• Title/Summary/Keyword: Biomedical devices

검색결과 424건 처리시간 0.026초

의료용 전기 접점부의 마이크로 레이저 용접 (LASER MICROWELDING FOR ELECTRICAL INTERCONNECTION IN BIOMEDICAL TECHNOLOGY)

  • 깁재웅
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 추계학술발표대회 개요집
    • /
    • pp.45-48
    • /
    • 2003
  • Over the past few decades, there has been increasing research and commercial activity in invasive and non-invasive biomedical technology. One important challenge to developing these devices involves the increasing density of electrical interconnects. Resistance spot welding is limited in the density of interconnect based on either the size of welding head or the positional precision with which a weld can be made. Development of an automated laser microwelding system would permit the continued advancement of these important biomedical technologies. The objective of this work is to demonstrate the application of pseudo-pulse Nd:YAG laser technology as an alternative to resistance spot welding in performing electrical interconnection within biomedical products. To date, some experiments have been conducted by using a pseudo-pulse 1064 nm Nd:YAG laser, a successful weld of a 25 ${\mu}{\textrm}{m}$ diameter Pt/Ir wire to a 316 stainless steel shim can be made. Another application involves welding clips, which may be used for external interconnection, to electrodeposited nickel domes that make particular interconnections to specific insulated wires within a cable. These results show a great deal of promise for developing such a process.

  • PDF

의료기기 고장 발생의 원인 분석을 통한 효과적인 보수유지 방법의 개선 (Effective Maintenance of Medical Device through System Failure Analysis)

  • 강훈희;김종순;김서확;허수진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.106-107
    • /
    • 1998
  • To minimize the failure rate of medical devices, the maintenance records for general X-ray, R/F X-ray, mobile X-ray, artificial dialyzer, ventilator, and automatic chemistry analyzer was analysed with regard to the cause of the failure. The parts responsible for the most frequent system failure was then worked intensively during the preventive maintenance. After this procedure, the faliure of the systems in a month decreased from 1.8 on average to 0.3.

  • PDF

전기유압식 좌심실보조기에 사장된 직류서보모터의 슬라이딩모드 제어 (Sliding Mode Control of DC Servo Motor in Electrohydraulic Ventricuar Assist Devices)

  • 안윤호;최재순;정찬일;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.78-81
    • /
    • 1995
  • 본 연구에서는 슬라이딩 모드를 전기유압식 심실보조기의 직류모터제어기의 속도와 위치제어에 적용하였다. 슬라이딩 모드 컨트롤은 가변구조시스템(varaiable sturucture system)의 일종으로 적절한 내부스위칭 논리를 갖는 연속적인 부시스템(subsystem)의 모임으로 구성된다는 접에서 고정된 제어구조를 갖는 일반적인 제어시스템과 다르다. 이 시스템은 불연속적인 동적시스템이나 시변적인 요소를 갖는 시스템등에서 사용되고 있다. 이 논문에서는 슬라이딩 모드 제어를 적용하여 좌심실보조기를 제어하는 경우에 넓은 작동범위에서도 시스템이 안정적이며 혈류역학적인 외란에 대해서도 기준입력에 대한 속도의 추종이 잘 이루어지는지의 여부를 실제의 구현에 앞서 컴퓨터모델을 통해 검증하고 문제점들을 조사하였다.

  • PDF

Direct Metal Laser Sintering-New Possibilities in Biomedical Part Manufacturing

  • Kotila, Juha;Syvanen, Tatu;Hanninen, Jouni;Latikka, Maria;Nyrhila, Olli
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.248-249
    • /
    • 2006
  • Direct Metal Laser Sintering (DMLS) has been utilized for prototype manufacturing of functional metal components for years now. During this period the surface quality, mechanical properties, detail resolution and easiness of the process have been improved to the level suitable for direct production of complex metallic components for various applications. The paper will present the latest DMLS technology utilizing EOSINT M270 laser sintering machine and EOSTYLE support generation software for direct and rapid production of complex shaped metallic components for various purposes. The focus of the presentation will be in rapid manufacturing of customized biomedical implants and surgical devices of the latest stainless steel, titanium and cobalt-chromium-molybdenum alloys. In addition to biomedical applications, other application areas where complex metallic parts with stringent requirements are being needed will be presented.

  • PDF

Development of Gait Correction System for Real-Time Gait

  • Kim, Wonsun;Shin, Woojin;Kim, Hyunji;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • 제9권4호
    • /
    • pp.139-148
    • /
    • 2020
  • Walking is one of the most natural and repetitive actions we do in our daily lives. However, many modern people have problems with shoulders, back and spine due to incorrect walking habits. Therefore, it is becoming important to diagnose and correct wrong walking habits, for example, in-toeing, out-toeing, etc. early, which can be a precursor to various diseases. In this study, we developed the system to diagnose and prevent incorrect gait by grasping and analyzing the angle and muscle activity of the foot according to the typical wrong gait type through MPU 6050 acceleration sensor and the surface EMG sensor. Through a smartphone, numerical and visualization screens based on walking can be used to represent the angle of the feet, real-time EMG values, and even the number of steps. The correction effect was enhanced by improving the cognitive ability through a system that allows individuals to easily diagnose gait through smart devices and improve them according to their own problems.

An application of neural network analysis in diagnosis of mechanical failure of a total artificial heart

  • Park, Seong-Keun;Choi, Won-Woo;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.500-504
    • /
    • 1995
  • A neural network based upon the back propagation algorithm was designed and applied to acoustic power spectra of electrohydraulic total artificial hearts in order to diagnose mechanical failure of devices. The trained network distinguished spectra of the mechanically damaged device from those of the undamaged device with overall success rate of 63%. Moreover, the network correctly classified more than 70% of spectra in the frequency bands of 0-100 Hz and 700-950 Hz. Consequently, the neural network analysis was useful for the diagnosis of mechanical failure of a total artificial heart.

  • PDF

Electrical Properties of F16CuPC Single Layer FET and F16CuPc/CuPc Double Layer FET

  • Lee, Ho-Shik;Park, Yong-Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권4호
    • /
    • pp.174-177
    • /
    • 2007
  • We fabricated organic field-effect transistors (OFETs) based a fluorinated copper phthalocyanine ($F_{16}CuPC$) and copper phthalocyanine (CuPc) as an active layer. And we observed the surface morphology of the $F_{16}CuPC$ thin film. The $F_{16}CuPC$ thin film thickness was 40 nm, and the channel length was $50{\mu}m$, channel width was 3 mm. And we also fabricated the $F_{16}CuPc/CuPc$ double layer FET and with different $F_{16}CuPc$ film thickness devices. We observed the typical current-voltage (I-V) characteristics and capacitance-voltage (C-V) in $F_{16}CuPc$ FET and we calculated the effective mobility. From the double layer FET devices, we observed the higher drain current more than single layer FET devices.

언어치료환자를 위한 비음측정기 모듈의 구조가 비음치 산출에 미치는 영향 (Influence of Nasometer Structure on Nasalance for Speech Therapy)

  • 우승탁;박영빈;김주영;오다희;하지완;나승대;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제22권2호
    • /
    • pp.157-166
    • /
    • 2019
  • With the development of medical technology, interest in rehabilitation devices is increasing and various devices are being studied. In particular, devices for speech disorders such as hearing impairment and cleft palate are attracting attention. In general, the nasometer is used for patients with flaccid dysarthria and velopharyngeal incompetence(VPI). However, in the case of the conventional separator type nasometer, that has an acoustic feedback problem between the oral and nasal sounds. In recent, the mask type nasometer has been developed which is insensitive to acoustic feedback. But, still not popularized. In this paper, the nasometer characteristics of the conventional separation type and mask type are analyzed. Also, We were obtained clinical acoustic data from the 6 subjects and examined the significant differences in the structure of the separation type and mask type nasometer. Through experiments, it was confirmed that the measurement was about 3~15% higher in the mask type nasometer than the conventional nasometer having a separator type. Also, We was considered the necessity of nasometer signal processing for acoustic feedback reduction and nasalance calculation optimization.

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF