• Title/Summary/Keyword: Biodex

Search Result 141, Processing Time 0.019 seconds

The Utility of Measuring Paravertebral Muscle Function with 3D-NEWTON (3차원 뉴튼(3D-NEWTON)을 이용한 척추 주위근 기능 평가의 유용성)

  • Han, Nami;Kim, Hyun Dong;Hwang, Ji Sun;Bae, Jung-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.1
    • /
    • pp.16-22
    • /
    • 2013
  • Purpose: This study evaluated the validity of measuring paravertebral muscle function with 3D-NEWTON (Hanmed, Korea) by assessing the correlation between Biodex (Biodex, USA) and surface electromyography (EMG). Methods: Nineteen healthy adults participated. The function of their paravertebral muscle was measured in three ways. Maximum endurance time was measured in seconds when 3D-NEWTON was inclined forward for assessing extensor function, and inclined backward for assessing flexor function. Using surface EMG, maximum muscle activity was obtained from the eractor spinae and rectus abdominis during the 3D-NEWTON measurement. Maximum muscle activity was the mean activity from 10 seconds when the root mean squared firing data was highest. Through Biodex the peak torques of the extensor and flexor were measured during isometric exercises. The Spearman correlation coefficiencts from 3D-NEWTON, surface EMG, and Biodex were calculated. Results: The data from surface EMG and Biodex were statistically correlated when measured for flexor function, but less so for extensor function. In the case of 3D-NEWTON, the correlation coefficient with Biodex was 0.50 (p=0.05), while the coefficient with surface EMG was 0.53 (p=0.02) when measured for extensor function. Similarly, the correlation coefficienct with Biodex was 0.60 (p=0.01), while the surface EMG was 0.51 (p=0.03) for flexor function. Conclusion: 3D-NEWTON was a useful method for measuring paravertebral muscle function and can give helpful information for treating people with diseases associated with the lumbar spine.

The Effect of Proprioceptive Exercise on Knee Active Articular Position Sense Using Biodex System 3pro®

  • Park, Jae-Yong;Lee, Jung-Chul;Bae, Jong-Jin;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.3
    • /
    • pp.170-173
    • /
    • 2014
  • In order to assess the impact of proprioceptive exercises on the position sense ability of the knee joint, we conducted an analysis using Biodex System $3pro^{(R)}$, targeting 42 ordinary people (male=22, female=20). After applying proprioceptive exercise, we measured changes in balance and flexibility, and active articular position sense (AAPS), depending on gender. To find out the change in each measurement item variable, we carried out dependent t-tests. The statistical significance level was set to 0.05. The research showed that after applying the proprioceptive exercise, AAPS was significantly improved for both men and women (p<.01). In the case of women, the flexibility was significantly improved (p<.01). Also, the balance was significantly improved for both men and women (p<.01). Therefore, the proprioceptive exercise program is considered to be very useful in improving muscle and joint function, and preventing injuries. Thus, continuous clinical studies using Biodex system $3pro^{(R)}$ are required for a variety of scientific evaluations of proprioceptive skills.

Identification of Spastic Joint Pathologies using Isokinetic Movement (등속운동을 이용한 경직성 관절장애 정량화)

  • Lee Chang-Han;Heo Ji-Un;Kim Chul-Seung;Eom Gwang-Moon
    • Science of Emotion and Sensibility
    • /
    • v.7 no.4
    • /
    • pp.19-24
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque. Therefore, the estimation of damping property from the isokinetic movement is difficult.

  • PDF

Validity Study of Dynamic Balance Abilities Measure using a Smartphone (스마트폰을 이용한 동적균형능력 측정의 타당도 연구)

  • Han, Seul-Ki;Lee, Sang-Yong;Lee, Dae-Hee;Park, Jung-Seo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.77-82
    • /
    • 2016
  • PURPOSE: The purpose of this study was to investigate the validity of dynamic balance measurements using a smartphone. METHODS: Thirty subjects were selected out of Y-university students without fractures, operation history, and inflammatory arthritis who had not started regular exercise during the past three months. Their dynamic balance ability was measured by the Biodex Balance System (Biodex Medical Systems, Inc., USA) using smartphones. The smartphone utilized in this study was the Galaxy Note4 LTE (SM-N910K, Samsung, Korea), and the application was the Sensor Kinetics pro (Ver.2.1.2, INNOVENTIONS Inc, US). The dynamic balance ability was measured in triplicate. RESULTS: With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the roll value of the smartphone gyroscope versus the medial/lateral score of the Biodex Balance System. With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the total value of the smartphone gyroscope versus the total score of the Biodex Balance System. CONCLUSION: This study indicated that using a smartphone can generate highly limited data regarding balance ability. They are unlikely to replace the existing more expensive devices entirely. However, smartphones may be highly useful in environments in which an expensive device is not available or when dynamic balance ability should be measured immediately or within a few hours.

Quantitative Relationship between Body Composition and Muscular Strength Measured with the Biodex System 3 (Biodex System3을 사용한 근력측정과 체조성의 양적조건과의 관련성)

  • Lee, Sang-Un;Kim, Yong-Kwon;Sato, Kouki
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.208-215
    • /
    • 2003
  • This study measured body composition and muscular strength, to examine their relationship, using the Bioelectrical Impedance (IB) method and biodex system3, respectively, in 44 healthy male(20) and female(24) university students. 1. Muscular strength of the upper extremities correlated significantly with fat-free mass(FFM) with $r=.604{\sim}.630$ and intracellular fluid(ICF) with $r=.672{\sim}.668$ in males and FFM with $r=.416{\sim}.552$, ICF with $r=.432{\sim}.564$ and extracellular fluid(ECF) with $r=.429{\sim}.463$ in females. 2. Muscular strength of the lower extremities correlated significantly with FFM with $r=.522{\sim}.785$, ICF with $r=.501{\sim}.739$ and ECF with $r=.498{\sim}.796$ in males and FFM with $r=.642{\sim}.660$, ICF with $r=.627{\sim}.671$ and ECF with $r=.572{\sim}.623$ in females. 3. Muscular strength of the trunk correlated with FFM with $r=.595$, ICF with $r=.627$, ECF with $r=.448$ in males, but did not correlate significantly with body composition in females. These results suggest that total body water(TBW) and ICF may be factors directly associated with muscular strength as well as physical fitness.

  • PDF

The Effects of Isokinetic Exercise on Knee Joint Combined Russian Current Stimulation

  • Kim, Dong-Hoon;Jung, Ho-Bal
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.5
    • /
    • pp.351-355
    • /
    • 2015
  • Purpose: This study was conducted to determine how stimulation using Russian current changes isokinetic exercise performance of quadriceps muscle and its antagonist muscles. Methods: Subjects were 20 20-year-old healthy adults who were instructed in the flexion to extension of knees in angular velocity $60^{\circ}/sec$ and $180^{\circ}/sec$ using a Biodex (Biodex system 3). We measured the difference in muscle performance between the Russian current stimulated at the same time during the flexion to extension of knees and not stimulated. Results: The results showed that when Russian current stimulation was applied at the angular velocity $60^{\circ}/sec$, the flexed and extended muscles and the angular velocity $180^{\circ}/sec$ increased significantly, but the peak torque of flexing muscles at the angular velocity $180^{\circ}/sec$ did not increase. Conclusion: These findings suggest that Russian current stimulation with isokinetic exercise of the knee joint could affect the quadriceps muscle and its antagonist muscle performance of muscle strength and endurance.

Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement (등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가)

  • 이창한;허지운;김철승;엄광문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF

The Effects of Strengthening Exercise of Hip Abductors on Muscle Strength and Ambulation in Patient with ACL Reconstruction (앞십자인대 재건술 후 엉덩관절 벌림근 강화운동이 근력과 보행에 미치는 영향)

  • Park, Byung-Joon;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.5
    • /
    • pp.296-301
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of strengthening exercises of hip abductors on muscle strength and ambulation for patients with ACL reconstruction. Methods: The subjects were randomly assigned to the intervention group (general exercise plus strengthening of hip abductors) or the control group (general exercise without the strengthening of hip abductors). Both groups participated in a six-week exercise protocol after the surgery for ACL reconstruction. The knee strength test (quadriceps, hamstring, hip abductor) and gait analysis were performed in pretest and post-test. Results: Muscle strength was measured using the Biodex system III model (Biodex Medical System, Inc, NY, US). The results showed no significant difference in knee strength (quadriceps, hamstring) between the two groups (p>0.05), however, there was a significant difference in hip abductors (p<0.05). The gait analysis was measured with Gaitrite system (CIR System Inc, US). Results of comparison between groups showed a significant increase in the step length of both groups. (p<0.05), and there was a significant difference in the affected leg of the intervention group(p<0.05). Conclusion: Exercise of hip abductors for patients with ACL reconstruction provides significant benefits with respect to improvement of muscle strength in hip abductors, increasing the stride. This result indicates that a training program designed for ACL reconstruction patients should include strengthening of the hip abductor. We think that further study is needed to determine the relationship of hip muscles and knee joint for patients with ACL reconstruction.

Assessment of Isokinetic Muscle Function, Balance and Flexibility in Elite High School Kayakers (고등학교 엘리트 카약 선수들의 등속성 근기능·균형성·유연성 측정 및 평가)

  • Shin, Kwang-Taek;Sohn, Jee-Hoon
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.407-416
    • /
    • 2018
  • The purpose of this study is to evaluate elite high school kayaker's iso-kinetic muscle function and provide physical training advices. Biodex system IV, Biodex stabilizer system, Inbody 3.0 and CNP-5403 are used to investigate 11 kayaker's muscle function(peak torque, average power and work fatigue), dynamic balance, body compositions, and flexibility. S4, S5, S8, S10, S11 are needed to train shoulder muscle strength and power. S5, S6, S10, S11 are needed to strengthen shoulder muscle endurance. S5, S7, S8, S10, S11 are needed to train knee muscle strength and power. S1, S4, S5, S10 are needed to strengthen knee muscle endurance. S3, S10, S11 are needed to train wrist muscle endurance. Based on these results we should establish an muscle function enhancing program with periodic inspection for elite kayakers. And standardized training program should be sublated.

Assessment of Isokinetic Muscle Function in Elite Canadian College Paddlers (대학 엘리트 카나디언 선수들의 어깨·허리·무릎 관절의 등속성 근기능 평가 및 진단)

  • Shin, Kwang-Taek;An, Chang-Gyu;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.229-238
    • /
    • 2013
  • The aim of this study is to evaluate university canadian paddlers' iso-kinetic muscle function and provide training advices. Eight university paddlers with a 8.5 years career participated in this study. Inbody 720, biodex system III, biodex stabilizer system and THP 2 are used to investigate body component, muscle function(peak torque, average power and work fatigue), agility and dynamic balance. Iso-kinetic muscle function around shoulder, thorax and knee are measured. And then bilateral and unilateral muscle imbalance are calculated at each joint. Results of this study are as follows; University canadian paddlers' BMI average is 24.90 $kg/m^2$ and percent body fat is 12.23%. Reaction time average was 324 msec and balance score at each leg are below 2.0. A3, A4, A5, A6, A8 are needed to train shoulder muscle strength and power. A1, A2, A7, A8 are needed to strengthen shoulder muscle endurance. A2, A5, A8 are needed to train thorax muscle strength and power. A1, A8 are needed to strengthen thorax muscle endurance. Most of paddlers' reciprocal muscle balance ratio on thorax and knee are out of normal range. A2, A3, A4, A8 are needed to train abdominal strength and A3, A5, A6, A7, A8 are needed to train hamstring strength.