• Title/Summary/Keyword: BioSignal

Search Result 673, Processing Time 0.027 seconds

Multi-access Monitoring System for Biological Signal Collection (생체신호수집을 위한 다중접속 모니터링 시스템)

  • Kim, Tae-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.1
    • /
    • pp.145-148
    • /
    • 2020
  • Wearable computing is growing rapidly as research on body area communication network using wireless sensor network technology is actively conducted. In particular, there is an increasing interest in smart clothing measuring unrestrained and insensitive bio signals, and research is being actively conducted. However, research on smart clothing is mainly based on 1: 1 wireless communication. In this paper, we propose a multi-access monitoring system that can measure bio-signals by multiple users wearing smart clothing. The proposed system consists of wireless access device, multiple access control server and monitoring system. It also provides a service that allows multiple users to monitor and measure bio signals at the same time.

A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors (자기 임피던스 센서를 이용한 맥박 측정 장치)

  • Kim, Cheong-Worl;Gu, Bon-Ju;Kim, Jong-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Effects of Three Recumbent Postures on Autonomic Nervous System in Patients with Coronary Artery Disease

  • Kim, Wuon-Shik;Hwang, In-Kyoung;Choi, Hyoung-Min
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.2
    • /
    • pp.10-16
    • /
    • 2005
  • Because patients with coronary artery disease (CAD) have depressed vagal modulation and the mortality risk from acute myocardial infarction is lower in patients with higher vagal modulation, methods that can increase vagal modulation are desirable in patients with CAD. We intended to inspect the effect of recumbent posture on vagal modulation. By using angiography, 33 patients with abnormal (CAD group) and 33 patients with normal coronary arteries (control group) were studied. The nonlinear as well as the linear characteristics of heart rate variability (HRV) were analyzed on these patients in three recumbent postures: namely, the supine, right lateral decubitus, and left lateral decubitus postures. The lower the normalized high-frequency power (nHF) in the supine or left lateral decubitus posture, the higher the increase in the nHF when the posture was changed from supine or left lateral decubitus to right lateral decubitus in both groups of patients. Right lateral decubitus posture can lead to the highest vagal modulation and the lowest sympathetic modulation among the three recumbent postures in both normal and patients with CAD. Therefore, the right lateral decubitus posture can be used as an effective physiologic vagal enhancer in patients with CAD.

  • PDF

New Methodology to Develop Multi-parametric Measure of Heart Rate Variability Diagnosing Cardiovascular Disease

  • Jin, Seung-Hyun;Kim, Wuon-Shik;Park, Yong-Ki
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.2
    • /
    • pp.17-24
    • /
    • 2005
  • The main purpose of our study is to propose a new methodology to develop the multi-parametric measure including linear and nonlinear measures of heart rate variability diagnosing cardiovascular disease. We recorded electrocardiogram for three recumbent postures; the supine, left lateral, and right lateral postures. Twenty control subjects (age: $56.70{\pm}9.23$ years), 51 patients with angina pectoris (age: $59.98{\pm}8.41$ years) and 13 patients with acute coronary syndrome (age: $59.08{\pm}9.86$ years) participated in this study. To develop the multi-parametric measure of HRV, we used the multiple discriminant analysis method among statistical techniques. As a result, the multiple discriminant analysis gave 75.0% of goodness of fit. When the linear and nonlinear measures of HRV are individually used as a clinical tool to diagnose cardiac autonomic function, there is quite a possibility that the wrong results will be obtained due to each measure has different characteristics. Although our study is a preliminary one, we suggest that the multi-parametric measure, which takes into consideration the whole possible linear and nonlinear measures of HRV, may be helpful to diagnose the cardiovascular disease as a diagnostic supplementary tool.

  • PDF

Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function (무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현)

  • Lee, Sang-June;Kim, Myoung Nam;Lee, Jyung Hyun;Lim, Hyung-Gyu;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

Implementation of U-Healthcare System for Chronic Disease Management (만성 질환자 관리를 위한 U-Healthcare 시스템 구현)

  • Ryu, Geun-Teak;Choi, Hun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.233-240
    • /
    • 2014
  • According to the recent increasing trend of the ages, numbers of patients with chronic diseases are increasing and issues for health care are importantly emerged. In this thesis the research implements U-health care system for health care of patients with chronic diseases. The suggested system for health care of patients with chronic diseases composes bio measurement system, mobile gateway and medical information management server, and bio-signals are composed with modules such as electrocardiogram, blood pressure, blood sugar, oxygen saturation if configured as client. Blood sugar check was considered and implemented to be chosen the ways to transmit through bio measurement system or through gateway. Suggested bio measurement system and mobile gateway are transmitted through Bluetooth. The transmitted biodata is searched by observing health check through mobile gateway, by transmitting through network server, and by using client. By implementing bio signal observation system of patients with chronic diseases, present health check is available by monitoring measured bio data, and various bio signals are transmitted in the mobile environment.

Design of Computer Access Devices for Severly Motor-disability Using Bio-potentials (생체전위를 이용한 중증 운동장애자들을 위한 컴퓨터 접근제어장치 설계)

  • Jung, Sung-Jae;Kim, Myung-Dong;Park, Chan-Won;Kim, Il-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.11
    • /
    • pp.502-510
    • /
    • 2006
  • In this paper, we describe implementation of a computer access device for the severly motor-disability. Many people with severe motor disabilities need an augmentative communication technology. Those who are totally paralyzed, or 'locked-in' cannot use conventional augmentative technologies, all of which require some measure of muscle control. The forehead is often the last site to suffer degradation in cases of severe disability and degenerative disease. For example, In ALS(Amyotrophic Lateral Sclerosis) and MD(Muscular dystrophy) the ocular motorneurons and ocular muscles are usually spared permitting at least gross eye movements, but not precise eye pointing. We use brain and body forehead bio-potentials in a novel way to generate multiple signals for computer control inputs. A bio-amplifier within this device separates the forehead signal into three frequency channels. The lowest channel is responsive to bio-potentials resulting from an eye motion, and second channel is the band pass derived between 0.5 and 45Hz, falling within the accepted Electroencephalographic(EEG) range. A digital processing station subdivides this region into eleven components frequency bands using FFT algorithm. The third channel is defined as an Electromyographic(EMG) signal. It responds to contractions of facial muscles and is well suited to discrete on/off switch closures, keyboard commands. These signals are transmitted to a PC that analyzes in a time series and a frequency region and discriminates user's intentions. That software graphically displays user's bio-potential signals in the real time, therefore user can see their own bio-potentials and control their physiological signals little by little after some training sessions. As a result, we confirmed the performance and availability of the developed system with experimental user's bio-potentials.

Design and Implementation of a Readout Circuit for a Tactile Sensor Pad Based on Force Sensing Resistors (FSR로 구성된 촉각 센서 패드용 Readout 회로의 설계 및 구현)

  • Yoon, Seon-ho;Baek, Seung-hee;Kim, Cheong-worl
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.331-337
    • /
    • 2017
  • A readout circuit for a tactile sensor pad based on force sensing resistors was proposed, which was composed of an analog signal conditioning circuit and a digital circuit with a microcontroller. The conventional signal conditioning circuit has a dc offset voltage in the output signal, which results from the reference voltage applied to the FSR devices. The offset voltage reduces the dynamic range of the circuit and makes it difficult to operate the circuit under a low voltage power supply. In the proposed signal conditioning circuit, the dc offset voltage was removed completely. The microcontroller with A/D converter and D/A converter was used to enlarge the measurement range of pressure. For this, the microcontroller adjusts the FSR reference voltage according to the resistance magnitude of FSR under pressure. The operation of the proposed readout circuit which was connected to a tactile sensor pad with $5{\times}10$ FSR array was verified experimentally. The experimental results show the proposed readout circuit has the wider measurement range of pressure than the conventional circuit. The proposed circuit is suitable for low voltage and low power applications.

Signal Number Estimation Algorithm Based on Uniform Circular Array Antenna

  • Heui-Seon, Park;Hongrae, Kim;Suk-seung, Hwang
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2023
  • In modern wireless communication systems including beamformers or location-based services (LBS), which employ multiple antenna elements, estimating the number of signals is essential for accurately determining the quality of the communication service. Representative signal number estimation algorithms including the Akaike information criterion (AIC) and minimum description length (MDL) algorithms, which are information theoretical criterion models, determine the number of signals based on a reference value that minimizes each criterion. In general, increasing the number of elements mounted onto the array antenna enhances the performance of estimating the number of signals; however, it increases the computational complexity of the estimation algorithm. In addition, various configurations of array antennas for the increased number of antenna elements should be considered to efficiently utilize them in a limited location. In this paper, we introduce an efficient signal number estimation algorithm based on the beamspace based AIC and MDL techniques that reduce the computational complexity by reducing the dimension of a uniform circular array antenna. Since this algorithm is based on a uniform circular array antenna, it presents the advantages of a circular array antenna. The performance of the proposed signal number estimation algorithm is evaluated through computer simulation examples.