• Title/Summary/Keyword: Bio-signal Measurement

Search Result 160, Processing Time 0.027 seconds

Intelligent silicon bead chip design for bio-application (바이오 응용을 위한 지능형 실리콘 비드 칩 설계)

  • Moon, Hyung-Geun;Chung, In-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.999-1008
    • /
    • 2012
  • Unlike the existing CMOS chip, ISB (Intelligent Silicon Bead) is new concept biochip equipped with optical communication and memory function. It uses the light for power of SoC CMOS and interface with external devices therefore it is possible to miniaturize a chip size and lower the cost. This paper introduces an input protocol and a design of the low power and the low area to transfer the power and the signal through a single optical signal applied from external reader device to bead chip at the same time. It is also verified through simulation and measurement. In addition, low-power PROM is designed for recording and storing ID of a chip and it is successful in obtaining the value of output according to the optical input. Through this study, a new type biochip development can be expected by solving high cost and a limit of miniaturizing a chip area problem of an existing RFID.

Design a Portable Biomedical Signal Measuring System for U-Health (U-Health를 위한 휴대형 생체신호 측정 시스템 설계)

  • Lee, Han-Wook;Kim, Sung-Hoo;Jeong, Won-Geun;Lee, Ju-Won;Jang, Doo-Bong;Lee, Gun-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • U-Health is abbreviated from ubiquitous Health. Its final aim is "to improve the quality of life. To realize it, it is needed to generalize IT infrastructure such as the development of information-technology and construction of network. It is guaranteed to get medical care benefits unconsciously every time and everywhere based on this system. In this study, the environment of unconscious measurement was set up through ultra-violet instead of the existing Probe to wear with finger to follow this. TFT-LCD was included into module for display. U-Healthcare focused on the minimization and portable characteristic through the designed Zigbee communication module. Handled healthcare device was developed based on the U-Healthcare.

  • PDF

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

  • Kim, Younghak;Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1417-1427
    • /
    • 2019
  • In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant. The detection system consisted of a $20mm{\times}20mm{\times}5mm$ CZT crystal with $8{\times}8$ pixelated anodes and a common cathode, in addition to an application specific integrated circuit. The performance of the various radioisotopes $^{57}Co$, $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ was evaluated. In general, the amplitude of the induced signal in a CZT crystal depends on the interaction position and material non-uniformity. To minimize this dependency, a drift time correction was applied. The depth of each interaction was calculated by the drift time and the positional dependency of the signal amplitude was corrected based on the depth information. After the correction, the Compton regions of each spectrum were reduced, and energy resolutions of 122 keV, 356 keV, 511 keV, and 662 keV peaks were improved from 13.59%, 9.56%, 6.08%, and 5%-4.61%, 2.94%, 2.08%, and 2.2%, respectively. For the Compton imaging, simulations and experiments using one $^{137}Cs$ source with various angular positions and two $^{137}Cs$ sources were performed. Individual and multiple sources of $^{133}Ba$, $^{22}Na$, and $^{137}Cs$ were also measured. The images were successfully reconstructed by weighted list-mode maximum likelihood expectation maximization method. The angular resolutions and intrinsic efficiency of the $^{137}Cs$ experiments were approximately $7^{\circ}-9^{\circ}$ and $5{\times}10^{-4}-7{\times}10^{-4}$, respectively. The distortions of the source distribution were proportional to the offset angle.

Design and Evaluation of Blending Algorithm for Rate Adaptive Pace: Simulation Study (심박수 적응형 심박 조율 알고리즘 설계 및 평가: 시뮬레이션 연구)

  • Myoung, Hyoun-Seok;Lee, Kyoung Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.32-37
    • /
    • 2019
  • In this study, we designed a blending algorithm for rate adaptive pacing for cardiac pacemaker. Generally, rate adaptive pacing (RAP) is applied to patients whose heart rate does not rise during exercise for chronotropic incompetence (CI) patient. It is very important to develop an algorithm for RAP that can be properly applied to CI patients. In order to design an RAP algorithm we used dual sensors. Firstly, we designed a bio-signal measurement system based on the dual sensors, which are accelerometer and respiratory system. Secondly, we conducted treadmill test for the simulation experiment while using 3-lead ECG as reference. Finally, we designed a blending algorithm based on activation state of the dual sensors. The proposed blending algorithm was subdivided into three sections based on the accelerometer signal, which are rapidly increased section (W1), hardly changed section (W2), and decreased section (W3). Each weight is set aside for each section. To evaluate this algorithm, ten healthy adult males were participated. The correlation and Root Mean Square Error between the proposed algorithm and the reference were compared, and shown to be r=0.88 and 2.82 bpm, respectively. These results show that the proposed blending algorithm of dual sensors enables proper tracking of the heart rate during exercise. Also, it shows the possibility that the proposed blending algorithm can be applied to improve quality of life of the chronotropic incompetence patient.

Development of Acquisition System for Biological Signals using Raspberry Pi (라즈베리 파이를 이용한 생체신호 수집시스템 개발)

  • Yoo, Seunghoon;Kim, Sitae;Kim, Dongsoo;Lee, Younggun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.12
    • /
    • pp.1935-1941
    • /
    • 2021
  • In order to develop an algorithm using deep learning, which has been recently applied to various fields, it is necessary to have rich, high-quality learning data. In this paper, we propose an acquisition system for biological signals that simultaneously collects bio-signal data such as optical videos, thermal videos, and voices, which are mainly used in developing deep learning algorithms and useful in derivation of information, and transmit them to the server. To increase the portability of the collector, it was made based on Raspberry Pi, and the collected data is transmitted to the server through the wireless Internet. To enable simultaneous data collection from multiple collectors, an ID for login was assigned to each subject, and this was reflected in the database to facilitate data management. By presenting an example of biological data collection for fatigue measurement, we prove the application of the proposed acquisition system.

Usefulness of Functional MRI for the study of concentration sheet (Functional MRI를 이용한 학습집중력 향상 시트 개발)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2985-2989
    • /
    • 2009
  • An experiment was conducted to examine the effects of ceramic sheet on concentration of students studies. To demonstrate the improvement in the concentration of study, we obtained functional magnetic resonance imaging (fMRI), which has superior time resolution and measures brain noninvasively by using intrinsic contrast agent. As a result of Brainwave measurement, we could verify the blood flow's activate in the nearby frontal lobe related to memory process and noticeable ratio change in absolute alpha wave and beta wave after the analysis of Brainwave measurement. fMRI ascertains the physiological function of the brain and is being used to prevent the trouble medically that can be caused before and after the operation. For the visibility of cranial nerve network, many researches will be carried out to develope the product which is related to brain like concentration of study.

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

Adverse Effects on EEGs and Bio-Signals Coupling on Improving Machine Learning-Based Classification Performances

  • SuJin Bak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.10
    • /
    • pp.133-153
    • /
    • 2023
  • In this paper, we propose a novel approach to investigating brain-signal measurement technology using Electroencephalography (EEG). Traditionally, researchers have combined EEG signals with bio-signals (BSs) to enhance the classification performance of emotional states. Our objective was to explore the synergistic effects of coupling EEG and BSs, and determine whether the combination of EEG+BS improves the classification accuracy of emotional states compared to using EEG alone or combining EEG with pseudo-random signals (PS) generated arbitrarily by random generators. Employing four feature extraction methods, we examined four combinations: EEG alone, EG+BS, EEG+BS+PS, and EEG+PS, utilizing data from two widely-used open datasets. Emotional states (task versus rest states) were classified using Support Vector Machine (SVM) and Long Short-Term Memory (LSTM) classifiers. Our results revealed that when using the highest accuracy SVM-FFT, the average error rates of EEG+BS were 4.7% and 6.5% higher than those of EEG+PS and EEG alone, respectively. We also conducted a thorough analysis of EEG+BS by combining numerous PSs. The error rate of EEG+BS+PS displayed a V-shaped curve, initially decreasing due to the deep double descent phenomenon, followed by an increase attributed to the curse of dimensionality. Consequently, our findings suggest that the combination of EEG+BS may not always yield promising classification performance.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

A Design of a Reconfigurable 4th Order ΣΔ Modulator Using Two Op-amps (2개의 증폭기를 이용한 가변 구조 형의 4차 델타 시그마 변조기)

  • Yang, Su-Hun;Choi, Jeong-Hoon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.51-57
    • /
    • 2015
  • In this paper, in order to design the A / D converter with a high resolution of 14 bits or more for the biological signal processing, CMOS delta sigma modulator that is a 1.8V power supply voltage - were designed. we propose a new structure of The fourth order delta-sigma modulator that needs four op amps but we use only two op amps. By using a time -interleaving technique, we can re-construct the circuit and reuse the op amps. Also, we proposed a KT/C noise reduction circuit to reduce the thermal noise from a noisy resistor. We adjust the size of sampling capacitor between sampling time and integrating time, so we can reduce almost a half of KT/C noise. The measurement results of the chip is fabricated using a Magna 0.18um CMOS n-well1 poly 6 metal process. Power consumption is $828{\mu}W$ from a 1.8V supply voltage. The peak SNDR is measured as a 75.7dB and 81.3dB of DR at 1kHz input frequency and 256kHz sampling frequency. Measurement results show that KT/C noise reduction circuit enhance the 3dB of SNDR. FOM of the circuit is calculated to be 142dB and 41pJ / step.