• Title/Summary/Keyword: Bioprosthesis

Search Result 56, Processing Time 0.017 seconds

A Bicentric Propensity Matched Analysis of 158 Patients Comparing Porcine Versus Bovine Stented Bioprosthetic Valves in Pulmonary Position

  • Bunty Ramchandani;Raul Sanchez;Juvenal Rey;Luz Polo;Alvaro Gonzalez;Maria-Jesus Lamas;Tomasa Centella;Jesus Diez;Angel Aroca
    • Korean Circulation Journal
    • /
    • v.52 no.8
    • /
    • pp.623-631
    • /
    • 2022
  • Background and Objectives: Pulmonary valve replacement (PVR) is the most common operation in adults with congenital heart disease (CHD). There is controversy regarding the best bioprosthesis. We compare the performance of stented bioprosthetic valves (the Mosaic [MedtronicTM] porcine pericardial against Carpentier Perimount Magna Ease [EdwardsTM] bovine) in pulmonary position in patients with CHD. Methods: Between January 1999 and December 2019, all the PVRs were identified from hospital databases in 2 congenital heart centres in Spain. Valve performance was evaluated using clinical and echocardiographic criteria. Propensity score matching was used to balance the 2 treatment groups. Results: Three hundred nineteen patients were retrospectively identified. After statistical adjustment, 79 propensity-matched pairs were available for comparison Freedom from reintervention for the porcine cohort was 98.3%, 96.1%, and 91.9% at 3, 5, and 10 years and 100%, 98%, and 90.8% for the bovine cohort (p=0.88). Freedom from structural valve degeneration (SVD) for the porcine cohort was 96.9%, 92.8% and 88.7% at 3, 5, and 10 years and 100%, 98%, and 79.1% for the bovine cohort (p=0.38). Bovine prosthesis was associated with a reintervention hazard ratio (HR), 1.12; 95% confidence intervals (CIs), 0.24-5.26; p=0.89 and SVD HR, 1.69 (0.52-5.58); p=0.38. In the first 5 years, there was no difference in outcomes. After 5 years, the recipients of the bovine bioprosthesis were at higher risk for SVD (reintervention HR, 2.08 [0.27-16.0]; p=0.49; SVD HR, 6.99 [1.23-39.8]; p=0.03). Conclusions: Both bioprosthesis have similar outcomes up to 5 years, afterwards, porcine bioprosthesis seem to have less SVD.

Risk Factors of Redo-valve Replacement (판막재치환술의 위험인자)

  • 최강주;조광현;김성룡;이상권;전희재;윤영철;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.785-791
    • /
    • 2002
  • The results of reoperative valve replacement can be improved if appropriate analysis for the risk of reoperation was achieved. The purpose of our study was to analyze the results of reoperations for failure of bioprosthesis, and to define the risk factors in high-risk populations for reoperative procedures. Material and Method The series of 46 consecutive patients who had undergone first reoperative replacement for failed bioprosthesis between 1993 and 2001 were reviewed retrospectively. Mean age was 42 $\pm$ 12 years, mean body surface area was 1.52 $\pm$0.15 $m^2$. The reoperative procedure comprised of 36 MVR, 8 DVR, and 2 AVR. The first operation comprised of 2 DVR, 1 AVR, and 43 MVR. Factors which were choose to assess a predictor of results in reoperative valve replacement were sex, old age(>60 years), early age at first operation(<30 years), long interval between first and redo operation(.15years), poor NYHA functional class(>3), LV dysfunction(LVEF<45%), long operation time(>8hours), endocarditis, combined procedures, and renal insufficiency, Result : Overall mortality was 4.3%(2 cases). The risk factors that influenced postoperative complications and unexpected postoperative results were lower ejection fraction(p=0.012), older age(p=0.045), endocarditis(p=0.023), long operation time above 8 hours(p=0.027). There was no statistically significant factor influencing hospital mortality. Conclusion : No factor influenced the mortality. Better results could be achieved if reoferation was performed carefully in poor left ventricular function, old aged patient, and with endocarditis. Effort to shorten the operation time would be helpful on postoperative results.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Comparative Study of Durability of Bioprosthetic Valve Considering Age of Patients (Ionescue-Shiley 조직판막의 환자 연령군에 따른 내구성에 관한 비교연)

  • 김진국
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.673-682
    • /
    • 1987
  • The principal feature of bioprosthetic valve which remains to be completely defined is long-term durability, especially, with regard to the impact of patient age. This report provides extended data regarding valve durability derived from a data base of 515 patients who received lonescu-Shiley bioprosthetic valve between 1978 and 1985; cumulative duration of follow-up was 1562.3 patient-years, with a maximum follow-up duration of 8.7 years. The results of this survey showed as follows: 1] The actuarial freedom from valve failure at 6 years were 43*7% for 0-19 year-old group, 70*1% for 20-39 year-old group and 75*1% for over 40 year-old group separately. 2] Of the causes of valve failure, only the primary tissue failure was markedly influenced by patient`s age [p<0.001], but the prosthetic valve endocarditis was not [p>0.1]. 3] The linealized incidences of primary tissue failure were 7.31% per patient-year in 0-19 year-old group and 0.12% in 20-39 year-old group. 4] The primary tissue failure rate in 0-19 year-old group was 6.36% during first 4 years, but then increased upto 10.95% at postoperative 5 year. Thus we find that in bioprosthetic valve the primary tissue failure is apt to occur when patient is young [especially less than 20 years old] and the postreplacement time passes [especially over 5 years]. The rate of bioprosthesis failure among children and adolescents is clearly higher than that observed in adult patients; however, conclusive quantification of time-related risk for young patient is not yet possible on the basis of existing data. Therefore, the advisability of bioprosthesis implantation in children remains to be determined.

  • PDF

Histologic Characteristics and Mechanical Properties of Bovine Pericardium Treated with Decellularization and ${\alpha}$-Galactosidase: A Comparative Study

  • Min, Byoung-Ju;Kim, Yong Jin;Choi, Jae-Woong;Choi, Sun Young;Kim, Soo Hwan;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.45 no.6
    • /
    • pp.368-379
    • /
    • 2012
  • Background: Bioprostheses for cardiovascular surgery have limitations in their use following as calicification. ${\alpha}$-galactosidase epitope is known as a stimulant of immune response and then shows a progressing calcification. The objective of this study was to evaluate histologic characteristics and mechanical properties of decellularization and treated with ${\alpha}$-galactosidase. Materials and Methods: Bovine pericardial tissues were allocated into three groups: fixation only with glutaraldehyde, decellularization with sodium dodesyl sulfate and decellularization plus treatment with ${\alpha}$-galactosidase. We confirmed immunohistological characteristics and mechanical properties as fatigue test, permeability test, compliance test, tensile strength (strain) test and thermal stability test. Results: Decellularization and elimination of ${\alpha}$-gal were confirmed through immunohistologic findings. Decellularization had decreased mechanical properties compared to fixation only group in permeability (before fatigue test p=0.02, after fatigue test p=0.034), compliance (after fatigue test p=0.041), and tensile strength test (p=0.00). The group of decellularization plus treatment with ${\alpha}$-galactosidase had less desirable mechanical properties than the group of decellularization in concerns of permeability (before fatigue test p=0.043) and strain test (p=0.001). Conclusion: Favorable decellularization and elimination of ${\alpha}$-gal were obtained in this study through immunohistologic findings. However, those treatment including decellularization and elimination of ${\alpha}$-gal implied the decreased mechanical properties in specific ways. We need more study to complete appropriate bioprosthesis with decellularization and elimination of ${\alpha}$-gal including favorable mechanical properties too.

Clinical Midterm Results of Surgical Aortic Valve Replacement with Sutureless Valves

  • Soonchang Hong;Jung-Woo Son;Yungjin Yoon
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Sutureless aortic valves may enable shorter procedure times, which benefits patients with elevated surgical risk. We describe the outcomes of patients with aortic stenosis who underwent aortic valve replacement (AVR) using the sutureless Perceval aortic bioprosthesis. Methods: Data from a retrospective cohort were obtained from a clinical database. The study enrolled patients with symptomatic severe aortic stenosis who underwent surgical AVR with a sutureless bioprosthesis between August 2015 and December 2020. In total, 113 patients were included (mean age, 75.3±8.4 years; 57.5% women; median Society of Thoracic Surgeons score, 9.7%; mean follow-up period, 51.19±20.6 months). Of these patients, 41 were octogenarians (36.2%) and 3 were nonagenarians (2.6%). Transthoracic echocardiography was employed to assess changes in ejection fraction (EF), left ventricular mass index (LVMI), and mean pressure gradient (MPG). Results: The in-hospital mortality rate was 2.6%, and 13 patients developed new-onset atrial fibrillation. A permanent pacemaker was implanted in 3 patients (2.6%). The median intensive care unit stay was 1 day (interquartile range [IQR], 1-2 days), and the median hospital stay was 12 days (IQR, 9.5-15 days). The overall survival rate at 5 years was 95.9%. LVMI and MPG were reduced postoperatively, while EF increased over the follow-up period. No structural valve deterioration was observed, and no meaningful paravalvular leakage developed during follow-up. Conclusion: The use of a sutureless valve in the aortic position is safe and feasible, even for high-risk elderly patients requiring surgical AVR. LVMI and MPG decreased postoperatively, while EF increased over the follow-up period.

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

The Surgical management of Ebstein's anomaly: A Report of 4 cases of tricuspid valve replacement and plication of the atrialized right ventricle (Ebstein 심기형의 개심술 4례 (삼첨판막 대치이식술 및 우심실 Plication))

  • Im, Seung-Pyeong;Yang, Gi-Min;Lee, Yung-Kyoon
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.435-441
    • /
    • 1980
  • Ebstein`s anomaly had been amenable to reparative surgery since 1962. However, neither the role of surgery in Ebstein`s anomaly nor the surgical procedure of choice for its correction are clearly defined. Whether or not the atrialized right ventricle, which plays a major role in the functional abnormalities, should be obliterated in all cases remains unsolved. Four cases of Ebstein`s anomaly treated surgically at Seoul National University Hospital were reported. All had closure of the atrial septal defect, obliteration of the atrialized right ventricle by plication, and insertion of a tricuspid bioprosthesis and an epicardial ventricular pacemaker. One patient had a pulmonic valvotomy due to stenotic bicuspid pulmonic valve also. All but one had discharged with a good result.

  • PDF

Clinical Experience of Cardiovascular Surgery : A Report Of 2032 Cases (심장 혈관질환 2032 수술 례 보고)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.375-384
    • /
    • 1980
  • Since 1958 up to the end of October 31, 1980, 2032 cases of cardiovascular lesions were operated, including 1225 open heart surgery and 354 valve replacement patients. There were 1271 Congenital anomaly cases and 761 acquired lesions including 149 vascular lesions. Among 1~271 congenital malformations 819 cases belong to acyanotic and 452 to cyanotic group. Over all mortality was 11.1 %, consisting of 12.4% for congenital and 8.9% for acquired lesions. Mortality for 1225 open heart surgery cases was 15% and 13.8% for various 354 valve replacement cases. In most of the open heart surgery cases Shiley oxygenator was utilized and Ionescu-Shiley bovine pericardial xenograft bioprosthesis**** valves were used mainly for valve replacement.

  • PDF

Annuloaortic Ectasia Associated with Aortic Regurgitation (One case report) (Annuloaortic Ectasia 의 치험 1례 보고)

  • 이정호
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.238-242
    • /
    • 1982
  • The incidence of annuloaortic ectasia has known rare, and approximately 5-10% of aortic regurgitation. The patient was 44 years old male who complained exertional dyspnea and left anterior chest pain. He had done Lt. side 2 stage thoracoplasty for pulmonary tuberculosis about 20 years ago at Dept.of Chest surgery of National Medical Center. At that time, there was no abnormal findings in cardiovascular system. The preoperative aortic cineangiogram showed pear shaped dilatation [7.3 cm x 6.8 cm] of aortic mot with aortic valve regurgitation but left ventricular ejection function was fair. Preop. ventilatory function test showed mixed type pulmonary insufficiency. Recently, we corrected surgically, by AVR with Carpentier-Edwards Bioprosthesis [29mm] & supracoronary Woven Dacron graft [29mm x 5cm] replacement, with good clinical result for follow up 6 months.

  • PDF