• 제목/요약/키워드: Biological Nitrogen Treatment

검색결과 350건 처리시간 0.026초

저온 태양열을 이용한 생물학적 오수 처리 장치 실증 실험 (Field Test for a Biological Nitrogen Treatment System with Low Temperature Solar Thermal Energy)

  • 정모;이동원
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.34-41
    • /
    • 2008
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25-30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

저온 태양열 이용 생물학적 오수 처리 (Biological Waste Water Treatment with Solar Thermal Energy)

  • 정모;이동원;김정배;윤응상;변무룡;변무원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.559-562
    • /
    • 2006
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25{\sim}30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

  • PDF

${\cdot}$ 폐수처리장에서의 생물학적 질소제거 프로그램 검증 (Verification of biological nitrogen removal program in sewage or wastewater treatment plants)

  • 김희선;이병대
    • 한국응용과학기술학회지
    • /
    • 제24권4호
    • /
    • pp.332-338
    • /
    • 2007
  • Based on the experiment results of laboratory scale modified anoxic-oxic process for leachate treatment, biological nitrogen removal program was verified in terms of SS, COD, and TN concentration. These measured water qualities concentration could be predicted by biological nitrogen removal program with $R^2$ of 0.994, 0.987, 0.990, respectively. No error was occurred between water qualities concentration and quite wide range of water qualities concentration (i.e., 50-4200 mg/L) during the modelling. Each unit and final effluent of simulated concentration was kept good relationship with that of measured concentration therefore this biological nitrogen removal program for sewage or wastewater treatment plants has good reliance.

Nitrification of low concentration ammonia nitrogen using zeolite biological aerated filter (ZBAF)

  • Kim, Jin-Su;Lee, Ji-Young;Choi, Seung-Kyu;Zhu, Qian;Lee, Sang-Ill
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.554-560
    • /
    • 2020
  • This study focuses on nitrification through a biological aerated filter (BAF) that is filled with a zeolite medium at low concentrations of ammonia. The zeolite medium consists of natural zeolite powder. The BAF is operated under two types of media, which are a ball-type zeolite medium and expanded poly propylene (EPP) medium. Nitrification occurred in the zeolite BAF (ZBAF) when the influent concentration of ammonia nitrogen was 3 mg L-1, but the BAF that was filled with an EPP medium did not experience nitrification. The ammonia nitrogen removal efficiency of ZBAF was 63.38% and the average nitrate nitrogen concentration was 1.746 mg/L. The ZBAF was tested again after a comparison experiment to treat pond water, and municipal wastewater mixed pond water. The ZBAF showed remarkable ammonia-nitrogen treatment at low concentration and low temperature. During this period, the average ammonia nitrogen removal efficiency was 64.56%. Especially, when water temperature decreased to 4.7℃, ammonia nitrogen removal efficiency remained 79%. On the other hand, the chemical-oxygen demand (COD) and phosphorus-removal trends were different. The COD and phosphorus did not show as efficient treatment as the ammonia-nitrogen treatment.

산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용 (Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water)

  • 방성훈;임은태;정귀택;박재희;박석환;김성준;박돈희
    • KSBB Journal
    • /
    • 제23권6호
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.

Application of tube-type ceramic microfiltration membrane for post-treatment of effluent from biological wastewater treatment process using phase separation

  • Son, Dong-Jin;Kim, Woo-Yeol;Yun, Chan-Young;Kim, Dae-Gun;Chang, Duk;Sunwoo, Young;Hong, Ki-Ho
    • Environmental Engineering Research
    • /
    • 제22권4호
    • /
    • pp.377-383
    • /
    • 2017
  • A tube-type ceramic membrane for microfiltration was developed, and the membrane module comprised of three membranes was also applied to biological carbon and nitrogen removal processes for post-treatment. Manufacturing the microfiltration membrane was successful with the structure and boundary of the coated and support layers within the membrane module clearly observable. Total kjeldahl nitrogen removal from effluent was additionally achieved through the elimination of solids containing organic nitrogen by use of the ceramic membrane module. Removal of suspended solids and colloidal substances were noticeably improved after membrane filtration, and the filtration function of the ceramic membrane could also easily be recovered by physical cleaning. By using the ceramic membrane module, the system showed average removals of organics, nitrogen, and solids up to 98%, 80% and 99.9%, respectively. Thus, this microfiltration system appears to be an alternative and flexible option for existing biological nutrient removal processes suffering from poor settling performance due to the use of a clarifier.

Nitrogen removal from wastewaters without carbon sources using microalgae

  • 이광용;이철균
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.553-556
    • /
    • 2000
  • Possibility of biological nitrogen treatment was tested in wastewaters with low C/N ratio. Chlorella kessleri was inoculated at $10^6\;cell/mL$ of initial density in two different artificial wastewaters: one that contained glucose for organic carbon source and the other without carbon source. Nitrate could be successfully reduced below 10 mg $NO_3/mL$ from initial nitrate concentration of 560 mg $NO_3/mL$ in 10 days even in the wastewater without carbon source, This 98% removal of nitrate without extra organic carbon source lights up the future of biological wastewater treatment, where the insufficient ability of nitrogen removal is a major problem.

  • PDF

미세조류를 이용한 질소제거 장치의 크기 (Size Estimation of Microalgal System for Nitrogen Removal)

  • 김한욱;이우성;이철균
    • KSBB Journal
    • /
    • 제19권3호
    • /
    • pp.236-240
    • /
    • 2004
  • Batch experiment에서 다양한 질소 농도에서 구해진 질소제거 속도와 비 생장속도 등의 데이터를 토대로 4.6일의 체류시간을 갖는 2단 처리 장치를 설계하였다. 그리고 continuous experiments에서는 3.5일의 체류시간을 갖는 2단의 처리 장치를 설계하였다. 두 가지 값에 차이는 있지만 실제 현장에서 폐수 처리 장치를 설계할 때 충분한 자료가 되리라고 판단한다. 따라서 위의 결과를 토대로 기존 시스템에 미세조류 시스템을 부가한다면 기존공정의 단점인 잉여질소 제거 장치로서 충분히 역할을 수행해 배출 기준치를 만족시키는 안전한 폐수처리장치가 되리라고 판단한다.

Effects of Nitrogen Fertilizer on Growth of Indigofera pseudo-tinctoria in Kyongseodong Waste Landfill, Incheon

  • Kim, Kee-Dae;Lee, Sang-Mo;Lee, Eun-Ju
    • The Korean Journal of Ecology
    • /
    • 제26권2호
    • /
    • pp.71-74
    • /
    • 2003
  • Effects of nitrogen addition on the growth of Indigofera pseudo-tinctoria (Leguminosae) in the waste landfill site was investigated. Nitrogen fertilization in the nitrogen poor soils of waste landfill may influence the growth of nitrogen fixing plants beneficially or detrimentally. When I. pseudo-tinctoria was fertilized with three different levels of nitrogen, the coverage of plants treated with 46 g N/$m^2$ and 460 g N/$m^2$ was significantly less than that of plants treated with 23 g N/$m^2$. The growth rates of plant height treated with 46 g N/$m^2$ and 460 g N/$m^2$ were significantly less than those of plants treated with 23 g N/$m^2$. The growth rates of plant diameter treated with 46 g N/$m^2$ and 460 g N/$m^2$ were significantly less than those of plants treated with 23 g N/$m^2$. Dry weights of whole plants in control sites were higher than those of all the others nitrogen treatment sites. Nodule numbers were higher in control plants than those of plants in all the other nitrogen treatment sites. It is suggested that nitrogen fertilizer addition over 23 g N/$m^2$ affect the growth of some nitrogen fixing plants, such as I. pseudo-tinctoria, negatively.

Optimization of Atmospheric Cold Plasma Treatment with Different Gases for Reduction of Escherichia coli in Wheat Flour

  • Lee, Jeongmin;Park, Seul-Ki;Korber, Darren;Baik, Oon-Doo
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권6호
    • /
    • pp.768-775
    • /
    • 2022
  • In this study we aimed to derive the response surface models for Escherichia coli reduction in wheat flour using atmospheric cold plasma (ACP) with three types of gas. The jet-type atmospheric cold plasma wand system was used with a 30 W power supply, and three gases (argon, air, and nitrogen) were applied as the treatment gas. The operating parameters for process optimization considered were wheat flour mass (g), treatment time (min), and gas flow rate (L/min). The wheat flour samples were artificially contaminated with E. coli at a concentration of 9.25 ± 0.74 log CFU/g. ACP treatments with argon, air, and nitrogen resulted in 2.66, 4.21, and 5.55 log CFU/g reduction of E. coli, respectively, in wheat flour under optimized conditions. The optimized conditions to reduce E. coli were 0.5 g of the flour mass, 15 min of treatment time, and 0.20 L/min of nitrogen gas flow rate, and the predicted highest reduction level from modeling was 5.63 log CFU/g.