• Title/Summary/Keyword: Bio-nano

Search Result 870, Processing Time 0.037 seconds

Theoretical Calculations of Infrared Bands of CH3+ and CH5+

  • Matin, Mohammad A.;Jang, Joonkyung;Park, Seung Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.2051-2055
    • /
    • 2013
  • Existing theoretical calculations predict that infrared spectra of the two most fundamental reactive carbo-ions, methyl cation $CH{_3}^+$ with $D_{3h}$ symmetry and protonated methyl cation $CH{_5}^+$ with $C_s(I)$, $C_s(II)$, and $C_{2v}$ symmetries, appear together in the 7-${\mu}m$ region corresponding to the C-H bending modes. Vibrational band profiles of $CH{_3}^+$ and $CH{_5}^+$ have been compared by ab initio calculation methods that use the basis sets of MP2/aug-cc-pVTZ and CCSD(T)/cc-pVTZ. Our results indicate that the bands of rotation-vibration transitions of $CH{_3}^+$ and $CH{_5}^+$ should overlap not only in the 3-${\mu}m$ region corresponding to the C-H stretching modes but also in the 7-${\mu}m$ region corresponding to the C-H bending modes. Five band intensities of $CH{_5}^+$ among fifteen vibrational transitions between 6 and 8 ${\mu}m$ region are stronger than those of the ${\nu}_2$ and ${\nu}_4$ bands in $CH{_3}^+$. Ultimate near degeneracy of the two bending vibrations ${\nu}_2$ and ${\nu}_4$ of $CH{_3}^+$along with the stronger intensities of $CH{_5}^+$ in the three hydrogen scrambling structures may cause extreme complications in the analysis of the high-resolution carbo-ion spectra in the 7-${\mu}m$ region.

Analysis of calcium phosphate nanoclusters using the TOF-MEIS

  • Jung, Kang-Won;Park, Jimin;Yang, Ki Dong;Nam, Ki Tae;Moon, DaeWon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.228.2-228.2
    • /
    • 2015
  • We have developed a TOF-MEIS system using 70~100 keV He+. A TOF-MEIS system was designed and constructed to minimize the ion beam damage effect by utilizing a pulsed ion beam with a pulse width < 1 ns and a TOF delay-line-detector with an 120 mm diameter and a time resolution of 180 ps. The TOF-MEIS is an useful tool for interfacial analysis of the composition and structure of nano and bio systems. Our recent applications are reported. We investigated the effect with Polyaspartic Acid (pAsp) and Osteocalcin on the initial bone growth of calcium hydroxyl appatite on a carboxyl terminated surface. When pAsp is not added to the self-assembled monolayers of Ca 2mM with Phosphate 1.2 mM, the growth procedure of calcium hydroxyl appatite cannot be monitored due to its rapid growth. When pAsp is added to the SAMs, the initial grow stage of the Ca-P can be monitored so that the chemical composition and their nucleus size can be analyzed. Firstly discovered the existence of 1-nm-sized abnormal calcium-rich clusters (Ca/P ~ 3) comprised of three calcium ions and one phosphate ion. First-principles studies demonstrated that the clusters can be stabilized through the passivation of the non-collagenous-protein mimicking carboxyl-ligands, and it progressively changes their compositional ratio toward that of a bulk phase (Ca/P~1.67) with a concurrent increase in their size to ~2 nm. Moreover, we found that the stoichiometry of the clusters and their growth behavior can be directed by the surrounding proteins, such as osteocalcin.

  • PDF

Influence of Deposition Method on Refractive Index of SiO2 and TiO2 Thin Films for Anti-reflective Multilayers

  • Song, Myung-Keun;Yang, Woo-Seok;Kwon, Soon-Woo;Song, Yo-Seung;Cho, Nam-Ihn;Lee, Deuk-Yong
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.9
    • /
    • pp.524-530
    • /
    • 2008
  • Anti-Reflective (AR) thin film coatings of $SiO_2$ (n= 1.48) and $TiO_2$ (n=2.17) were deposited by ion-beam assisted deposition (IBAD) with End-Hall ion source and conventional electron beam (e-beam) evaporation to investigate the effect of deposition method on the refractive indicies (n) of the fIlms. Green-light generation using a GaAs laser diode was achieved via excitation of the second harmonic. The latter resulted from the transmission of the fundamental guided-mode wave of 1064 nm through periodically poled $LiNbO_3$. Large differences in the refractive indicies of each of the layers in the multilayer coating may improve AR performance. IBAD of $SiO_2$ reduced its refractive index from 1.45 to 1.34 at 1064 nm. Conversely, e-beam evaporation of $TiO_2$ increased its refractive index from 1.80 to 2.11. In addition, no fluctuations in absorption at the wavelength of 1064 nm were found. The results suggest that films prepared by different deposition methods can increase the effectiveness of multilayer AR coatings.

Development of CMP process for reducing scratches during ILD CMP (ILD CMP중 Scratch 감소를 위한 CMP 공정기술 개발)

  • Kim, In-Gon;Kim, In-Kwon;Prasad, Y. Nagendra;Choi, Jea-Gon;Park, Jin-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.59-59
    • /
    • 2009
  • 현재 CMP분야는 광역 평탄화 반도체 소자의 집적화 및 소형화가 진행됨에 따라서 CMP 공정의 중요성은 날로 성장하고 있다. 하지만 이러한 CMP공정은 불가피하게도 scratch, pit, CMP residue와 같은 defect들을 발생시키고 있으며, 점점 선폭이 작아짐에 따라, 이러한 defect들이 반도체 수율에 미치는 영향은 심각해지고 있다. Defect들 중에 특히 scratch는 반도체에 치명적인 circuit failure를 일으키게 된다. 또한 반도체 내구성과 신뢰성을 감소시키게 되고, 누전전류를 증가시키는 등 바람직하지 못한 현상들이 생기게 된다. 본 연구에서는 scratch 와 같은 deflect들을 효율적으로 검출, 분석하고, scratch를 감소시키는데 그 목적이 있다. 본 실험을 위해 8" TEOS wafer와 commercial oxide slurry 및 friction polisher (Poli-500, G&P tech., Korea)를 사용하여 CMP 공정을 진행하였으며, CMP 공정조건은 각각 80rpm/80rpm/1psi(Platen speed/Head speed/Pressure)에서 1분 동안 연마를 한 후 scratch 발생 경향을 살펴보았다. CMP 후 wafer위에 오염되어 있는 slurry residue들을 제거하기 위해 SC-1, HF 세정을 이용하여 최적화된 post-CMP 공정기술을 제안하였다. Scratch 검출 및 분석을 위해 wafer surface analyzer (Surfscan 6200, Tencor, USA)와 optical microscope (LV100D, Nicon, Japan)를 사용하였다. CMP 공정 변수들에 따른 scratch 발생정도를 비교하였으며, scratch 발생 요인들에 따른 scratch 형태 및 발생정도를 살펴보았다. 최적화된 post-CMP 세정 조건은 메가소닉과 함께 SC-1 세정을 실시하여 slurry residue들을 제거한 후, HF 세정을 실시하여 잔여 오염물들을 제거하고 검출이 용이하도록 scratch를 확장시킬 수 있도록 제안하였으며, 100%의 particle removal efficiency (PRE)를 얻을 수 있었다. 실제 CMP 공정후 post-CMP 세정 단계별 scratch 개수를 측정한 결과, SC-1 세정 후 약 220개의 scratch가 검출되었으며, 검출되지 않았던 scratch가 HF 세정 후 확장되어 드러남에 따라 약 500개의 scratch 가 검출되었다.

  • PDF

Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry (네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출)

  • Boo, Han-Kil;Song, Youn-Joo;Park, Se-Jin;Chung, Taek-Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • Electrochemical behavior of fluoroquinolone antibacterial agents on carbon paste electrode (CPE) were investigated by cyclic voltammetry and square wave adsorptive stripping voltammetry. The fluoroquinolone antibacterial agents tested in this study were Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL) and Levofloxacin (LEV). In acetate buffer at pH 4.5, the oxidation peak potentials of the fluoroquinolone antibacterial agents of ENR, NOR, CIP, OFL, and LEV were 0.952 V, 1.052 V, 1.055 V, 0.983 V, and 0.990 V (vs. Ag/AgCl), respectively. And their oxidation peak currents from square wave adsorptive stripping voltammograms are proportional to the concentration of each antibacterial agent over the range from $0.2\;{\mu}M$ to $1\;{\mu}M$.

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

Development of a Rapid Diagnostic Test Kit to Detect IgG/IgM Antibody against Zika Virus Using Monoclonal Antibodies to the Envelope and Non-structural Protein 1 of the Virus

  • Kim, Yeong Hoon;Lee, Jihoo;Kim, Young-Eun;Chong, Chom-Kyu;Pinchemel, Yanaihara;Reisdorfer, Francis;Coelho, Joyce Brito;Dias, Ronaldo Ferreira;Bae, Pan Kee;Gusmao, Zuinara Pereira Maia;Ahn, Hye-Jin;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.1
    • /
    • pp.61-70
    • /
    • 2018
  • We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.

Properties of Nano Silver-Silica Composite according to Changing Molecular Weight of PVP (PVP 분자량 변화에 따른 은-실리카 나노복합체의 특성에 관한 연구)

  • Son, Eun-Jong;Hwang, Young-Gu;Shin, Yu-Shik;Jung, Gi-Hoon;Jung, Hae-Rim;Jeong, Sung-Hoon
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.55-55
    • /
    • 2011
  • 실리카 지지체 위에 은 (silver) 나노 입자를 부착시키는 방법으로는 지지체 표면을 먼저 은입자와 친화성이 큰 amino(-NH2), mercapto(-SH), cyan(-CN) 등의 관능기로 표면처리 하는 방법이 일반적으로 사용된다. 구체적으로 설명하면 첫 단계로 지지체인 실리카입자의 표면을 아민으로 표면 처리 한다. 실리카 입자위에 부착된 아민관능기는 입자 생성의 단계에서 은 (silver) 나노 입자가 붙는 접촉점의 역할과 핵 생성 장소로서의 역할을 하게되고, 아민 관능기의 이런 역할로 실리카 입자 표면에 부착된 핵이 생장하여 입자가 됨으로써 최종적으로 은(silver) 나노 입자가 실리카 지지체위에 부착된 형태의 나노복합체가 형성된다. 분자량이 다른 PVP를 사용하여 제조한, NH2와 SH로 계면처리 된 은-실리카 나노복합체제조를 시도하였다. 사용되는 PVP의 분자량이 증가함에 따라 긴 고분자 사슬에 의하여 생성된 입체장애가 증가하게 되어, 은 핵의 성장에 대한 물리적 장벽이 증가하게 된다. 그러므로 고정화된 은 입자의 크기가 감소하게 된다. 이러한 형상은 NH2기 또는 SH기로 계면 처리된 실리카를 이용하여 제조된 은-실리카 나노복합체 입자들에서 모두 관찰되지만, SH기로 계면처리된 실리카를 사용할 경우 고정화된 은 입자의 수가 더욱 많고, 크기 역시 더욱 균일함을 알 수 있다.

  • PDF

Graded Noise Elimination and Cluster Boundary Extraction in Confocal Sliced Images (공초점 단층 이미지에서 수준별 잡음제거와 클러스터 경계선 추출)

  • Cho, Mi-Gyung;Kim, Jin-Seok;Shim, Jae-Sool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.12
    • /
    • pp.2697-2704
    • /
    • 2011
  • In tissue engineering area, researchers observe symbiotic relationship such as proliferation, interaction, division apoptosis with time between cells in process of the 3D cell culture in hydrogels. The 3D cell culture process can be taken photographs into sliced images using confocal microscope. Symbiotic mechanism and changes of cell behaviors can be observed and analyzed from the images acquired by confocal microscope. In this paper, we proposed and developed graded noise elimination method and cluster boundary extraction method to extract boundaries information from sliced confocal images acquired in process of the 3D cell culture in hydrogels. The experiment based algorithm showed excellent performance for eliminating noises that have very small millet-shaped size. It is also showed to extract exact boundaries information for even complex clusters.

Development of Multiplex RT-PCR Assays for Rapid Detection and Subtyping of Influenza Type A Viruses from Clinical Specimens

  • Chang, Hee-Kyoung;Park, Jeung-Hyun;Song, Min-Suk;Oh, Taek-Kyu;Kim, Seok-Young;Kim, Chul-Jung;Kim, Hyung-Gee;Sung, Moon-Hee;Han, Heon-Seok;Hahn, Youn-Soo;Choi, Young-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1164-1169
    • /
    • 2008
  • We developed multiplex RT-PCR assays that can detect and identify 12 hemagglutinin (H1-H12) and 9 neuraminidase (N1-N9) subtypes that are commonly isolated from avian, swine, and human influenza A viruses. RT-PCR products with unique sizes characteristic of each subtype were amplified by multiplex RT-PCRs, and sequence analysis of each amplicon was demonstrated to be specific for each subtype with 24 reference viruses. The specificity was demonstrated further with DNA or cDNA templates from 7 viruses, 5 bacteria, and 50 influenza A virus-negative specimens. Furthermore, the assays could detect and subtype up to $10^5$ dilution of each of the reference viruses that had an original infectivity titer of $10^6\;EID_{50}/ml$. Of 188 virus isolates, the multiplex RT-PCR results agreed completely with individual RT-PCR subtyping results and with results obtained from virus isolations. Furthermore, the multiplex RT-PCR methods efficiently detected mixed infections with at least two different subtypes of influenza viruses in one host. Therefore, these methods could facilitate rapid and accurate subtyping of influenza A viruses directly from field specimens.