• Title/Summary/Keyword: Biostimulation effect

Search Result 14, Processing Time 0.02 seconds

The Effectiveness of 448-kHz Capacitive Resistive Monopolar Radiofrequency for Subcutaneous Fat Reduction in a Porcine Model

  • Kwon, Tae-Rin;Lee, Sung-Eun;Kim, Jong Hwan;Jeon, Yong Jae;Jang, You Na;Yoo, Kwang Ho;Kim, Beom Joon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.64-73
    • /
    • 2019
  • Background and Objectives The effectiveness of many physiotherapy modalities in reducing subcutaneous fat has been investigated in numerous previous studies. However, to the best of our knowledge, there have been no attempts to determine the effectiveness of physiotherapy modalities in body contouring. The present report determined the effect of 448-kHz capacitive resistive monopolar radiofrequency (CRMRF) in a porcine model. Materials and Methods This study investigated the effect of selective destruction of the subcutaneous fat layer in abdominal fat tissue using CRMRF. The effects of two types of CRMRF (capacitive electric transfer (CET) and resistive electric transfer (RET)) treatment were evaluated using regular digital photography in addition to thermal imaging evaluation, ultrasound measurement, hematological evaluation, and histologic analyses (H&E (hematoxylin and eosin), Oil red O, and immunohistochemistry staining). Results Preclinical evaluation was performed to obtain the data for comparison of the safety and efficacy of the subcutaneous fat reduction after applying CRMRF using CET and RET. After treatment, the thermal transmission was effective, and a 42-47℃ temperature change was observed in the fat layer while an approximately temperature of 42℃ was confirmed on the skin surface. Moreover, after the application of both types of CRMRF treatment, fibrotic septa were observed in the adipose tissue induced by heat at the treatment sites. TUNEL staining was also performed to confirm the process of apoptosis in the adipocytes. Conclusion These results suggest that both CET and RET for CRMRF treatment are safe and effective for subcutaneous fat reduction in a porcine model.

The Spectrum of Laser Instruments for Laser Acupuncture Application (레이저침 시술에 사용되는 레이저 기기의 적용 범위에 대한 고찰)

  • Hwang, Eui-Hyoung;Yang, Chang-Sop;Jang, In-Soo
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • Objectives : During the past three decades there has been a significant evolution of laser acupuncture application in the nature of the clinical approach and the research of traditional medicine and laser therapy field. However, there have been no standard and guideline of laser equipment can be applied as laser acupuncture. This study aims to investigate the condition of laser equipment required as a laser acupuncture method. Methods : First, we performed literature search using the Medline(from 1999 to Oct 2008) to confirm types and ranges of laser equipments that can be applied as laser acupuncture. In addition, we investigated the characters of acupoints such as sites and depths, and compared with penetrating depths of each laser. Results : A total of 37 articles for clinical studies using laser acupuncture were selected, and 41 lasers were used. GaAs laser was used three times, GaAlAs laser 14, InGaAlP 18, HeNe laser 4, and Argon laser and CO2 laser were used one time, respectively. From all 361 points of fourteen meridians, depths of 341 points(94.5%) were 1 cun(2.3-3.2cm) or less. The mean depth of all points was 0.48 cun(1.1-1.5cm). Hence, it appeared that the majority of therapeutic lasers satisfied with the condition. HeNe, InGaAlP, GaAlAs, GaAs lasers are recommended for laser acupuncture, however, it may plausible that other surgical lasers could be used as the laser acupuncture, because it have the biostimulation effect to some extent, too. Conclusions : It is suggested that to select appropriate laser type and give the adequate output power to reach the acupoints under the skin using laser acupuncture. Further evaluation and research for the condition of laser acupuncture are warranted.

  • PDF

Management of Reproduction on Small, Medium and Large Rabbit Farms: A Review

  • Szendro, Zs.;Szendro, K.;Zotte, A. Dalle
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.5
    • /
    • pp.738-748
    • /
    • 2012
  • One of the main goals of small, medium and large farms is to improve the reproductive performance of rabbit does. Stocks of lower productivity can be improved by crossing with intensive breeds. A better nutritional status of both foetuses and suckling kits has a positive effect on their later productivity. Overfeeding young females before first mating can lead to conditions of fattiness. Using restricted feeding or higher fibre content in the feed and changing it for a higher level ad libitum feeding about one week prior to first mating leads to longer lifespan and higher productive level. Intensive reproductive rhythm creates a negative energy balance in does : they are unable to consume enough feed (energy) for the nutritional requirements of foetus and lactation, and therefore lose most of their fat reserves. Furthermore, primiparous does also expend energy because they are still growing. Under intensive conditions, the 42-d reproductive rhythm (re-mating 11 days after parturition) is recommended. Under extensive conditions, the 18 or 25-d mating interval with 35 to 42-d weaning could be suitable. On small farms, natural mating is favoured; on large farms AI is commonly employed. The main advantage of AI is the all-in, all-out system. Hormonal (PMSG) treatment is used with AI to increase receptivity on d 11. Frequent and high level PMSG use can lead to higher anti-PMSG antibody rates. Lower level (max. 20 IU) and less frequent PMSG injection or non-hormonal alternative methods (short dam-litter separation, changing nursing method or lighting programs) are recommended for this reason.

Evidences of in Situ Remediation from Long Term Monitoring Data at a TCE-contaminated Site, Wonju, Korea

  • Lee, Seong-Sun;Kim, Hun-Mi;Lee, Seung Hyun;Yang, Jae-Ha;Koh, Youn Eun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.8-17
    • /
    • 2013
  • The contamination of chlorinated ethenes at an industrial complex, Wonju, Korea, was examined based on sixteen rounds of groundwater quality data collected from 2009 to 2013. Remediation technologies such as soil vapor extraction, soil flushing, biostimulation, and pumping-and-treatment have been applied to eliminate the contaminant sources of trichloroethylene (TCE) and to prevent the migration of TCE plume from remediation target zones. At each remediation target zone, temporal monitoring data before and after the application of remediation techniques showed that the aqueous concentrations of TCE plume present at and around the main source areas decreased significantly as a result of remediation technologies. However, the TCE concentration of the plumes at the downstream area remained unchanged in response to the remediation action, but it showed a great fluctuation according to seasonal recharge variation during the monitoring period. Therefore, variations in the contaminant flux across three transects were analyzed. Prior to the remediation action, the concentration and mass discharges of TCE at the transects were affected by seasonal recharge variation and residual DNAPLs sources. After the remediation, the effect of remediation took place clearly at the transects. By tracing a time-series of plume evolution, a greater variation in the TCE concentrations was detected at the plumes near the source zones compared to the relatively stable plumes in the downstream. The difference in the temporal profiles of TCE concentrations between the plumes in the source zone and those in the downstream could have resulted from remedial actions taken at the source zones. This study demonstrates that long term monitoring data are useful in assessing the effectiveness of remediation practices.