• Title/Summary/Keyword: Bioelectric

Search Result 64, Processing Time 0.024 seconds

The clinical manifestation of migraine and correlation study with autonomic bioelectric response (편두통 환자의 임상 양상 및 생체전기 자율반응과의 상관성 고찰)

  • Lee, Hyun-jong;Jung, In-tae;Kim, Su-young;Lee, Doo-ik;Kim, Keon-sik;Lee, Jae-dong;Lee, Yun-ho;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.215-229
    • /
    • 2004
  • Objective : We had a clinical report in headache but didn't in migraine. We have planned this study in order to get the basic data of migraine in oriental medicine. Methods : The patient of 36 in migraine checked sex, age, onset, family history, severity of pain, influences of life, induced cause, clinical pain characteristics, associated symptom, treatment style, and prescription, frequency, using period of analgesics by a questionnaire and differentiated syndromes in migraine and evaluated autonomic bioelectric response recorder(ABR-2000). Results : There are 23.4% in prevalence rate of migraine. The ratio of sex is M:F=1:17. The age of an attack is the highest in thirties. The patient are the most in forties. The mean duration of illness is $12.0{\pm}9.9$ years. 83.4% had a family history. 61.1% had a moderate grade in severity of pain. 77.8% selected fatigue in induced cause of migraine. 69.4% had tingling sense, nausea and vomiting in the associated symptoms. 91.7% used analgesics for treatment and 51.5% of them used analgesics voluntarily. 61.9% of them take analgesics less than once in a week. 33.6% had the phlegm syncope headache in differentiation of syndrome. In ABR-2000 results, item of graph showed low tendency mostly. Conclusions : We expected that this report of clinical progress, differentiation of syndromes and ABR-2000 results in migraine would be used basic data by oriental medicine to treat migraine.

  • PDF

Development of Exercise Analysis System Using Bioelectric Abdominal Signal (복부생체전기신호를 이용한 운동 분석 시스템 개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.183-190
    • /
    • 2012
  • Conventional physical activity monitoring systems, which use accelerometers, global positioning system (GPS), heartbeats, or body temperature information, showed limited performances due to their own restrictions on measurement environment and measurable activity types. To overcome these limitations, we developed a portable exercise analysis system that can analyze aerobic exercises as well as isotonic exercises. For bioelectric signal acquisition during exercise, waist belt with two body contact electrodes was used. For exercise analysis, the measured signals were firstly divided into two signal groups with different frequency ranges which can represent respiration related signal and muscular motion related signal, respectively. After then, power values, differential of power values, and median frequency values were selected for feature values. Selected features were used as inputs of support vector machine (SVM) to classify the exercise types. For verification of statistical significance, ANOVA and multiple comparison test were performed. The experimental results showed 100% accuracy for classification of aerobic exercise and isotonic resistance exercise. Also, classification of aerobic exercise, isotonic resistance exercise, and hybrid types of exercise revealed 92.7% of accuracy.

Influence of Bioelectric Current on the Acupuncture: A Pilot Study - Focusing on the Effect of PC6 Against Heart Rate - (생체전류가 침 치료에 미치는 영향: 예비연구 - 심박수에 대한 내관(內關) 자침 효과를 중심으로 -)

  • Lee, Bong Hyo;Park, Ji Ha;Kim, Hee Young;Kim, Seong Rok;Park, Yeo Bin;On, Ye Jin;Lee, Seung Su;Lee, Chang Wook;Han, Soo Yeon;Lim, Sung Chul;Kim, Jae Soo;Lee, Yun Kyu;Lee, Hyun Jong;Jung, Tae Young;Lee, Sang Nam
    • Korean Journal of Acupuncture
    • /
    • v.30 no.3
    • /
    • pp.185-192
    • /
    • 2013
  • Objectives : Many studies have investigated the electric specificity of meridian and acupoint. However, the definition about the real substance of 'Ki(Qi)' that flows in the meridian has not been established yet. The authors hypothesized that the 'Ki(Qi)' may be the very 'bioelectricity' of western medicine, from two common features that they are not visible with naked eyes and that they function in the living body only. Methods : 20 healthy adults participated in this study. Heart rate was measured before and after exercise. Acupuncture was performed at PC6 immediately after exercise with counter balance in the first experiment. In the second experiment, acupuncture group was further divided to the three groups, i.e. glove acupuncture group, manual acupuncture group, and NaCl acupuncture group. In the glove group, acupuncturist put on the two folds of latex gloves to block bioelectric currents between the acupuncturist and subject. In the NaCl group, acupuncturist had his fingertips wet with NaCl solution. Results : Exercise increased Heart Rate and acupuncture at PC6 inhibited this increase. In the second experiment, the significant difference compared to the comtrol group was the most in NaCl acupuncture and the least in Glove acupuncture. However, there was no significant difference between three groups. Conclusions : The results of this study seem to be deficient as a conclusive evidence for the hypothesis that the 'Ki(Qi)' of Korean Medicine is the 'bioelectricity' of western medicine.

Study on the Reliability of Electromygraphic Examine according to the Measurement Timing in a Day (근전도 측정시 검사시간에 따른 신뢰도 연구)

  • Woo-Cheon Kee;Byung-Guk Kim;Sook-Hee Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.19-24
    • /
    • 1989
  • The purpose of this study was to investigate the reliability of electromyographic examination in a day and detect the objective measurement timing of electromyography. 18 normal students who were in dental collage of C national university were selected for this study. They had no symptoms on temporomandibular joint area, no restorations and missing tooth on dentition. Their molar relationship was normal or class I of Angle's classification. Electromyography had been taken every one hour from 9:00 A.M. to 5:00 P.M. in the state of clenching and rest by using Bioelectric processor EM2 interfaced with mandibular kinesiograph K-6 diagnostic system. We compared and analyzed the variances of electromyography values of each subjects. The obtained results were as follows : There were no significant differences on variability of electromyography values in each state clenching and rest. In the aspect of this circumstances, the use of electromyography could be a good objective procedure to diagnose the temporomandibular disorders and to detect the effect to the treatment of temporomandibular disorders at any time in a day from 9:00 A.M. to 5:00 P.M.

  • PDF

A Study on the Effects of Occlusal Stabilization Splint on Electromyographic Activity (교합안정장치의 장착이 저작근 활성도에 끼치는 영향에 관한 연구)

  • Min Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.14 no.1
    • /
    • pp.67-80
    • /
    • 1989
  • The author studied the changes of muscle activity with Bioelectric processor Model EM2(Myotronics Corp., USA) before and after occlusal stabilization splint therapy. For this study, 15 temporomandibular disorders patients and 15 students without any temporomandibular disorders symptoms were selected, for experimental group and control group, respectively. Experimental group were treated with occlusal stabilization splint and checked about electromyographic activity before and after therapy. Electromyographic levels were measured in both groups at the following mandibular position, i.e., physiologic rest, tapping, light biting, hard open without pain, open with pain, right excursion and ipsilateral biting, left excursion and ipsilateral biting, protrusion, protrusive biting, edge biting and physiologic rest after movement. The obtained results were as follows : 1. In experimental group, post-treatment mean values of muscle activity were lower than pretreatment values. 2. In general, the pre-treatment mean values of muscle activity in experimental group were higher than those of control group. 3. In experimental group, no statistically significant difference appeared between affected and unaffected side. 4. The mean value of muscle activity in physiologic rest position after each movement check was lower than that before each movement check.

  • PDF

A Study of the Development of 24ch. Meridian Electric - Potential Measuring System (24 채널 경락 전위 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;SaKong, Sug-Chin
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.1-6
    • /
    • 2005
  • The 24 channel meridian electric-potential measuring System consists of a main cpu module, bio-signal analog module, interface module, power module, personal computer. The graphic user interface program conveniently allows user to setup, calibrate, measure, store, and control the meridian electric-potential measuring system. This system and program will continually be evolved using a database of clinically correlated meridian electric-potential. A variety of system configurations gives it the ability to make a user-favorable environment for measuring.

THE INFLUENCE OF OCCLUSAL CHANGE ON THE MASTICATORY MUSCLE ACTIVITY (교합접촉의 변화가 저작근 활성도에 미치는 영향에 관한 연구)

  • Mun, Sang Bin;Yoon, Min Eui;Jin, Tai Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.175-182
    • /
    • 1990
  • This study was performed to investigate the influence of occlusal change on the masticatory muscle activity. 8 students without any symptom of T.M.J. dysfunction, any history of prosthodontic or orthodontic treatment on dental college of WonKwang Univ. were participated in this study. The activity of masseter and anterior temporal muscles were measured by bioelectric processor(EM2, Myotronics, Inc., U.S.A.) during voluntary maximal clenching on natural teeth, by splint with bilateral posterior surface contact, by splint with unilateral posterior surface contact, and by splint without unilateral posterior teeth contact. The obtained results were as follows ; 1. The loss of posterior contact on noe side resulted in change of the activity of anterior temporal and masseter muscle during clenching on ipsilateral side, but there was no change of muscle activity on contralateral side. 2. The activity of anterior temporal and masseter muscle during clenching were not affected by the pattern of occlusal contact. 3. There were no difference between the activity of anterior temporal and masseter miuscle during clenching by natural teeth and by occlusal splint.

  • PDF

Electrode Characteristics of Non-contact Electrocardiographic Measurement

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.1
    • /
    • pp.42-45
    • /
    • 2015
  • The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.

Effect of Cold Acclimatization Training on Body Composition (추위 훈련이 신체 조성에 미치는 영향 -체중, 체지방량, 골격근량을 중심으로-)

  • Park, Joo-Hee;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.7
    • /
    • pp.713-720
    • /
    • 2011
  • This study investigated the effect of cold acclimatization training on body composition including weight, fat mass, and muscle mass with 10 subjects (5 males and 5 females). During the 3-week acclimatization training program, they visited an artificial climate chamber ($15^{\circ}C$) 15 times and were exposed to cold environment with light clothing for 2 hours. Body composition was measured before and after cold training using bioelectric impedance analysis that was later compared by a paired t-test. In the process of thermoregulation, muscle contraction was accompanied by increased substrate metabolism for rising heat production. After cold training, the muscle mass increased and fat mass decreased significantly (p<.1, p<.05), subsequently the body composition changed. It was found that cold acclimatization training could be used as a treatment for obesity. It was suggested that further investigation on the long term effects of mild cold exposure using clothing and its potential applicability as an obesity treatment.

The Multi-channel Bio-potential Similarity Research of Acupuncture Point (ST36) and Peripheral Region (다채널 생체전위 측정을 통한 족삼리 주변 피부의 전위 변화 유사도 연구)

  • Lee, Sang-Hun;Cho, Sung-Jin;Choi, Gwang-Ho;Ryu, Yeon-Hee;Kwon, O-Sang;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.41-48
    • /
    • 2011
  • Objectives : This study aimed to explore the passive multi-channel time series analysis method by measuring bio-potentials of acupuncture point and the peripheral region Methods : Bio-potential was measured at ST36 and the peripherical region of ST36 of 5 healthy volunteers at three times. The diagram of the potential changes over time were smoothed by moving average method and similarities of ST36 and the other points were calculated. Results : In the normal weight group, bio-potential similarity tended to decrease in proportion to the distance from the acupuncture point. In the obesity group, bio-potential similarity appeared in a very wide area. Bio-potential similarity had positive correlation with BMI value. Conclusions : The passive multi-channel time series analysis method showed the possibility be appropriate for the electrical characteristics study of meridians.