• 제목/요약/키워드: Biofilter media

검색결과 98건 처리시간 0.031초

엔통형 고정상 생물막법에 의한 고농도 유기성 폐수처리에 관한 연구 (A Study on the Treatment of a High-Strength Organic Wastewater by the Tube Type Fixed Biofilter Process)

  • 손종렬;장명배;문경환
    • 한국환경보건학회지
    • /
    • 제20권2호
    • /
    • pp.22-27
    • /
    • 1994
  • This study is to discuss the factors influenced on the removal efficiency of a high-strength organic wastewaters investigated using the polypropyrene media which appropriate to attach microorganism in the tube type fixed biofilter reactor. The results obtained in the experiment were as follows: 1. The kinetics of reaction rate (k') were 0.125, 0.135, 0.155 varing initial COD 720, 1280, 1630 mg/l in batch reactor. 2. In the range of pH 4.0 ~12.0 was obtained the removal efficiency of COD higher than 85%. It was proved that variation of pH (4.0 ~12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 3. Temperature to obtain removal efficiency of COD higher than 85% was 10 ~ 40$\circ$C. Removal efficiency of COD was no less than those at high temperature. 4. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/m$^3$.d below. And then the HRT was 8 hrs. 5. In comparison with the activated sludge process, the tube type fixed biofilter process was excellent in removal efficiency of substrate and sludge production rate.

  • PDF

실제 혼합염색폐수의 유동상 시스템을 활용한 미생물처리와 하이브리드 재순환시스템처리 (Treatment of an Authentic Textile-dyeing Wastewater Utilizing a Fluidized Biofilter and Hybrid Recirculating System Composed of the Fluidized Biofilter and a UV/photocatalytic Reactor)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제53권1호
    • /
    • pp.71-77
    • /
    • 2015
  • D염색공단의 폴리에스테르 알카리 감량폐수가 혼합된 실제 혼합염색폐수를 처리하기 위하여 Pseudomonas sp. 및 Bacillus cereus/thuringiensis를 고정한 폐타이어담체를 충전한 유동상 바이오필터를 운전하였다. 또한 유동상 바이오필터와 450 W의 UV/광촉매반응기를 결합한 하이브리드 재순환시스템을 구축하여 stage I에서는 UV/광촉매반응기를 바이패스하고 유동상 바이오필터만을, stage II-i, ii, iii에서는 하이브리드 재순환시스템을 각각 운전하였다. 유동상 바이오필터만을 사용하였을 경우에 $COD_{Cr}$ 및 색도 제거효율은 각각 75~80% 및 67%를 나타내었다. 한편 하이브리드 재순환시스템 운전에서 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 $COD_{Cr}$ 제거율이 20~30%에 달하여 총 $COD_{Cr}$ 제거율은 75%로부터 80~85%까지 제고되었다. 한편 stage I에서 stage II-i로 전환되었을 때에 UV/광촉매산화공정의 색도제거율은 0~5%에 불과하였으나 총 색도제거율은 45~65%로부터 65~70%까지 제고되었다. 색도 제거에서는 $COD_{Cr}$ 제거와 다르게 UV/광촉매산화공정에 의하여 유동상 바이오필터의 효율이 제고되어서 하이브리드 재순환시스템의 시너지효과가 나타났다. 또한 색도제거에서는 $COD_{Cr}$ 제거와 다르게 반송비 증가에 따른 광촉매 비활성화가 관찰되지 않았고, $COD_{Cr}$ 제거에서 반송비 증가에 따른 광촉매 비활성화는 비가역적으로 관찰되었다.

바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과 (Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House)

  • 송준익;최홍림;최희철;권두중;유용희;전중환
    • 한국축산시설환경학회지
    • /
    • 제13권3호
    • /
    • pp.195-200
    • /
    • 2007
  • 무창 육성 비육돈사에 대한 악취 제어 효율 비교분석을 위하여 Biofilter 덕트에 의한 악취 제어 연구를 수행하였다. 본 실험은 서울대 부속목장 실험돈사에서 실시하였으며 실험결과는 다음과 같다. 1. 무창 육성비육돈사에서 여름철 최대 배기시 바이오필터 외부로 배출되는 공기속도는 볏짚(.0.77 m/s), ALC(0.56 m/s)으로 측정되었다. 2. 실험시작 5일 후 가스검지기(GV-100)에 의한 간이측정시 암모니아($NH_3$) 농도는 필터 통과 후 볏짚($2mg/{\ell}$), ALC(3ppm)로 측정되어 부자재 사이의 공극율이 높은 볏짚이 높게 나타났다. 부자재에 따른 필터외부에서의 먼지측정 결과 볏짚($93\;mg/m^3$), ALC($32\;mg/m^3$)으로 측정되어 볏짚은 볏짚 간의 넓은 공극에서 발생하는 먼지 및 돈사내부의 먼지가 혼합되어 필터 외부로 배출되어 돈사내부보다 높게 측정되었다. 3. 황화수소($H_{2}S$) 가스농도 변화는 돈사내부에서는 측정일 7일(6 ppm), 21일(5 ppm) 및 36일(7 ppm) 경과함에 따라 어느 일정 시점에서 황화수소 가스농도는 증가하지 않았으나 다른 필터여재에서는 일정한 경향은 보이지 않았다. 이상의 실험결과를 종합해 볼 때 무창 육성비육 돈사에서 Biofilter를 이용한 악취저감 효과를 확인할 수 있었다.

  • PDF

활성탄 함유 폴리우레탄 담체를 사용하는 바이오필터에 의한 가스상 톨루엔의 처리 (Biofiltration of Gaseous Toluene Using Activated Carbon Containing Polyurethane Foam Media)

  • 알탐그렐 아말사나;신원식;최정학;최상준
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.513-525
    • /
    • 2006
  • In recent decades, biofiltration has been widely accepted for the treatment of contaminated air stream containing low concentration of odorous compounds or volatile organic compounds (VOCs). In this study, conventional biofilters packed with flexible synthetic polyurethane (PU) foam carriers were operated to remove toluene from a contaminated air stream. PU foams containing various amounts of pulverized activated carbon (PAC) were synthesized for the biofilter media and tested for toluene removal. Four biofilter columns were operated for 60 days to remove gaseous toluene from a contaminated air stream. During the biofiltration experiment, inlet toluene concentration was in the range of 0-150 ppm and EBRT (i.e., empty bed residence time) was kept at 26-42 seconds. Pressure drop of the biofilter bed was less than 3 mm $H_2O/m$ filter bed. The maximum removal capacity of toluene in the biofilters packed with PU-PAC foam was in the order of column II (PAC=7.08%) > column III (PAC=8.97%) > column I (PAC=4.95%) > column IV (PAC=13.52%), while the complete removal capacity was in the order of column II > column I > column III > column IV. The better biofiltration performance in column II was attributed to higher porosity providing favorable conditions for microbial growth. The results of biodegradation kinetic analysis showed that PU-PAC foam with 7.08% of PAC content had higher maximum removal rate ($V_m$=14.99 g toluene/kg dry material/day) than the other PU-PAC foams. In overall, the performance of biofiltration might be affected by the structure and physicochemical properties of PU foam induced by PAC content.

토양 혼합여재를 이용한 질소산화물 제거특성 (Removal Characteristics of NOx Using a Mixed Soil-Biofilter)

  • 조기철;신은상;황경철;조일형;이내현;여현구
    • 환경위생공학
    • /
    • 제21권3호
    • /
    • pp.15-26
    • /
    • 2006
  • As traffic in city-centre around the world continues to increase, so levels of atmospheric pollutants continue to rise. High concentrations of NOx can have negative effects on human health, and we must find new ways to reduce their levels in the air we breathe. Nitrogen oxide gas (NOx), consisting of nitrogen monoxide (NO) and nitrogen dioxide $(NO_2)$ produced using $O_3$ oxidation, at a low concentration corresponding to that on roads as a result of exhaust from automobiles, was carried out to evaluate the removal characteristics of NOx through a laboratory-scale biofilter packed with soil as a packing material. A mixture media (yellow soil (30%): soil (40%): compost (10%): a used briquet (20%)) was applied. After about 1day of operation, the removal efficiency for $NO_2$ in all experiments with a constant condition ($25^{\circ}C$ and water humidity (60%)) was over 98%. The retention times of the section between phase I and phase II for formation and reduction of $NO_3$ NO and $NO_2$ on the initial $NO_3$ concentration was 50min $(O_3:195\;ppb),\;55min\;(O_3:925\;ppb),\;65min\;(O_3:1743\;ppb),\;70min\;(O_3:2616\;ppb),\;75min\;(O_3:3500\;ppb)$, respectively The soil biofilter system is a unique technology that purifies urban air by utilizing the natural processes that take place in the soil. Although some of the processes are quite complex, they can broadly be summarized as adsorption onto soil particles, dissolution into soil pore water, and biochemical.

간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성 (Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB))

  • 허목;강진영;김광진
    • 유기물자원화
    • /
    • 제11권2호
    • /
    • pp.125-131
    • /
    • 2003
  • 본 연구는 오수중의 유기물 및 질소 인의 동시제거를 위한 오 폐수 고도처리장치인 간접폭기형 침적생물막여과장치(Indirected Aerated Submerged Biofilter : INSUB)를 개발하기 위하여 실험실적 모형실험을 수행하였다. INSUB에서 오수를 처리함에 있어서, HRT 18시간, 공탑속도 42.5m/hr, 충전율 40%인 경우가 실제로 경제적인 효율을 고려하였을 때, 가장 효율이 좋았다. 각각의 제거효율을 살펴보면, $COD_{cr}$, 90.6%, $COD_{Mn}$ 85.3%, $BOD_5$ 95.0%, T-N 52.3% 그리고 T-P 56.8%로 나타났다. 질소 인의 고효율처리를 위해서는 전탈질공정에 의한 산화질소의 제거를 위해 무산소, 호기조의 조합 등에 의한 system의 일부 다단화가 필요함을 확인할 수 있었다.

  • PDF

생물막공정에 의한 상수원수의 수질개선에 관한 연구 (A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter)

  • 이수식;안승섭
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

Bioscrubber Trickling Filter(BSTF)의 VOCs 제거 및 운전 특성에 관한 연구 (A Study on the Removal Efficiency of VOCs and Operating Characteristics by Using of Bioscrubber Trickling Filter(BSTE))

  • 박진도;서정호;이학성
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.309-315
    • /
    • 2005
  • Volatile organic compounds (VOCs) and odor materials are major sources of air pollution in Ulsan city, where much chemical plants are located. Therefore, it is necessary to develop a new reactor which can remove VOCs and odor materials effectively and be equipped at the end of pipe easily. A modified reactor (bioscrubber trickling filter, BSTF), which have both characteristics of biofilter and bioscrubber, was developed and tested on its reactivity with several VOCs using two types of media, fiber and activated carbon 4- ceramic(A/C). It was observed that the removal efficiencies of several types of VOCs such as acetaldehyde, ethylalcohol, butanol, diethylamine and triethylamine were up to $95\%$ when they had about 100 ppm of initial concentration and 80 seconds of residence time. Good attachment of microorganisms to both media, where it is thought the reaction efficiency can be determined according to the amount of microorganisms attachment, observed with scanning electron microscopy(SEM). Initial pressure drops of the packed bed with both media were 229 $mmH_2O/m$ at A/C column and 670 $mmH_2O/m$, respectively. However, maximum pressure drop of fiber column during the operation was over 1,647 $mmH_2O/m$. Therefore, it was thought that the fiber material would not suitable to use in the local plant as a packed bed media.