• Title/Summary/Keyword: Biochemical oxygen demand

Search Result 234, Processing Time 0.022 seconds

Estimation of Pollutant Loads Delivery Ratio by Flow Duration Using Regression Equation in Hwangryong A Watershed (회귀식을 이용한 황룡A 유역에서의 유황별 유달율 산정)

  • Jung, Jae-Woon;Yoon, Kwang-Sik;Joo, Seuk-Hun;Choi, Woo-Young;Lee, Yong-Woon;Rhew, Doug-Hee;Lee, Su-Woong;Chang, Nam-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.25-31
    • /
    • 2009
  • In this study, pollutant loads delivery ratio by flow duration in Hwangryoung A watershed was estimated. The delivery ratio was estimated with measured data by Ministry of Environment(MOE) and the regression equation based on geomorphic parameters. Eight day interval flow data measured by the MOE were converted to daily flow to calculate daily load and flow duration curve by correlating data of neighboring station which has daily flow data. Regression equation developed by previous study was tested to study watershed and found to be satisfactory. The delivery ratios estimated by two methods were compared. For the case of Biochemical oxygen demand(BOD), the delivery ratios of low flow condition were 7.6 and 15.5% by measured and regression equation, respectively. Also, the delivery ratios of Total phosphorus(T-P) for normal flow condition were 13.3 and 6.3% by measured and regression equation, respectively.

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Study of the Influence of Heavy Metal Ions(Cu, Cr, Pb, Zn) on Biochemical Oxygen Demand (BOD 測定에 影響을 미치는 重金屬이온에 關한 연구)

  • Choi, Taek-Pyul;Yun, O-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.9 no.2
    • /
    • pp.75-81
    • /
    • 1983
  • The Biochemical Oxygen Demand(BOD) indicates that microbes are proliferating or that oxygen is being spent by breathing action when examining water under the same aerobic condition. In this research of the mesurement of BOD are the poisonous elements of heavy metal ions such as Cu-ion, Cr-ion, Pb-ion and Zn-ion. They exert an unfavorable influence in the analysis of BOD and research was performed to provide certain data of minimum negative influence by the poisonous matters. The results of the research confirm that heavy metal ion(Cu, Cr, Pb, Zn) do direct an influence upon the normal growth of aerobic microbes in actual tests of chemical analysis of portable water or sewage. The most critical concentration for a negative effect on lowering oxygen quantity and disturbing the aerobic mocrobes normal growth was found to be 0.01 mg/l. Therefore, test results are not valid if the heavy metal concentration is to or greater than 0.0mg/l, To improve comprehension through out the research the author uses the following abbreviations: 1. The Cu-ion is to be excluded before experimental analysis if it is over 0.01mg/l inorder to obtain a real value for the BOD. 2. The Cr-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 3. The Pb-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 4. The Zn-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD.

  • PDF

Dairy wastewater treatment using microalgae for potential biodiesel application

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.393-400
    • /
    • 2016
  • The aim of this study was to evaluate the biomass production and dairy wastewater treatment using Chlorella vulgaris. The results indicated that the maximum percentages of biochemical oxygen demand, chemical oxygen demand, suspended solids, total nitrogen, and total phosphorus removed were 85.61%, 80.62%, 29.10%, 85.47%, and 65.96%, respectively, in dairy effluent at 10 d. A maximum of 1.23 g/L dry biomass was obtained in 7 d. The biomass productivity was strongly influenced by the nutrient reduction in the dairy effluent. The biodiesel produced by the C. vulgaris in the dairy effluent was in good agreement with the American Society of Testing and Materials-D6751 and European Standards 14214 standards. Therefore, using dairy effluent for microalgal cultures could be a useful and practical strategy for an advanced, environmentally friendly treatment process.

Parametric study of brewery wastewater effluent treatment using Chlorella vulgaris microalgae

  • Choi, Hee-Jeong
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.401-408
    • /
    • 2016
  • The aim of this study was to evaluate the biomass and lipid production of Chlorella vulgaris and its nutrient removal capability for treatment of brewery wastewater effluent. The results indicate that the maximum biochemical oxygen demand (BOD) (91.43%) and chemical oxygen demand (COD) (83.11%) were removed by C. vulgaris with aeration in the absence of light. A maximum of 0.917 g/L of dry biomass was obtained with aeration in the dark conditions, which also demonstrated the highest amount of unsaturated fatty acids at 83.22%. However, the removal of total nitrogen (TN) and total phosphorus (TP) with these aeration and light conditions was 9.7% and 11.86% greater than that of other conditions. The removal of BOD and COD and the production of biomass and lipids with aeration in the dark and the TN and TP removal with aeration and light were more effective than other conditions in the brewery wastewater effluent in the presence of C. vulgaris.

Optimization of Ozone Oxidation process for Decolorization form dyeing wastewater (염색폐수 색도저감을 위한 오존산화공정의 최적화)

  • Sin, Dong-Hun;Choe, Jang-Seung;Lee, Sang-Heon;Kim, Seong-Jin;Ryu, Seung-Han;Park, Jun-Hyeong;Choe, Seong-Uk
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2008.10a
    • /
    • pp.115-116
    • /
    • 2008
  • The textile wastewater discharged from printing and dyeing processes is characterized by high chemical oxygen demand(COD), low biochemical oxygen demand(BOD), and heavy color. The release of dyes into the environment constitutes only small proportion of water pollution, but dyes are visible in small quantities due to their brilliance. In this study, We are investigated to optimization of Ozone Oxidation process for Decolorization.

  • PDF

지하수의 채취 및 전처리 방법에 따른 TOC 농도변화

  • 조수영;윤윤열;이길용;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.413-416
    • /
    • 2004
  • TOC(total organic carbon)분석은 폐수 및 강수의 오염특성을 평가하기 위한 도구로서 BOD(biochemical oxygen demand), COD(chemical oxygen demand) 와 함께 사용되어 왔다. TOC 측정시간은 10분 정도로 BOD(5~6일), COD(2~3시간)에 비해 아주 짧은 시간에 측정할 수가 있으며, 전처리과정이 단순하고 정확도도 높은 것으로 알려져 있다. 본 연구는 지하수의 잠재오염성을 밝혀내기 위한 도구로 TOC를 활용하여 신뢰성 있는 분석 값을 얻기 위해서 시료의 채취, 보관, 측정까지의 최적 조건을 도출하는데 목적을 두었다. 아울러 시료 채취 후 일정 경과 시간에 따른 TOC의 변화를 관찰하였다. 시료채취 용기, 채취 후 산성화, 보관방법 및 기간에 대한 실험 결과, 대상 변수에 따라서 TOC의 농도변화에 커다란 차이점을 볼 수 있었다. TOC 농도가 낮은 지하수시료의 측정에서는 빛을 차단시킨 불투명 유리병을 사용해야만 하고 채취 즉시 산도를 높여(pH<2)주며 4$^{\circ}C$ 이하에서 보관하여야 한다. 지하수중 TOC 측정시료는 가능한 보관 기간에 있어서 채수 후 24시간 이내에 측정하는 것이 좋으나 1) 본 연구에서는 채취현장과의 거리를 고려하면 현실적으로 불가능하므로 기간에 따른 TOC 변화를 30일까지 측정, 조사하였다.

  • PDF

Treatment of Organic Waste with Microorganisms of Mixed Population

  • Kim, Gi-Eun
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.129-133
    • /
    • 2007
  • This study represents that a removal efficiency of organic matters in wastewater is activated by a sludge process using new mixed microbial population. In case of mixed microorganisms, removal rates of suspended solid (SS), biochemical oxygen demand (BOD) and chemical oxygen demand (COD) were over 90 percent under experimental condition, and removal efficiency of organic matters, sludge density index (SDI) and capillary suction time (CST) in mixed population were higher than that in not-mixed microorganism, while total kjeldahl nitrogen (TKN) and total phosphorus (T-P) which indicate a degree of eutrophication were removed easily in both case. From these results, we may propose that an application of the mixed microbial population is useful to treat domestic wastewater including a great deal of organic matters.

A Study on the Software development for the correlation of the water pollution of pollution material analysis (공해물질분석에 관한 수질오탁의 상관성 계산 위한 SOFTWARE 개발에 관한 연구)

  • 택훈
    • Journal of the Speleological Society of Korea
    • /
    • v.15 no.16
    • /
    • pp.38-60
    • /
    • 1987
  • There are BOD(Biochemical Oxygen Demand) and COD(Chemical Oxygen Demand) in the date of the water pollution in the pollution analysis, BOD and COD analysis the result of the analysis. The computer developed the program in the analysis. Went by BOD, the relation conversion equation type of COD, the control chart, the standard deviation, and the coefficient of correlation etc.. for the purpose of the development of the program. There is a purpose by which it is what coefficient of correlation in the development of this program or not if the value (X and Y) of unknow is understood. In the future, if this program is applied the utilization to not only the data is analyzed about the water pollution but also a lot of fields is proposed.

  • PDF

Research on the Amount of Wastewater Produced from the Different Milking System (착유시스템별 세척수 발생량에 관한 연구)

  • 최동윤;강희설;곽정훈;최희철;김재환;김태일;이덕수;권두중;한정대
    • Journal of Animal Environmental Science
    • /
    • v.7 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • This research was carried out to investigate the daily amount and characteristics of wastewater produced from bucket milkers, pipeline, tandem ad herringbone milking system for washing operations after milking included 28 dairy farms. The average amount of wastewater produced from milking system was 9.8l/head/day. The amount of wastewater varied from a low of 8.2 litters/head/day(pipeline milking system) to 13.4 litter/head/day(herringbone milking system). The moisture content, Biochemical Oxygen Demand($BOD_5$), Chemical Oxygen Demand($COD_{Mn}$), Suspended Solids(SS), Total Nitrogen(T-N) and Total Phosphorus(T-P) concentration of wastewater were 99.9%, 394mg/l, 417.3mg/l, 1,201.3mg/l, 3.78mg/l, 0.51mg/l.

  • PDF