• Title/Summary/Keyword: Biological pacemaker

Search Result 14, Processing Time 0.019 seconds

Anatomy and Physiology in Human Circadian Rhythms (인체 일주기리듬의 해부학 및 생리학)

  • Sohn, Chang-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.1
    • /
    • pp.1-11
    • /
    • 1998
  • Chronobiology is the area of medicine that is, how time-related event shape our daily biologic responses and apply to any aspect of medicine with regard to altering pathophysiology and treatment response. In mammals, there are several evidences that prove suprachiasmatic nuclei(SCN) is the major circadian pacemaker and the circadian rhythm influences so many biological aspects of an living organism such as rest-activity, thermoregulation, reproduction, and endocrine system. In case of human beings, there had been little information of circadian system. That may be due to the experimental, technical difficulties to study but also to the fact that human has the more complex environments that may alter the circadina rhythm like the artificial light, many socio-cultural aspects and so forth. However, several reports of these days indicate human's circadian system is composed of two or more circadian oscillators and SCN is the major circadian oscillator among them like the other mammals. Free-running circadinan period of mankind is about 24 hours rather than about 25 hours, and rest-activity rhythm is polymodal like other species. In addition to that, human may have capcities to change the circadian rhythm as the seasonal changes of daynight schedule. In this article, the author will summarize recent progress of anatomy and physiology of the circadian clock mechanism in humans.

  • PDF

Circadian Rhythms of Melatonin, Thyroid-Stimulating Hormone and Body Temperature: Relationships among those Rhythms and Effect of Sleep-Wake Cycle

  • Kim, Mi-Seung;Lee, Hyun J.;Im, Wook-Bin
    • Animal cells and systems
    • /
    • v.6 no.3
    • /
    • pp.239-245
    • /
    • 2002
  • Plasma melatonin, thyroid-stimulating hormone (TSH) and body temperature were measured simultaneously and continuously before and after the sleep-wake cycle was shifted in 4 healthy males and changes in the circadian rhythm itself and in the phase relationship among these circadian rhythms were determined. Normal sleep-wake cycle (sleep hours: 2300-0700) was delayed by 10 h (sleep hours: 0900-1700) during the experiment. Even after this shift the typical melatonin rhythm was maintained: low during daytime and high during night. The melatonin rhythm was gradually delayed day by day. The TSH rhythm was also maintained fundamentally during 3 consecutive days of altered sleep-wake cycle. The phase was also delayed gradually but remarkably. The daily rhythm of body temperature was changed by the alteration of sleep-wake cycle. The body temperature began to decrease at the similar clock time as in the control but the decline during night awake period was less steep and the lowered body temperature persisted during sleep. The hormonal profiles during the days of shifted sleep/wake cycle suggest that plasma melatonin and TSH rhythms are basically regulated by an endogenous biological clock. The parallel phase shift of melatonin and TSH upon the change in sleep-wake cycle suggests that a common unitary pacemaker probably regulates these two rhythms. The reversal phase relationship between body temperature and melatonin suggests that melatonin may have a hypothermic effect on body temperature. The altered body temperature rhythm suggests that the awake status during night may inhibit the circadian decrease in body temperature and that sleep sustains the lowered body temperature. It is probable but uncertain that there ave causal relationships among sleep, melatonin, TSH, and body temperature.

Detection of Abnormal Heartbeat using Hierarchical Qassification in ECG (계층구조적 분류모델을 이용한 심전도에서의 비정상 비트 검출)

  • Lee, Do-Hoon;Cho, Baek-Hwan;Park, Kwan-Soo;Song, Soo-Hwa;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young;Kim, Sun-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.466-476
    • /
    • 2008
  • The more people use ambulatory electrocardiogram(ECG) for arrhythmia detection, the more researchers report the automatic classification algorithms. Most of the previous studies don't consider the un-balanced data distribution. Even in patients, there are much more normal beats than abnormal beats among the data from 24 hours. To solve this problem, the hierarchical classification using 21 features was adopted for arrhythmia abnormal beat detection. The features include R-R intervals and data to describe the morphology of the wave. To validate the algorithm, 44 non-pacemaker recordings from physionet were used. The hierarchical classification model with 2 stages on domain knowledge was constructed. Using our suggested method, we could improve the performance in abnormal beat classification from the conventional multi-class classification method. In conclusion, the domain knowledge based hierarchical classification is useful to the ECG beat classification with unbalanced data distribution.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF