• Title/Summary/Keyword: Biomedical Information

Search Result 1,680, Processing Time 0.037 seconds

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

Association Analysis between Chromogranin B Genetic Variations and Smooth Pursuit Eye Movement Abnormality in Korean Patients with Schizophrenia (한국인 조현병 환자에서 Chromogranin B 유전자와 안구운동 이상의 연합에 대한 연구)

  • Park, Jin Wan;Pak, Doo Hyun;Hwang, Min Gyu;Lee, Min Ji;Shin, Hyoung Doo;Shin, Tae-Min;Hahn, Sang Woo;Hwang, Jaeuk;Lee, Yeon Jung;Woo, Sung-Il
    • Korean Journal of Biological Psychiatry
    • /
    • v.25 no.4
    • /
    • pp.101-109
    • /
    • 2018
  • Objectives According to previous studies, the Chromogranin B (CHGB) gene could be an important candidate gene for schizophrenia which is located on chromosome 20p12.3. Some studies have linked the polymorphism in CHGB gene with the risk of schizophrenia. Meanwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. Methods We measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. Results The natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). Conclusions Despite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.nwhile, smooth pursuit eye movement (SPEM) abnormality has been regarded as one of the most consistent endophenotype of schizophrenia. In this study, we investigated the association between the polymorphisms in CHGB gene and SPEM abnormality in Korean patients with schizophrenia. MethodsZZWe measured SPEM function in 24 Korean patients with schizophrenia (16 male, 8 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated genotypes of polymorphisms in CHGB gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of polymorphism. ResultsZZThe natural logarithm value of signal/noise ratio (Ln S/N ratio) of good SPEM function group was $4.19{\pm}0.19$ and that of poor SPEM function group was $3.17{\pm}0.65$. In total, 15 single nucleotide polymorphisms of CHGB were identified and the genotypes were divided into C/C, C/R, and R/R. Statistical analysis revealed that two genetic variants (rs16991480, rs76791154) were associated with SPEM abnormality in schizophrenia (p = 0.004). ConclusionsZZDespite the limitations including a small number of samples and lack of functional study, our results suggest that genetic variants of CHGB may be associated with SPEM abnormality and provide useful preliminary information for further study.

  • PDF

Investigation of Domestic and Foreign Unexpected Antibodies for Emergency Blood Transfusion (응급수혈을 위한 비예기 항체의 국내·외 실태조사)

  • Weonjoo, Hwang;Sang-Hee, Lee;Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.279-284
    • /
    • 2022
  • Certain pre-transfusion tests are not commonly performed during emergency blood transfusion. In this study, we reviewed and analyzed the data of post-blood transfusion antibody screening tests to establish the effects of unexpected antibodies causing hemolytic transfusion reactions. We reviewed information published domestically and internationally, and selected the data of 68,602 antibody screening tests and 528 antibody identification tests conducted at P hospital. We found that unexpected antibody positive (1198,1.74%), Rh type (161, 30.49%), Lewis type (67, 12.69%), others (Di (a), 28, 5.30%). The anti-E type positive was 93 (17.61%), and that of the cases with anti-C (13, 2.46%). Only data of domestic cases were included for analysis that were published before 2007, which established the presence of antibodies of the following types and numbers of cases: anti-E (196, 22.45%), anti-Le a (82, 9.39%), and anti-E+C (60, 6.87%). In 2018, anti-E (107, 17.12%), anti-E+Canti-E+C (56, 8.96%), and anti-Di a (28, 4.48%) were detected. In other domestic cases, S hospital was detect to anti-E, anti-Le a, anti-E+C. The Anti-E, anti-D, anti-E+C, and anti-C+E were detected in D hospital. In Saudi Arabia, Anti-D, anti-E, and anti-Jka was detected. The Anti-M, Anti-N, Anti-Le (a), and Anti-D were detected in India. Requests for emergency blood transfusion increased 1.8 times after the opening of the trauma center. This study has the disadvantage of being a cross-sectional study. additional studies are needed to provide basic information on alternative treatments that can increase the safety and reduce the side effects of hemolytic transfusion in emergency transfusion situations.

Comparison of Results between Cytogenetic Technique and Molecular Genetic Technique in Colorectal Carcinoma Patients (대장암환자의 염색체 결실에서 세포유전학적 기법과 분자유전학적 기법의 결과 비교)

  • Park, Cheolin;Lee, Jae Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.285-293
    • /
    • 2017
  • Globally, 1.3 million people develop colon cancer every year, and 600,000 people die each year it. In Korea, colorectal carcinoma was associated with the highest death rate, accounting for 8,380 people, among solid cancers in 2015. Among the various methods for the diagnosis and study of colorectal carcinoma, the results obtained by cytogenetic and molecular genetic methods were compared. Detection rate was 47% in 18q, 40% in 17p, 27% in 22q, and 17% in 10q via CGH; detection rate was 57% in D18S59, 50% in D18S68, 50% in TP53CA, 47% in D18S6940% in D22S274, 37% in D22S283, 27% in D10S187, and 23% in D10S541 with LOH. Microsatellite marker matching rates were 100% in D22S274, 100% in D22S283, 100% in D10S186, 100% in D10S187, 100% in D10S541, 93% in D18S69, 93% in D18S68, 92% in TP53CA, and 89% in D18S59. The agreement rate between the two methods was 94.4% based on positive results using CGH. Based on the advantages of CGH, which was the ability to obtain information regarding the entire tumor genome at once, this experiment could identify the region with significant deletion using CGH and the more limited region LOH, with a completely different approach. LOH in the recurrent high-risk group, 18q21, was helpful in the selection of treatment modalities and in prognostic estimation as well as making the most appropriate decision for treatment. Therefore, it is suggested that LOH with surgical site tissues could be one of the treatment methods for recurrent high-risk group among patients with colorectal carcinoma.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

The Correlation Between Sensory Integration Function and Scholar Achievement in the Lower Classes Children (저학령기 아동의 감각통합 기능과 학업성취도간의 상관관계)

  • Shin, Joong-Il;Choi, Yung-Gun;Jang, Woo-Heuk;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Objective : The purpose of this study is to provide reference to functional level of sensory integration of in the low-grads school age, based on the Clinical Observation of Motor and Postural Skills (COMPS) and to examine correlation between the function of sensory integration and academic achievement. Method : Two schools ("J" and "S") have been selected indiscriminately among 56 elementary schools located in Gimhae-si, GyeongNam and then one class from each school was voluntarily chosen among all second-grade classes of the schools. The total number of students in those two classes was 69 (34 boys and 35 girls). Subjects had no developmental problem and no history of referral regarding neurological conditions. Three skilled researchers administrated the COMPS together, and each researcher executed two sub-items of the COMPS. As result of the academic achievement, score data of midterm- and final-exam in the spring semester were collected. The scores of 'Korean language' and 'Math', common examination subjects in both schools, were utilized for data analysis in this study. Results : Statically, there was no significant correlation between the COMPS Weighted Scores and any academic achievements. In a dispersion graphic analysis, however, the total achievement showed significant negative-correlation with the area of 'Rapid Forearm Rotation' and significant positive-correlation with the area of 'Supine Flexion'. In terms of the Math achievement, there are significant negative-correlation with rapid forearm rotation and asymmetrical tonic neck reflex, and significant positive-correlation with the area of 'Supine Flexion'. Students with higher score of the Korean language showed a tendency to get higher Weighted Score and Minus Adjustment Score, and those with lower score of the Math showed a tendency to get higher COMPS scores in all area except the area of 'Supine Flexion'. There was a statically significant difference in the COMPS scores depend on the age among general characteristics. As student older, all COMPS scores, except those in the area of 'Slow Motion' and 'Supine Flexion, were higher. Conclusions : There is somehow reliable correlation between sensory integration function and academic achievement although no statistical significance found in this study. The information from this study may contribute to initiate developing a normative-reference to screen earlier and more alertly sensory integration dysfunctions for school-age children. Further study is recommended trying to find out more reliable matter regarding low grade- schooler's academic achievement.

  • PDF

Proteomic Assessment of the Relevant Factors Affecting Pork Meat Quality Associated with Longissimus dorsi Muscles in Duroc Pigs

  • Cho, Jin Hyoung;Lee, Ra Ham;Jeon, Young-Joo;Park, Seon-Min;Shin, Jae-Cheon;Kim, Seok-Ho;Jeong, Jin Young;Kang, Hyun-sung;Choi, Nag-Jin;Seo, Kang Seok;Cho, Young Sik;Kim, MinSeok S.;Ko, Sungho;Seo, Jae-Min;Lee, Seung-Youp;Shim, Jung-Hyun;Chae, Jung-Il
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.11
    • /
    • pp.1653-1663
    • /
    • 2016
  • Meat quality is a complex trait influenced by many factors, including genetics, nutrition, feeding environment, animal handling, and their interactions. To elucidate relevant factors affecting pork quality associated with oxidative stress and muscle development, we analyzed protein expression in high quality longissimus dorsi muscles (HQLD) and low quality longissimus dorsi muscles (LQLD) from Duroc pigs by liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analysis. Between HQLD (n = 20) and LQLD (n = 20) Duroc pigs, 24 differentially expressed proteins were identified by LC-MS/MS. A total of 10 and 14 proteins were highly expressed in HQLD and LQLD, respectively. The 24 proteins have putative functions in the following seven categories: catalytic activity (31%), ATPase activity (19%), oxidoreductase activity (13%), cytoskeletal protein binding (13%), actin binding (12%), calcium ion binding (6%), and structural constituent of muscle (6%). Silver-stained image analysis revealed significant differential expression of lactate dehydrogenase A (LDHA) between HQLD and LQLD Duroc pigs. LDHA was subjected to in vitro study of myogenesis under oxidative stress conditions and LDH activity assay to verification its role in oxidative stress. No significant difference of mRNA expression level of LDHA was found between normal and oxidative stress condition. However, LDH activity was significantly higher under oxidative stress condition than at normal condition using in vitro model of myogenesis. The highly expressed LDHA was positively correlated with LQLD. Moreover, LDHA activity increased by oxidative stress was reduced by antioxidant resveratrol. This paper emphasizes the importance of differential expression patterns of proteins and their interaction for the development of meat quality traits. Our proteome data provides valuable information on important factors which might aid in the regulation of muscle development and the improvement of meat quality in longissimus dorsi muscles of Duroc pigs under oxidative stress conditions.

Voxel-based Investigations of Phase Mask Effects on Susceptibility Weighted Images (화소 간 분석을 이용하여 자화율 가중 영상(SWI)에 나타난 위상 마스킹의 효과 분석)

  • Hwang, Eo-Jin;Kim, Min-Ji;Kim, Hyug-Gi;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.25-34
    • /
    • 2013
  • To investigate effects of phase mask on susceptibility-weighted images (SWI) using voxel-based analyses in normal elderly subjects. A three-dimensional (3D) gradient echo sequence ran to obtain SWIs in 20 healthy elderly subjects. SWIs with two (SWI2) and four (SWI4) phase multiplications were achieved with positive (PSWI) and negative (NSWI) phase masks to investigate phase mask effects. The voxel-based comparisons were performed using paired t-tests between PSWI and NSWI and between SWI2 and SWI4. Differences of signal intensities between magnitude images and SWI4 were larger than those between magnitude images and SWI2s. Differences of signal intensities between magnitude images and PSWIs were larger than those between magnitude images and NSWIs. Moreover, the signal intensities from NSWI2s and NSWI4s were greater than those from PSWI2s and PSWI4s, respectively. More differences of signal intensities between NSWI4 and PSWI4s were found than those between NSWI2s and PSWI2s in the whole brain images. The voxel-based analyses of SWI could be beneficial to investigate susceptibility differences on the entire brain areas. The phase masking method could be chosen to enhance brain tissue contrast rather than to enhance venous blood vessels. Therefore, it is recommended to apply voxel-based analyses of SWI to investigate clinical applications.

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF