• 제목/요약/키워드: Biomedical Monitoring

검색결과 455건 처리시간 0.025초

Global Healthcare Information System

  • Singh, Dhananjay;Lee, Hoon-Jae;Chung, Wan-Young
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.365-368
    • /
    • 2008
  • This paper presents a new concept of IP-based wireless sensor networks and also introduces a routing protocol that is based on clustering for global healthcare information system. Low-power wireless personal area networks (LoWPANs) conform the standard by IEEE 802.15.4-2003 to IPv6 that makes 6lowpan. It characterized by low bit rate, low power, and low cost as well as protocol for wireless connections. The 6lowpan node with biomedical sensor devices fixed on the patient body area network that should be connected to the gateway in personal area network. Each 6lowpan nodes have IP-addresses that would be directly connected to the internet. With the help of IP-address service provider can recognize or analysis patient biomedical data from anywhere on globe by internet service provider equipments such as cell phone, PDA, note book. The system has been evaluated by technical verification, clinical test, user survey and current status of patient. We used NS-2.33 simulator for our prototype and also simulate the routing protocols. The result shows the performance of biomedical data packets in multi-hope routing as well as represents the topology of the networks.

  • PDF

저출력 레이저의 치료 효과 규명을 위한 근전도 신호의 피로도 해석 연구 (Muscle Fatigue Analysis Based on Electromyography Signals for The Evaluation of Low-Level Laser Therapy)

  • 김지현;최효훈;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권4호
    • /
    • pp.319-327
    • /
    • 2011
  • Skeletal muscle fatigue is defined as a 'any reduction in the maximal capacity to generate force or power output', and is the reduction of oxygen consumption and by-product of metabolism. For the muscle fatigue therapy, low level laser has been introduced that leads the mitochondrial respiratory and attributes the muscle fatigue recovery. This study analyzed the muscle fatigue signals from electromyography(EMG) during low-level laser therapy (LLLT). Healthy subjects performed voluntary elbow flexion-extension excercise and received placebo LLLT and active LLLT using a 830 nm laser diode. Then, EMG were measured for the evaluation of muscle fatigue. The acquired EMG data were analyzed with median frequency and short time fourier transform methods. The results showed that the LLLT had a significant symptomatic relief of muscle fatigue based on the EMG frequency analysis. Therefore, the muscle fatigue analysis with EMG signals can be applied to quantitative evaluation for the monitoring of LLLT effects.

투과광을 이용한 인공심장용 무선정보전달 장치의 개발 (Development of a Transcutaneous Information Transmission System using Transmitted Light for the Total Artificial Heart)

  • 강동우;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.129-131
    • /
    • 1993
  • A transcutaneoos information transmission system using transmitted infrared light for an implantable total artificial heart(TAH) an developed and the performance of the system was tested. In an in vitro test, transmittance of the developed system was measured through various thicknesses of pig shins. In an in vivo test, a loopback test using a personal computer was performed to determine the error rate and an experiment using a mock system was taken. In this experiment, within acceptable lateral and vertical displacements, the error rate of at least 3.8E-6 was guaranteed. Monitoring signals from the internal controller(Intel 87C196) of the mock system were successfully transmitted to the external controller(IBM PC) and the operating commands from the external controller were successfully conducted by the mock system. Communication was done in half duplex mode according to RS-232 protocol at the speed of 4800 bps.

  • PDF

적응 디지털 필터 기반의 MRI Cardiac Gating을 위한 심전도 신호의 MR Gradient 잡음 최소화 방법 (Minimizing MR Gradient Artefacts on ECG Signals for Cardiac Gating based on an Adaptive Digital Filter)

  • 박호동;장봉렬;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.817-818
    • /
    • 2006
  • In Magnetic Resonance Imaging(MRI), the QRS complex of ECG is used as a trigger signal for MRI scan. But, gradient and RF(radio frequency) artifacts which are caused to static and dynamic field in MRI scanner cause interference in the ECG. Also, the signal shape of theses artifacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false gating of the MRI. In case of using general FIR or IIR band-pass filters for minimizing the artifacts, artifact-reduction-ratio is not excellent. So, an adaptive real-time digital filter is proposed for reduction of noise by gradient and RF(radio frequency) artifacts. The proposed filter for MRI-Gating is based on the noise-canceller with NLMS(Normalized Least Mean Square) algorithm. The reference signals of the adaptive noise canceller are a combination of the noisy three channel ECG signals. In conclusions, the proposed method showed the acceptable quality of ECG signal with sufficient SNR for gating the MRI and possibility of real time implementation.

  • PDF

Effects of C10- and C12-chain length alkyl analogs of monochamol on attraction of longhorn pine sawyer Monochamus saltuarius (Coleoptera: Cerambycidae)

  • LEE, Sung-Min;HONG, Do Kyung;JANG, Sei-Heon;LEE, Kyeong-Yeoll;LEE, ChangWoo
    • Entomological Research
    • /
    • 제48권5호
    • /
    • pp.448-452
    • /
    • 2018
  • The aggregation pheromone of Monochamus (Coleoptera: Cerambycidae) beetles, 2-(undecyloxy) ethanol (hereafter referred to as monochamol), has gained considerable attention because of its usefulness in monitoring and population control of pine sawyer beetles. The hydroxyether structural motif is conserved in pheromones of the subfamily Lamiinae of the Cerambycidae. In this study, we investigated the effects of C10- and C12-chain length alkyl analogs of monochamol, 2-(decyloxy) ethanol and 2-(dodecyloxy) ethanol, on attracting M. saltuairus in Andong, Gyeongsangbuk-do, Korea. The C10 and C12 analogs attracted M. saltuarius when used in combination with ${\alpha}$-pinene and ethanol, but the responses of these alkyl chain analogs were lower than those of monochamol. Furthermore, the addition of either C10 or C12 analog to the use of monochamol with ${\alpha}$-pinene and ethanol had no effect on attraction of M. saltuarius, indicating high sensitivity of M. saltuarius to monochanol. Taken together, the results of this study suggest that chemical communication within a Monochamus species depends not only on monochamol, but also on other semiochemicals.

긴급환자 상황인식 및 분석을 위한 무선 ECG모니터링 시스템 (A Wireless ECG monitoring System for Application in Life Emergency Event Detection and Analysis)

  • ;이대석;정완영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.421-425
    • /
    • 2006
  • 헬스케어와 무선 기술의 접목은 새로운 생체신호 모니터링 방법과 환자의 이동성 및 편의성을 제공하며 더 나은 방법으로 환자를 돌볼 수 있으며 이러한 장점으로 인해 최근 무선기술을 이용한 ECG 모니터링 및 계측 시스템이 개발되고 있다. 본 논문에서는 중요한 생체신호 중 가장 중요한 신호의 하나인 ECG 신호를 무선센서네트워크를 이용하여 무선으로 받은 후, 이를 서버컴퓨터에서 의사, 간호사 또는 환자의 보호자에게 진단의 기초자료로 제공할 수 있게 빈맥, 서맥, 동정지와 같은 비정상적인 ECG신호를 판단하는 ECG 모니터링 시스템을 구현하였다. 신체에서 계측된 ECG신호는 무선으로 서버와 RS-232로 연결된 베이스스테이션으로 전송되고 서버는 비정상적인 ECG 신호를 검사하여 저장 및 모니터링을 위해 PC/PDA로 데이터를 전송하며, 이러한 시스템을 활용하여 의료비 절감 및 더 편리한 의료서비스를 받을 수 있을 것으로 예상된다.

  • PDF

Artifical Neural Network for In-Vitro Thrombosis Detection of Mechanical Valve

  • Lee, Hyuk-Soo;Lee, Sang-Hoon
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 The Third Asian Fuzzy Systems Symposium
    • /
    • pp.762-766
    • /
    • 1998
  • Mechanical valve is one of the most widely used implantable artificial organs, Since its failure (mechanical failures and thrombosis to name two representative example) means the death of patient, its reliability is very important and early noninvasive detection is essential requirement . This paper will explain the method to detect the thrombosis formation by spectral analysis and neural network. In order quantitatively to distinguish peak of a normal valve from that of a thrombotic valve, a 3 layer backpropagation neural network, which contains 7,000 input nodes, 20 hidden layer and 1output , was employed. The trained neural network can distinguish normal and thrombotic valve with a probability that is higher than 90% . In conclusion, the acoustical spectrum analysis coupled with a neural network algorithm lent itself to the noninvasive monitoring of implanted mechanical valves. This method will be applied to be applied to the performance evaluation of other implantable rtificial organs.

  • PDF

Detection of Salmonella typhi by Loop-mediated Isothermal Amplification Assay

  • 조윤경
    • 대한의생명과학회지
    • /
    • 제14권2호
    • /
    • pp.115-118
    • /
    • 2008
  • Salmonella typhi is frequent causes of foodborne illness and its detection is important for monitoring disease progression. In this study, by using general PCR and novel LAMP (Loop Mediated Isothermal Amplification) assay, we evaluated the usefulness of LAMP assay for detection of Salmonella typhi. In this LAMP assay, forward inner primer (FIP) and back inner primer (BIP) was specially designed for recognizing target invA gene. Target DNA was amplified and visualized as ladder-like pattern of bands on agarose gel within 60 min under isothermal conditions at $65^{\circ}C$. When the sensitivity and reproducibility of LAMP were compared to general PCR, there was no difference of reproducibility but sensitivity of LAMP assay was more efficient than PCR (the detection limit of LAMP assay was 30 fg, while the PCR assay was 3 pg). These results indicate that the LAMP assay is a potential and valuable means for detection of Salmonella typhi, especially for its rapidity, simplicity and low cost.

  • PDF

응급 원격 진료 시스템을 위한 모바일 장치에서의 실시간 비디오 모니터링 시스템 구현 (Realtime Video Monitoring System for Emergency Telemedicine System In Mobile Device)

  • 김상용;김정채;유선국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.491-492
    • /
    • 2008
  • 무선통신 기술과 모바일 장비의 발전에 따라 의사는 언제, 어디서나 환자의 상태를 실시간으로 모니터링 할 수 있게 되었다. 이 연구에서는 원격지 PC에서 인코딩한 환자의 비디오 영상을 무선통신으로 전송한다.[1] 이때, 모바일 장비(PDA)는 PC에서 보낸 비디오 영상을 전송 받고, 디코딩하여 화면에 출력한다. 이번 논문에서 개발한 시스템은 후자에 기술된 모바일 실시간 비디오 모니터링 시스템이다. 개발에 사용된 비디오 코덱은 MPEG-4 계열의 오픈소스 코덱인 Xvid이다. 데스탑 PC용 Xvid 오픈소스를 모바일 디바이스에서 사용할 수 있도록 컨버전하여 사용하였다. 무선 통신망은 WiBro를 사용하여 고화질 비디오를 전송받을 수 있는 대역폭을 확보였다. 이 논문 목적은 의사가 PC앞에 앉아 있지 않아도 이동간에 환자의 현재 상태를 실시간으로 확인할 수 있음으로서 의사의 작업효율을 증진시키는데 있다.

  • PDF

가열과 운동에 의한 생체조직내의 생리적 변화에 따른 광학적 특성의 변화에 관한 연구 (The Effects of Physiological Heating and Exercise on the Optical Properties of Biological Tissue.)

  • 임현수;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.81-88
    • /
    • 1993
  • This paper is the study of the reflectance of light from biological tissue for red and Infrared wavelengths and relates the acquired reflectance data to expected physiological changes within the skin and muscle layers associated with heat and exercise. The instrument was disigned to collect data from the calf muscle in human subjects with probe located at the surface of skin. Rapid data acquisition method allowed monitoring of rapid changes in reflecttance due to a stimulus. This study demonstrates that changes in O2 saturation and blood fractional volume expected within the dermis and muscle layers were asserted by examining the slopes of the plotted index for heat and exercise. The results presented in thls study support the claim that reflectance can separately discriminate between changes of blood volume and oxygenation in muscle and in skin. The data demonstrate the ability to measure consistent changes In tissue optical properties during exercise and heat.

  • PDF