반사형 소자를 이용한 시료의 컬러정보 및 농도분석 (An Optical Technique for Concentration Measurement by Color Analysis)

  • 이태희;김지선;정구인;최주현;오한별;김아희;정현철;조영빈;전재훈
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1121-1127
    • /
    • 2014
  • Many studies have been done to measure and analyze color for various purposes. Visual assessment has lack of objectivity and the equipment for color measurement is very expensive. In this study, we developed a device for quantitative analysis of the color using optical elements. With the color sensor, the ratio of RGB was calculated by measuring the light intensity that is reflected from an object. Inverse transformation of optical signal was performed to detect the color density. The suggested color analyzer can detect color information as well as sample concentration. Results of this study are expected to be used in various medical fields such as pH indicator and urine analysis.

An Array-Type RGB Sensor for Precision Measurement of pH

  • Kim, Ji-Sun;Oh, Han-Byeol;Kim, A-Hee;Kim, Jun-Sik;Lee, Eun-Suk;Goh, Bong-Jun;Choi, Ju-Hyeon;Shin, Ye-Ji;Baek, Jin-Young;Lee, Ki Sung;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.700-704
    • /
    • 2015
  • As pH is a widely used index in chemical, medical, and environmental applications, research on pH sensors has been active in recent years. This study obtained RGB values by measuring the reflected light from a liquid sample to detect fine changes in pH, and performed mathematical modeling to investigate the relationship between the detected optical signal and pH value. Also, the trends in pH changes were easily identified by analyzing RGB values and displaying them in the color coordinate for easy visualization of data. This method implemented a user-friendly system that can measure and analyze in real time. This system can be used in many fields such as genetic engineering, environmental engineering, and clinical engineering, because it not only can measure pH but also replaces a colorimeter or turbidimeter.

플라스틱 광섬유를 이용한 호흡센서의 개발 (Development of a Respiration Sensor Using Plastic Optical Fiber)

  • 유욱재;백지윤;조동현;장경원;서정기;허지연;이봉수;조영호;박병기;문주현
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.489-494
    • /
    • 2009
  • In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the $BIOPAC^{(R)}$ system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study.

광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정 (Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR)

  • 심혁인;유욱재;신상훈;장재석;김재석;장경원;조승현;문주현;이봉수
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1239-1244
    • /
    • 2014
  • In this study, two fiber-optic sensors were fabricated to measure water level and temperature using optical fibers, a coupler, a Lophine and an OTDR (optical time-domain reflectometer). First, using Fresnel's reflection generated at the distal-ends of each optical fiber, which was installed at different depth, we measured the water level according to the variation of water level. Next, we also measured the temperature of water using a temperature sensing probe based on the Lophine, whose absorbance changes with the temperature. The measurable temperature range of the fiber-optic sensor is from $5^{\circ}C$ to $65^{\circ}C$ because the maximum operation temperature of the optical fiber without a physical deterioration is up to $80^{\circ}C$.

핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석 (Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application)

  • 홍승한;유욱재;신상훈;서정기;한기택;전다영;조승현;이봉수
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

적외선 투과 광섬유를 이용한 고주파 열치료 과정에서의 온도분포 측정 (Measurements of temperature distribution using an infrared optical fiber during radiofrequency ablation)

  • 유욱재;서정기;조동현;장경원;신상훈;이봉수;탁계래;박병기;문주현
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.397-405
    • /
    • 2008
  • In this study, we have measured temperature distribution using infrared optical fibers during radiofrequency ablation (RFA). Infrared radiations generated from the water around inserted electrode are transferred by silver halide optical fibers and are measured by a thermopile sensor. Also, the output voltages of a thermopile sensor are compared with those of the thermocouple recorder. It is expected that a noncontact temperature sensor using an infrared optical fiber can be developed for the temperature monitoring during RFA treatments based on the results of this study.

광섬유 종단각도 효과를 이용한 관절각 측정 (Effect of Modified Fiber Tip on Joint Angle Measurement)

  • 정구인;김지선;이태희;최주현;오한별;김아희;전재훈
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.929-933
    • /
    • 2014
  • The measurement of joint angle is important to evaluate the patient's disability. The modified fiber tip and light propagation of the developed fiber sensor were investigated to increase the range of angle detection. Different shapes of fiber tips were manufactured with a polishing machine to deliver light signal in various patterns. Output signals were analyzed to obtain joint angle change with inverse polynomial models. The measured joint angles were displayed with LabVIEW program and the reliability was tested by comparing with a commercial angle sensor. This method can be used in rehabilitation field to determine patient's progress.

운전 중 돌발 상황과 관련된 인지 처리 및 감정 반응의 피부전도수준 해석 (Analysis of Skin Conductance Level for Cognitional and Emotional Responses associated with Unexpected Situation during Driving)

  • 이수정;양재웅;김지혜;최미현;문경률;김한수;최진승;지두환;민병찬;탁계래;정순철
    • 대한인간공학회지
    • /
    • 제29권6호
    • /
    • pp.869-874
    • /
    • 2010
  • The purpose of this study was to analyze the skin conductance level (SCL) induced by unexpected situation which reflected the emotional and cognitional responses during driving. The participants included 57 college graduates; 28 males aged $24.5{\pm}1.3$ with $2.3{\pm}1.5$ years of driving experiences and 29 females aged $23.6{\pm}2.6$ with $2.2{\pm}1.7$ years of driving experience. Reaction time of brake, averaged SCL, maximum SCL, and rising time to maximum amplitude were measured. They were analysed according to condition (crash, non-crash) and gender (male, female). The reaction time of brake was more faster and averaged SCL was greater during non-crash condition than during crash condition. There were no significant differences between male and female drivers in the reaction time of brake and averaged SCL whether or not it crash. There were no significant differences between crash and non-crash conditions in the maximum SCL and rising time to maximum amplitude, but there were significant differences between male and female in them. These results support the hypothesis that averaged SCL is more related to cognitional response and maximum SCL and rising time to maximum amplitude are more related to emotional responses.