), and Used the X-ray generator for the irradiation. Radiation damage of BJT was evaluated that confirm to analyse change of collector-emitter voltage of before and after X-ray irradiation when current gain fixed to 10. X-ray generator of tube voltage was setting 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp and irradiation time was setting 180s, 360s, 540s into 180s intervals. As the result, We confirmed radiation damage in BJT by low energy X-ray under 120 keV energy, and Especially the biggest radiation damage was appeared at the 80 kVp. It is expected that ELDRS (enhanced low dose rate sensitivity) phenomenon occurs on the basis of 80 kVp. This studies expect to contribute effective dose administration of semiconductor inspection equipment using low energy X-ray, Also Research and Development of X-ray filter.

Radiofrequency thermal Shrinkage for Elongated Anterior Cruciate Ligament after Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술 이후 이완된 전방십자인대에 시행한 고주파 에너지 열 수축)

  • Kim, Yeung-Jin;Chun, Churl-Hong;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Joon;Kim, Young-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: To evaluate the clinical results of the patients who underwent radiofrequency thermal shrinkage (RFTS) for treatment of anterior cruciate ligament (ACL) laxity after ACL reconstruction. Material and Methods: From October 1999 to March 2006, we performed 133 cases of ACL reconstruction. Among them we experienced 16 patients who had the laxity of reconstructed ACL in second look arthroscopy. Mean follow-up was 20.4 months. Mean age was 33.5 years. 12 cases were male and 4 cases were female. The elongated ACL were treated by bipolar radiofrequency energy with an output of grade II. Subjective and objective parameters were utilized in analyses, such as: the mean range of motion, Lysholm knee score, Tegner activity score, Lachman test, IKDC score. Wilcoxon signed-rank test was used to perform the data analysis. P<0.05 was considered to be statistically significant. Results: Postoperative mean Lysholm knee score (preop: $82.2{\pm}5.2(77{\sim}85))$ (P=0.04), postop: $85.2{\pm}4.8$(82-90)) and anterior displacement by the Telos stress test (preop: $5.4{\pm}4.6(3{\sim}10)mm$, postop: $2.1{\pm}1.9(0{\sim}4)mm)$ (P=0.02), Lachman's test, and IKDC scores (P=0.04) demonstrated significant differences statistically compared to the preoperative. There were no statistical differences in mean range of motion, Tegner activity scale. Conclusions: Arthroscopic shrinkage for the ACL laxity after ACL reconstruction with radiofrequency device showed good clinical results and was applicable operative technique.