• Title/Summary/Keyword: Biosignal

Search Result 117, Processing Time 0.019 seconds

Automatic measurement of voluntary reaction time after audio-visual stimulation and generation of synchronization signals for the analysis of evoked EEG (시청각자극 후의 피험자의 자의적 반응시간의 자동계측과 유발뇌파분석을 위한 동기신호의 생성)

  • 김철승;엄광문;손진훈
    • Science of Emotion and Sensibility
    • /
    • v.6 no.4
    • /
    • pp.15-23
    • /
    • 2003
  • Recently, there have been many attempts to develop BCI (brain computer interface) based on EEG (electroencephalogram). Measurement and analysis of EEG evoked by particular stimulation is important for the design of brain wave pattern and interface of BCI. The purpose of this study is to develop a general-purpose system that measures subject's reaction time after audio-visual stimulation which can work together with any other biosignal measurement systems. The entire system is divided into four modules, which are stimulation signal generation, reaction time measurement, evoked potential measurement and synchronization. Stimulation signal generation module was implemented by means of Flash. Measurement of the reaction time (the period between the answer request and the subject reaction) was achieved by self-made microcontroller system. EEG measurement was performed using the ready-made hardware and software without any modification. Synchronization of all modules was achieved by, first, the black-and-white signals on the stimulation screen synchronized with the problem presentation and the answer request, second, the photodetectors sensing the signals. The proposed method offers easy design of purpose-specific system only by adding simple modules (reaction time measurement, synchronization) to the ready-made stimulation and EEG system, and therefore, it is expected to accelerate the researches requiring the measurement of evoked response and reaction time.

  • PDF

Analyzing drivers' visual response variation in very long expressway tunnel ; the Yuksimnyeong tunnel (장대터널에서의 운전자 시각각성변화 분석연구 (육십령터널을 대상으로))

  • Kim, Ju-Yeong;Kim, Hyeon-Jin;Jang, Myeong-Sun
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.1
    • /
    • pp.17-25
    • /
    • 2009
  • This research analyzed the changes of drivers' visual workload with beta wave of bionic signals from brain's occipital lobe from entrance to exit section of the Yuksimnyeong tunnel which is 3.1km long in Daejeon-Tongyeong section of Jungbu expressway. There are 10 subjects who Participate our experiments and the results are as follows. First. the drivers' visual workload is higher about 41% in entrance section of the tunnel than 200m in advance of the section of the tunnel. Second, it is higher than 200m in advance of the section of the tunnel by 34.5% that the value of the drivers' visual workload who is driving in the tunnel. Third, as a result of analyzing the tunnel into 200m unit section, it is statistically different from other sections' at the 1.0km and 2.4km section from the entrance of the tunnel. If drivers sustain average visual workload for safe driving in very long tunnel, it's not desirable environment that drivers' visual workload goes under the average workload. Therefore, it would be the section where drivers who is driving in tunnel could cause a traffic accident.

Development of Individually Adapted Electromagnetic Therapy System in Incontinence (환자 맞춤형 전자기장 요실금 치료 시스템 개발)

  • Noh, Si-Cheol;Kang, Kyu-Hong;Lee, Jeong-Seok;Min, Kwon-Sik;Kwon, Jang-Woo;Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.51-59
    • /
    • 2008
  • Incontinence is the urination disorder as the leakage of urine without her own volition and the woman's representative disease which reduce the life quality. The electromagnetic therapy has high possibility of development cause it has no needs of operant exercise, no arousing of shame and impossibility of infection. But, it has improvement points such as uniformity of the treatment protocol, patient dependance and absent of patient monitoring system. With these demands, the system which stimulate the pelvic flaw muscle with electromagnetic and monitoring the patient status during the therapy is proposed, in this study. And individually adapted electromagnetic therapy system for incontinence patient is also suggested. The proposed system consisted of electromagnetic generation device, cooling device, treating chair, patient monitoring device with pulsation and control software. The simulation for high power system and evaluation confirm was performed. With the development of control software, the convenience of using and maintenance are ensured and the patient adapted therapy protocol is applied. The developed patient adapted electromagnetic therapy system with monitoring device is regarded as the patient affinitive treating method by reducing the riskiness, improving the efficiency with patterned protocol and pre/post therapy. These results, in this study, can bring the safe and organized treatment method to incontinence patients and can lead the variable study for electromagnetic therapy in incontinence.

Analysis of the Necessary Mechanical Properties of Embroiderable Conductive Yarns for Measuring Pressure and Stretch Textile Sensor Electrodes (생체 신호 측정 압력 및 인장 직물 센서 전극용 자수가 가능한 전도사의 필요 물성 분석)

  • Kim, Sang-Un;Choi, Seung-O;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.49-56
    • /
    • 2021
  • In this study, we investigated the necessary mechanical properties of conductive multifilament yarns for fabricating the electrodes of biosignal measurement pressure and stretch textile sensors using embroidery. When electrodes and circuits for smart wearable products are produced through the embroidery process using conductive multifilament yarns, unnecessary material loss is minimized, and complex electrode shapes or circuit designs can be produced without additional processes using a computer embroidering machine. However, because ordinary missionary threads cannot overcome the stress in the embroidery process and yarn cutting occurs, herein, we analyzed the S-S curve, thickness, and twist structure, which are three types of silver-coated multifilament yarns, and measured the stress in the thread of the embroidery simultaneously. Thus, the required mechanical properties of the yarns in the embroidery process were analyzed. In the actual sample production, cutting occurred in silver-coated multifilament rather than silver-coated polyamide/polyester, which showed the lowest S-S curve. In the embroidery process, the twist was unwound through repetitive vertical movement. Further, we fabricated a piezoresistive pressure/tension sensor to measure gauge factor, which is an index for measuring biological signals. We confirmed that the sensor can be applied to the fabrication of embroidery electrodes, which is an important process in the mass production of smart wearable products.

Implementation of Acceleration Sensor-based Human activity and Fall Classification Algorithm (가속도 센서기반의 인체활동 및 낙상 분류를 위한 알고리즘 구현)

  • Hyun Park;Jun-Mo Park;Yeon-Chul, Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.76-83
    • /
    • 2022
  • With the recent development of IT technology, research and interest in various biosignal measuring devices is increasing. As an aging society is in full swing, research on the elderly population using IT-related technologies is continuously developing. This study is about the development of life pattern detection and fall detection algorithm, which is one of the medical service areas for the elderly, who are rapidly developing as they enter a super-aged society. This study consisted of a system using a 3-axis accelerometer and an electrocardiogram sensor, collected data, and then analyzed the data. It was confirmed that behavioral patterns could be classified from the actual research results. In order to evaluate the usefulness of the human activity monitoring system implemented in this study, experiments were performed under various conditions, such as changes in posture and walking speed, and signal magnitude range and signal vector magnitude parameters reflecting the acceleration of gravity of the human body and the degree of human activity. was extracted. And the possibility of discrimination according to the condition of the subject was examined by these parameter values.

CNN-LSTM-based Upper Extremity Rehabilitation Exercise Real-time Monitoring System (CNN-LSTM 기반의 상지 재활운동 실시간 모니터링 시스템)

  • Jae-Jung Kim;Jung-Hyun Kim;Sol Lee;Ji-Yun Seo;Do-Un Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.134-139
    • /
    • 2023
  • Rehabilitators perform outpatient treatment and daily rehabilitation exercises to recover physical function with the aim of quickly returning to society after surgical treatment. Unlike performing exercises in a hospital with the help of a professional therapist, there are many difficulties in performing rehabilitation exercises by the patient on a daily basis. In this paper, we propose a CNN-LSTM-based upper limb rehabilitation real-time monitoring system so that patients can perform rehabilitation efficiently and with correct posture on a daily basis. The proposed system measures biological signals through shoulder-mounted hardware equipped with EMG and IMU, performs preprocessing and normalization for learning, and uses them as a learning dataset. The implemented model consists of three polling layers of three synthetic stacks for feature detection and two LSTM layers for classification, and we were able to confirm a learning result of 97.44% on the validation data. After that, we conducted a comparative evaluation with the Teachable machine, and as a result of the comparative evaluation, we confirmed that the model was implemented at 93.6% and the Teachable machine at 94.4%, and both models showed similar classification performance.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.