• Title/Summary/Keyword: Biomedical devices

Search Result 424, Processing Time 0.023 seconds

Bombyx mori Silk Fibroin Films: Preparation, Characterization of Physical and Chemical Properties, Use as Biomaterial

  • Freddi, Giuliano
    • Proceedings of the Korean Society of Sericultural Science Conference
    • /
    • 2003.10a
    • /
    • pp.34-38
    • /
    • 2003
  • The silk fibre Produced by the larvae of the lepidopter of the Bombyx mori species is no doubt one of the most precious raw materials employed in manufacturing textile products. The present report, however, deals with silk not as a traditional textile fibre, but as a starting material fer biomedical applications. In recent years, the unique chemical and mechanical properties of silk have made this protein polymer highly attractive for innovative applications, which mainly focus on the development of devices for biomedical uses. (omitted)

  • PDF

Establish Selection Process of Performance Management Medical Devices and Test items Based on Risk Management (위험관리기반의 성능관리 의료기기 선정 절차 수립 및 시험 항목 도출)

  • Park, Ho Joon;Jang, Joong Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.20-31
    • /
    • 2019
  • Medical device performance management is an activity that allows a device to be safely used and maintained even after it is put on the market. The purpose of this study is to provide procedures and criteria for selection of medical device items that should manage the safety and performance among medical devices in hospital. Investigate the performance management status of medical devices in hospitals and identify the performance management status by domestic and advanced regulatory agencies. Provides selection procedures and test methods for medical devices subject to performance management in hospitals based on medical device risk management and reliability. In addition, a case study on drug infusion pumps was conducted.

Multi-channel Unconstrained Heart Rate Monitoring System for Exercising Rehabilitation Patients (재활 훈련중인 환자를 위한 다채널 무구속 심박동수 모니터링 시스템)

  • Cho, J.M.;Choi, J.H.;Park, J.H.;Nam, T.W.;Eun, J.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • This research focused on the development of wireless telemetry system that can monitor heart rates of multiple rehabilitation patients in real time without constraint. The whole system consists of the multiple patient's side devices (PSDs) and one central monitoring system (CMS). The PSD consists of a microphone, amplifier, filter, microcontroller, and RF (Radio Frequency) modem. In addition, the PSD was designed to be wearable and low power consumption. The CMS consists of an RF modem and general PC and it was designed to monitor heart rates from multiple patients simultaneously. The system warns an alarm signal when a patient's heart rate exceeds the pre-set range for each patient. This system can be useful to monitor the heart rate of exercising rehabilitation patients and control the patients condition and the exercising level.

Evaluation of Standing Balance of the Elderly with Different Balance Abilities by using Kinect and Wii Balance Board

  • Yang, Seung Tae;Seo, Jung Woo;Kim, Dae Hyeok;Kang, Dong Won;Choi, Jin Seung;Tack, Gye Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.391-396
    • /
    • 2016
  • Objective: This study aimed to evaluate and identify variables for the standing balance of elderly subjects with different balancing abilities by using Kinect and Wii Balance Board. Method: The Berg Balance Scale (BBS) test was performed in 40 elderly subjects aged ${\geq}65years$ who can perform daily activities. The participants were divided into two groups, the healthy seniors (n = 20, BBS score ${\geq}52$) and the seniors with balancing problems (n = 20, BBS score < 52). Each group performed two standing tests (eyes open and eyes close) with two devices (Kinect and Wii Balance Board). The root mean square (RMS), mean distance (MDIST), range of distance (ROD), mean velocity, and 95% ellipse area were calculated from the measured data. Results: Among the calculated variables, RMS, MDIST, and ROD in the mediolateral direction showed significant differences between the two groups and a negative correlation with BBS scores. Conclusion: The results of the present study show that simple standing balance of the elderly can be measured with Kinect and Wii Balance Board, which are low-cost, easy to carry, and easy to use, by using the selected variables.

Implementation of a Transcutaneous Power Transmission System for Implantable Medical Devices by Resonant Frequency Tracking Method (주파수 추적 방식에 의한 이식형 의료기기용 무선전력전달 장치 구현)

  • Lim, H.G.;Lee, J.W.;Kim, D.W.;Lee, J.H.;Seong, K.W.;Kim, M.N.;Cho, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.401-406
    • /
    • 2010
  • Recently, many implantable medical devices have been developed and manufactured in many countries. In these devices, generally, energy is supplied by a transcutaneous method to avoid the skin penetration due to the power wires. As the most transcutaneous power transmission methods, the electromagnetic coupling between two coils and resonance at a specific frequency has been used widely. However, in case of a transcutaneous power transmitter with a fixed switching frequency to drive an electromagnetic coil, inefficient power transmission and thermal damage by the undesirable current variation may occur, because the electromagnetic coupling state between a primary coil and a secondary coil is very sensitive to skin thickness of each applied position and by person. In order to overcome these defects, a transcutaneous power transmitter of which operating frequency can be automatically tracked into the resonance frequency at each environment has been designed and implemented. Through the results of experiments for different coil surroundings, we have been demonstrated that the implemented transcutaneous power transmitter can track automatically into a varied resonance frequency according to arbitrary skin thickness change.

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF

Position Recognition and User Identification System Using Signal Strength Map in Home Healthcare Based on Wireless Sensor Networks (WSNs) (무선 센서네트워크 기반 신호강도 맵을 이용한 재택형 위치인식 및 사용자 식별 시스템)

  • Yang, Yong-Ju;Lee, Jung-Hoon;Song, Sang-Ha;Yoon, Young-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.494-502
    • /
    • 2007
  • Ubiquitous location based services (u-LBS) will be interested to an important services. They can easily recognize object position at anytime, anywhere. At present, many researchers are making a study of the position recognition and tracking. This paper consists of postion recognition and user identification system. The position recognition is based on location under services (LBS) using a signal strength map, a database is previously made use of empirical measured received signal strength indicator (RSSI). The user identification system automatically controls instruments which is located in home. Moreover users are able to measures body signal freely. We implemented the multi-hop routing method using the Star-Mesh networks. Also, we use the sensor devices which are satisfied with the IEEE 802.15.4 specification. The used devices are the Nano-24 modules in Octacomm Co. Ltd. A RSSI is very important factor in position recognition analysis. It makes use of the way that decides position recognition and user identification in narrow indoor space. In experiments, we can analyze properties of the RSSI, draw the parameter about position recognition. The experimental result is that RSSI value is attenuated according to increasing distances. It also derives property of the radio frequency (RF) signal. Moreover, we express the monitoring program using the Microsoft C#. Finally, the proposed methods are expected to protect a sudden death and an accident in home.

Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film (졸-겔 필름을 이용한 반사형 광섬유 pH 센서의 개발)

  • Yoo, Wook-Jae;Seo, Jeong-Ki;Jang, Kyoung-Won;Moon, Jin-Soo;Han, Ki-Tek;Park, Jang-Yeon;Lee, Bong-Soo;Cho, Seung-Hyun;Heo, Ji-Yeon;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.266-271
    • /
    • 2011
  • A reflection-type fiber-optic pH sensor, which is composed of a pH sol-gel film, plastic optical fibers, a mirror, a light source and a spectrometer, is developed in this study. As pH indicators, a bromthymol blue, a cresol red and a thymol blue are used, and they are immobilized in the sol-gel films. The emitted light from a light source is guided by a fiber-optic Y-coupler and plastic optical fibers to the pH sol-gel film in a pH sensing probe. The pH change in the sensing probe gives rise to a change in the color of the pH sol-gel film, and the optical characteristic of reflected light through the pH sol-gel film is also changed. Therefore, we have measured the spectra of reflected lights, which are changed according to the color variations of the pH sol-gel films with different pH values, by using of a spectrometer. Also, the relationships between the pH values and the intensities of reflected lights are obtained on the basis of the color variations of the pH sol-gel films.

Nanomagnetics-biomedical Convergence for Next Generation Biomedical Assays (나노자성-바이오.메디컬 컨버젼스 연구)

  • Kim, Cheol-Gi
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.4
    • /
    • pp.167-172
    • /
    • 2010
  • To meet on going challenges in nano-biomedical technology, the convergence of "spintronics", "biomedical" technology is a major break through in imaging, diagnosis and therapy, high-throughput genomic analysis. Especially magnetic bioassay is one of crucial devices for early diagnosis of specific analytes, point-of-care and U-health care application. In this paper, current status on high resolution magnetic sensors for bioassay and on-chip magnets for biomolecule transportation will be reviewed.

Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device (휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발)

  • Lee, Eun-Mi;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.