• Title/Summary/Keyword: Biomedical Monitoring

Search Result 455, Processing Time 0.022 seconds

Research on soil composition measurement sensor configuration and UI implementation (토양 성분 측정 센서 구성 및 UI 구현에 관한 연구)

  • Ye Eun Park;Jin Hyoung Jeong;Jae Hyun Jo;Young Yoon Chang;Sang Sik Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.76-81
    • /
    • 2024
  • Recently, agricultural methods are changing from experience-based agriculture to data-based agriculture. Changes in agricultural production due to the 4th Industrial Revolution are largely occurring in three areas: smart sensing and monitoring, smart analysis and planning, and smart control. In order to realize open-field smart agriculture, information on the physical and chemical properties of soil is essential. Conventional physicochemical measurements are conducted in a laboratory after collecting samples, which consumes a lot of cost, labor, and time, so they are quickly measured in the field. Measurement technology that can do this is urgently needed. In addition, a soil analysis system that can be carried and moved by the measurer and used in Korea's rice fields, fields, and facility houses is needed. To solve this problem, our goal is to develop and commercialize software that can collect soil samples and analyze the information. In this study, basic soil composition measurement was conducted using soil composition measurement sensors consisting of hardness measurement and electrode sensors. Through future research, we plan to develop a system that applies soil sampling using a CCD camera, ultrasonic sensor, and sampler. Therefore, we implemented a sensor and soil analysis UI that can measure and analyze the soil condition in real time, such as hardness measurement display using a load cell and moisture, PH, and EC measurement display using conductivity.

Clinical Efficacy of Real-Time Sonoelastography for the Follow-Up of Congenital Sternocleidomastoid Muscle Torticollis (선천성 근육성 사경의 추적검사에서 실시간 탄성초음파 검사의 임상적 유용성)

  • Mi ri Jeong;In Sook Lee;Yong Beom Shin;You Seon Song;Sekyoung Park;Jong Woon Song;Jin Il Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.176-189
    • /
    • 2020
  • Purpose To evaluate the clinical efficacy of real-time sonoelastography (RTS) for the follow-up of congenital muscular torticollis, based on measurements of muscle elasticity. Materials and Methods Thirty-four infants (23 male, 11 female) with congenital sternocleidomastoid (SCM) muscle torticollis underwent ultrasonography and elastography between November 2012 and December 2014. We evaluated the thickness, morphology (mass-like, fusiform, or overall thickened shape), and echogenicity of the SCM muscle on grayscale images and color patterns (homogeneous blue, mixed green < 50% and ≥ 50%, and green to red) on elastography. Strain ratios were measured using Q-lab software. A clinician classified the degree of neck rotation and side flexion deficits using a 5-point grade system based on angles of neck rotation and side flexion. Correlations between the ultrasonography and clinical findings were evaluated by statistical analysis. Results Twenty-two infants had right and 12 had left SCM torticollis, respectively. Linear regression analysis showed that involved/contralateral SCM thickness differences, morphology, elasticity color scores, and strain ratios of the affected SCM muscles were significantly correlated with neck rotation and side flexion deficit scores (p < 0.05). The elasticity color score of the affected SCM muscle was the most significant factor. Conclusion RTS might provide a reliable means for evaluating and monitoring congenital muscular torticollis.

Highly Sensitive Biological Analysis Using Optical Microfluidic Sensor

  • Lee, Sang-Yeop;Chen, Ling-Xin;Choo, Jae-Bum;Lee, Eun-Kyu;Lee, Sang-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.130-142
    • /
    • 2006
  • Lab-on-a-chip technology is attracting great interest because the miniaturization of reaction systems offers practical advantages over classical bench-top chemical systems. Rapid mixing of the fluids flowing through a microchannel is very important for various applications of microfluidic systems. In addition, highly sensitive on-chip detection techniques are essential for the in situ monitoring of chemical reactions because the detection volume in a channel is extremely small. Recently, a confocal surface enhanced Raman spectroscopic (SERS) technique, for the highly sensitive biological analysis in a microfluidic sensor, has been developed in our research group. Here, a highly precise quantitative measurement can be obtained if continuous flow and homogeneous mixing condition between analytes and silver nano-colloids are maintained. Recently, we also reported a new analytical method of DNA hybridization involving a PDMS microfluidic sensor using fluorescence energy transfer (FRET). This method overcomes many of the drawbacks of microarray chips, such as long hybridization times and inconvenient immobilization procedures. In this paper, our recent applications of the confocal Raman/fluorescence microscopic technology to a highly sensitive lab-on-a-chip detection will be reviewed.

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Multimodal Bio-signal Measurement System for Sleep Analysis (수면 분석을 위한 다중 모달 생체신호 측정 시스템)

  • Kim, Sang Kyu;Yoo, Sun Kook
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.5
    • /
    • pp.609-616
    • /
    • 2018
  • In this paper, we designed a multimodal bio-signal measurement system to observe changes in the brain nervous system and vascular system during sleep. Changes in the nervous system and the cerebral blood flow system in the brain during sleep induce a unique correlation between the changes in the nervous system and the blood flow system. Therefore, it is necessary to simultaneously observe changes in the brain nervous system and changes in the blood flow system to observe the sleep state. To measure the change of the nervous system, EEG, EOG and EMG signal used for the sleep stage analysis were designed. We designed a system for measuring cerebral blood flow changes using functional near-infrared spectroscopy. Among the various imaging methods to measure blood flow and metabolism, it is easy to measure simultaneously with EEG signal and it can be easily designed for miniaturization of equipment. The sleep stage was analyzed by the measured data, and the change of the cerebral blood flow was confirmed by the change of the sleep stage.

The in vivo photothermal treatment of gold nanorod in the mouse ear model

  • Liu, Bruce Yao Wen;Chen, Cheng-Lung;Lee, Shin-Yu;Chang, Fu-Hsiung;Lin, Win-Li;Chia, Chih-Ta;Chen, Yang-Yuan
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.1
    • /
    • pp.41-50
    • /
    • 2014
  • Gold nanorod's exceptional light to heat transduction is a robust phonomenon that has been extensively verified. The phenomenon is a trait from which many novel applications across disciplines have been proposed. In this investigation, the feasibility of utilizing heat harvested from such photothermal method to combat cancer is presented. Using non-invasive laser methods, an in vivo study is conducted on mouse ear tumors administered with gold nanorods (Au NRs). An emphasis is placed on monitoring the tumor developments after photothermal treatments, over time. The findings reveal significant tumor growth surpression at a threshold laser power of $0.6W/cm^2$ lasting 2 minutes; this energy also brought about dramatic size reduction in treated tumors. Furthermore, the apparent formation of an eschar over the laser treated region indicates extensive hemorrhagic necrosis of the tumor tissue; a phenomenon implicative to the inhibition of angiogenesis.

Web based anticancer drug management system using ubiquitous sensor network and RFID (USN과 RFID를 이용한 웹 기반 항암제 관리 시스템)

  • Yoo, Sun-K.;Kim, Soo-Jung;Park, Jung-Jin;Kim, Dong-Keun;Bae, Ha-Su;Chang, Byung-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.229-235
    • /
    • 2008
  • In order to monitor the anticancer drug in stable conditions, the Web based anticancer drug management system and alarm services were constructed and assessed in this study. Anticancer drug should be exact to the correct patient in the right environment. To overcome the restriction of existing equipment that only monitors fragmentarily, temperature and humidity were continuously monitored to maintain stable environments using sensor networks and RFID for the monitoring and management of anticancer drug. Construction drug identification and the effect of normal air outside the anticancer dispensary with obstacles were evaluated in working hour. Pre-installed control system in the dispensary could be alternated with auto sensing and alarming. We expected that the efficiency of anticancer drug management and the reliability of drug medication by handwork would be increase accordingly.

Analysis of Class 1 Integrons in Imipenem-resistant Pseudomonas aeruginosa

  • Sung, Ji Youn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.43 no.2
    • /
    • pp.68-74
    • /
    • 2011
  • Pseudomonas aeruginosa is an aerobic, Gram-negative, glucose-nonfermenting bacterium, which has emerged as a serious opportunistic pathogen. Recently, outbreaks of carbapenem resistant P. aeruginosa give rise to significant therapeutic challenges for treating nosocomial infections. The genes of metallo-${\beta}$-lactamase (MBL), a powerful carbapenemase, are carried as a part of the mobile gene cassettes inserted into integrons playing an important role in rapid dissemination of antibiotic resistance genes among bacterial isolates. In this study, we investigated the prevalence of integron in imipenem resistant P. aeruginosa isolates. A total of 61 consecutive, non-duplicate, and imipenem resistant P. aeruginosa strains were isolated from a university hospital in the Chungcheong province of Korea. We employed repetitive extragenic palindromic sequence-based PCR (rep-PCR) method for the selection of clonally different P. aerusinosa strains. PCR and DNA sequencing were conducted for the detection of integrons. Twenty-one clonally different P. aeruginosa strains were isolated. Only one (P28) of the strains harbored $bla_{VIM-2}$ that was found as gene cassettes in class 1 integrons. Four of 21 carbapenem resistant P. aeruginosa strains harbored class 1 integron containing aminoglycoside resistance determinant. All of the integrons detected in the study contained more than one resistance gene cassette, which can mediate resistance to multiple antibiotics. To prevent further spreading of the multi-drug resistant P. aeruginosa, conseguent monitoring and clinical polices are required.

  • PDF

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

Characteristics of Heart Rate Variability Derived from ECG during the Driver's Wake and Sleep States (운전자 졸음 및 각성 상태 시 ECG신호 처리를 통한 심장박동 신호 특성)

  • Kim, Min Soo;Kim, Yoon Nyun;Heo, Yun Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.136-142
    • /
    • 2014
  • Distinct features in heart rate signals during the driver's wake and sleep states could provide an initiative for the development of a safe driving systems such as drowsiness detecting sensor in a smart wheel. We measured ECG from health subjects ($23.5{\pm}2.5$ in age) during the wake and drowsiness states. The proposed method is able to detect R waves and R-R interval calculation in the ECG even when the signal includes in abnormal signals. Heart rate variability(HRV) was investigated for the time domain and frequency domains. The STD HR(0.029), NN50(0.044) and VLF power(0.0018) of the RR interval series of the subjects were significantly different from those of the control group (p < 0.05). In conclusion, there are changes in heart rate from wake to drowsiness that are potentially to be detected. The results in our study could be useful for the development of drowsiness detection sensors for effective real-time monitoring.