• Title/Summary/Keyword: Biomedical Monitoring

Search Result 455, Processing Time 0.028 seconds

A Study on the Cognizance of Hospital and oriental Hospital Workers for Medical Device Safety Information Monitoring (의료기기 안전성 정보 모니터링에 대한 한병병원 및 병원 종사자의 인지도 조사연구)

  • Kim, Ji Hyun;Nam, Ki Chang;Kim, Hojun;Nam, Yeon Gyo;Kim, You Jin;jo, Eun hye;Kwon, Bum Sun
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.86-93
    • /
    • 2021
  • Purpose: The purpose of this study is to find out the cognizance of medical device safety information (MDSI) monitoring in the hospital and oriental hospital workers, and the different aspect of MDSI between oriental medical devices and medical devices. Methods: The survey was performed both in the oriental medicine hospital and general hospital. The survey had 16 items; 2 items basic questions, 5 items in the awareness of MDSI, 5 items in the education of MDSI, 4 items in the necessity of defining oriental medical devices and differences between general and oriental medical devices. A total of 120 hospital worker were participated; 60 oriental medicine hospital workers and 60 general hospital workers. They had worked in the oriental medicine or general hospital associated with 'Medical Device Safety Monitoring Center, Dongguk University Ilsan Hospital' in 2019 and 2020. Results: The cognizance of MDSI was high both in oriental medicine hospital and general hospital workers and there were no significant differences between oriental medicine and general hospital workers. When we divided the hospital workers into the senior workers who had worked for over 3 years and junior workers for less than 3 years, the senior workers had higher awareness of MDSI than junior workers. However, the cognizance of education of MDSI was high which was not different between senior and junior workers. Both hospital workers thought that it was necessary to define oriental medicine device legally and the oriental medical device might have low risk and less side effect than medical device. Conclusion: The cognizance of MDSI was high and there was no significant differences between oriental medicine and general hospital workers. Because the senior hospital workers had higher recognition of MDSI, we need to provide the continuous education program for junior hospital workers. Although oriental medical device are thought to be safer than medical device, we need to have a legal definition.

Outcomes of Carotid Endarterectomy according to the Anesthetic Method: General versus Regional Anesthesia

  • Kim, Jong Won;Huh, Up;Song, Seunghwan;Sung, Sang Min;Hong, Jung Min;Cho, Areum
    • Journal of Chest Surgery
    • /
    • v.52 no.6
    • /
    • pp.392-399
    • /
    • 2019
  • Background: The surgical strategies for carotid endarterectomy (CEA) vary in terms of the anesthesia method, neurological monitoring, shunt usage, and closure technique, and no gold-standard procedure has been established yet. We aimed to analyze the feasibility and benefits of CEA under regional anesthesia (RA) and CEA under general anesthesia (GA). Methods: Between June 2012 and December 2017, 65 patients who had undergone CEA were enrolled, and their medical records were prospectively collected and retrospectively reviewed. A total of 35 patients underwent CEA under RA with cervical plexus block, whereas 30 patients underwent CEA under GA. In the RA group, a carotid shunt was selectively used for patients who exhibited negative results on the awake test. In contrast, such a shunt was used for all patients in the GA group. Results: There were no cases of postoperative stroke, cardiovascular events, or mortality. Nerve injuries were noted in 4 patients (3 in the RA group and 1 in the GA group), but they fully recovered prior to discharge. Operative time and clamp time were shorter in the RA group than in the GA group (119.29±27.71 min vs. 161.43±20.79 min, p<0.001; 30.57±6.80 min vs. 51.77±13.38 min, p<0.001, respectively). The hospital stay was shorter in the RA group than in the GA group (14.6±5.05 days vs. 18.97±8.92 days, p=0.022). None of the patients experienced a stroke or restenosis during the 27.23±20.3-month follow-up period. Conclusion: RA with a reliable awake test reduces shunt use and decreases the clamp and operative times of CEA, eventually resulting in a reduced length of hospital stay.

Comparison of Optimal Storage Temperature and Collection Reagents for Living Bacterial Cells in Swab Samples (면봉시료에서 세균의 보존을 위한 최적 보관 온도와 채취 시약의 비교)

  • Lee, Yeong Ju;You, Hee Sang;Lee, Song Hee;Lee, So Lip;Lee, Han;Sung, Ho Joong;Kang, Hee Gyoo;Hyun, Sung Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.4
    • /
    • pp.326-332
    • /
    • 2021
  • Swabs are useful and common sampling tools in various research fields, such as medicine, ecology, biotechnology, forensic medicine, and pollutant monitoring systems. Collection reagents are one of the essential components in sampling. It is important to develop a sample collection kit and designate an appropriate storage temperature because samples need to be stored for a long time. The purpose of this study was to identify the effects of three collection reagents and three storage temperatures on the recovery of living bacteria without media. We selected Escherichia coli and Staphylococcus aureus as representative environmental bacteria. Distilled water (DW), phosphate buffered saline (PBS), and Tris-EDTA (TE) buffer were used as collection reagents and stored at 22℃, 4℃, and -70℃ after sampling. The results of using each collection reagent and storage temperature on the bacteria were compared using relative light units (RLU) and the number of colony forming units (CFU). When using -70℃ storage temperature and the TE buffer, the number of living bacteria and the RLU values remained constant. It is therefore recommended that the sample be stored at -70℃ immediately after collection and a TE buffer solution be used as the collection reagent.

Elevation of Procalcitonin in an Adolescent Acetaminophen Intoxication (아세트아미노펜 중독 청소년에서의 프로칼시토닌 상승)

  • Kim, So Eun;Lee, Jae Baek;Jin, Young Ho;Yoon, Jae Chol;Jo, Si On;Jeong, Tae Oh
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.1
    • /
    • pp.38-41
    • /
    • 2019
  • Procalcitonin (PCT) is commonly employed in medical practice as a diagnostic biomarker of bacterial infection and also as a monitoring biomarker for antimicrobial therapy. There have been a few published reports concerning elevated PCT levels in people with acute liver injury caused by an overdose of acetaminophen. We report here on a case of PCT elevation in an adolescent with acute acetaminophen poisoning without any bacterial infection or liver injury. A 15-year-old girl had deliberately ingested 20 tablets of 650 mg acetaminophen (13 g) and she presented to our emergency department. The PCT level on admission was elevated to 65.64 ng/mL (reference range: 0-0.5 ng/mL). Her PCT level on the second day peaked up to 100 ng/mL and then it gradually decreased. There was no evidence of liver injury or infection on the computed tomography examination and other lab tests. The patient regained her good health and was discharged on the sixth day of hospitalization.

A Study of Electrode Locations for Design of ECG Monitoring Smart Clothing based on Body Mapping (심전도 모니터링 스마트 의류 디자인을 위한 바디매핑 기반 전극 위치 연구)

  • Cho, Hakyung;Cho, Sang woo
    • Fashion & Textile Research Journal
    • /
    • v.17 no.6
    • /
    • pp.1039-1049
    • /
    • 2015
  • The increase in the need for a 24 hour monitoring of biological signals has been accompanied by an increasing interest in wearable systems that can register ECG at any time and place. ECG-monitoring clothing is a wearable system that records heart function continuously, but there have been difficulties in making accurate measurements due to motion artifacts. Although various factors may cause noise in measurements due to motion, the variations in the body surface and clothing during movements that cause eventual the shifting and displacement of the electrodes is particularly noteworthy. Therefore, this study used biomedical body mapping and a motion-capture system to measure and analyze the changes in the body surface and garment during movements. It was deduced that the area where the friction and separation between the garment and skin is the lowest would be the appropriate location to place the ECG electrodes. For this study, 5 male and 5 female in their 20s were selected as subjects, and through their selected body movements, the changes in the garment and skin were analyzed using the motion-capture system. As a result, the area below the chest circumference and the area below the shoulder blades were proposed as the optimal location of electrode for ECG monitoring.

U-Healthcare Patch Type Wireless Body Temperature Monitoring System (유헬스케어 패치형 무선 체온 모니터링 시스템 구현)

  • Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.

The Comparisons between RIA and CIA in CA19-9 Monitoring for Diagnosis of Pancreaticobiliary Tumors

  • Jung, Ha-Seung;Kim, Dae-Sik
    • Biomedical Science Letters
    • /
    • v.15 no.2
    • /
    • pp.135-139
    • /
    • 2009
  • The CA(carbohydrate antigen)19-9 is complex protein that can be used as an important marker which aids the clinical diagnosis and prognosis of various pancreaticobiliary tumors. However, it was also reported that there were some CA19-9 positive patients with benign disease as using RIA method. The purpose of this study is to evaluate the clinical usefulness of serum level of CA19-9 with RIA(radioimmuno assay), CIA(chemiluminescence immuno assay), and conventional liver function tests. The correlation between CIA and RIA in CA19-9 of pancreatobiliary disease was 0.9833(P<0.01). Also, the correlations between CIA and RIA in CA19-9 of benign and malignant pancreaticobiliary tumor patients was 0.8714(P<0.01) and 0.9727(P<0.01) respectively. The correlation between CA19-9 and ALP was 0.5140(P<0.01) and CEA was 0.3385(P<0.05) as using CIA. The measurement of serum CA19-9 levels by CIA method may be useful in differentiating patients with malignant disease from those with benign disease in pancreaticobiliary tumors.

  • PDF

An Implementation of ARM 920T Processor-based Ultrasonic Spirometer and Improvement of Its Sensitivity (ARM 920T 프로세서 기반의 초음파 폐활량계 구현 및 감도 향상 연구)

  • Lee, Cheul-Won;Kim, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.268-273
    • /
    • 2005
  • The spirometer is a medical device that measures the instantaneous velocity of the respiratory gas flow capacity. It is used for testing the condition of the lung and patient monitoring. It measures the absolute capacity difference that includes the flow capacity signal. In this paper, by using an ultrasound sensor that reduce+ the error caused by the inertia and pressure it has improved the transmission and receiving signal. This has enabled patients with weak respiratory to use the spirometer. Also, by using the ARM 920T Processor, a precise and prompt detection system was implemented.

Automatic Detection of Slow-Wave Sleep Based on Electrocardiogram (심전도를 이용한 서파 수면 자동 검출 알고리즘 개발)

  • Yoon, Hee Nam;Hwang, Su Hwan;Jung, Da Woon;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.211-218
    • /
    • 2014
  • The objective of this research is to develop an automatic algorithm based on electrocardiogram (ECG) to estimate slow-wave sleep (SWS). An algorithm is based on 7 indices extracted from heart rate on ECG which simultaneously recorded with standard full night polysomnography from 31 subjects. Those 7 indices were then applied to independent component analysis to extract a feature that discriminates SWS and other sleep stages. Overall Cohen's kappa, accuracy, sensitivity and specificity of the algorithm to detect 30s epochs of SWS were 0.52, 0.87, 0.70 and 0.90, respectively. The automatic SWS detection algorithm could be useful combining with existing REM and wake estimation technique on unattended home-based sleep monitoring.

Optical Spectroscopic Analysis of Muscle Spasticity for Low-Level Laser Therapy (LLLT)

  • Lee, Yeon-Ui;Lee, Sang-Kwan;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2011
  • Current therapeutic methods for suppressing muscle spasticity are intensive functional training, surgery, or pharmacological interventions. However, these methods have not been fully supported by confirmed efficacy due to the aggravation of the muscle spasticity in some patients. In this study, a combined system was developed to treat with a low-level laser and to monitor the region of the treatment using an optical spectroscopic probe that measures oxygen saturation and deoxygenation during low-level laser therapy (LLLT). The evaluation of the wavelength dependence for LLLT was performed using a Monte Carlo simulation and the results showed that the greatest amount of heat generation was seen in the deep tissue at ${\lambda}$ = 830 nm. In the oxy- and deoxygenation measurements during and after the treatment, oxygen-Hb concentration was significantly increased in the laser-irradiated group when compared to the control group. These findings suggest that LLLT using ${\lambda}$ = 830 nm may be of benefit in accelerating recovery of muscle spasticity. The combined system that we have developed can monitor the physiological condition of muscle spasticity during the laser treatment in real time and may also be applied to various myotonia conditions such as muscle fatigue, back-pain treatment/monitoring, and ulcer due to paralysis.