• Title/Summary/Keyword: Binocular vision function

Search Result 41, Processing Time 0.026 seconds

Relationship Between Subjective Symptoms with Near Work and Binocular Function (근업시 자각 증상과 양안시 기능의 관계)

  • Shin, Jin-Ah;Lee, Ok-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.125-130
    • /
    • 2007
  • The aim of this work was to study the relationship between subjective symptoms and binocular function during near work in forty one(12-17yr) schoolchildren. CISS symptom survey, amplitude of accommodation, accommodative facility, neagative relative accommodation(NRA)/positive relative accommodation(PRA) near point of convergence(NPC), heterophoria, AC/A ratios were measured. The results of measurement were compared with normal expected value of each test and classified into normal and abnormal group. Accommodative insufficiency was more general than convergence insufficiency and esophoria was greater than exophoria. NRA/PRA showed very high and AC/A ratios were very low compare with normal expected value. The results of CISS was as follows; most frequent symptom was tired, mean score was $16.63{\pm}7.49$, mean number of symptoms were $10.07{\pm}3.04$, and mean number of serious symptoms were $1.98{\pm}2.13$. After classified into 4 groups according to score of symptoms, number of symptoms, and degree of symptoms and then analyze the correlation compare with binocular vision test results. NRA was most correlated with group comparison, accommodative facility was most correlated with score of symptoms, NRA was most correlated with number of symptoms, and near horizontal phorias were most correlated with serious symptoms. NRA showed most correlative relation with near symptoms.

  • PDF

Change of Binocular Vision Induced by Longitudinal Chromatic Aberration during Near Work (근거리 작업 시 종색수차에 따른 양안시의 변화)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.219-228
    • /
    • 2015
  • Purpose: The current study was performed to compare the difference in binocular visual function depending on variable background colors at near work. Method: Fifty four adults (18 males, 34 females) who consented to the present study and had no ocular disease, ocular surgery history, strabismus and amblyopia with normal binocular vision were participated into this study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min. Then, their heterophoria, AC/A ratio, near point of convergence, accommodation facility, relative accommodation and vergence were measured before and after reading. The difference of measurements were compared. Result: Overall heterophoria was tended to decrease with regardless of background color. AC/A ratio showed a tendency of increase after reading the novels with all backgrounds except white background. Near point of convergence was significantly increased compared to before reading at all background color. Accommodative facility of dominant and non-dominant eyes were also significantly increased after reading however, binocular accommodative facility showed a tendency of decrease. Negative relative accommodation also decreased at all background colors however, the change of positive relative accommodation was not significantly different. In case of vergence, there was significant difference in break point of far BO and recovery point of far BI by the wavelength of background color. Conclusions: From the results, it was known there is convergence change depending on the wavelength of light even though same amount of accommodation and convergence is required when doing near work for certain period. Thus, it can be suggested that the adjustment of the near working environment which perception of various color was required, should be conducted according to the main wavelength.

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

An Application of Active Vision Head Control Using Model-based Compensating Neural Networks Controller

  • Kim, Kyung-Hwan;Keigo, Watanabe
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.168.1-168
    • /
    • 2001
  • This article describes a novel model-based compensating neural network (NN) model developed to be used in our active binocular head controller, which addresses both the kinematics and dynamics aspects in trying to precisely track a moving object of interest to keep it in view. The compensating NN model is constructed using two classes of self-tuning neural models: namely Neural Gas (NG) algorithm and SoftMax function networks. The resultant servo controller is shown to be able to handle the tracking problem with a minimum knowledge of the dynamic aspects of the system.

  • PDF

Effect of Artificially Decreased Visual Acuity upon Eye-Hand Coordination using Lee-Ryan Eye-Hand Coordination Test (Lee-Ryan Eye-Hand Coordination Test를 이용한 인위적 시력저하가 눈-손 협응능력에 미치는 영향)

  • Lee, Ki-Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.371-376
    • /
    • 2014
  • Purpose: The aim of this study was to explore the effect of artificially decreased eye in normal vision on eye-hand coordination (EHC) when using the Lee-Ryan Eye-Hand Coordination Test recently reported. Methods: Eleven adults with normal vision aged $29.46{\pm}5.94$ years participated for this study where a non-dominant eye artificially induced moderate refractive amblyopic vision at near by adding a plus lens conducted EHC tasks and then did the test again under normal vision following 2 weeks. To investigate the ability of EHC, 7 tasks including individually different level of difficulty in the Lee-Ryan EHC Test were selected to compare and analyze EHC in terms of two independent variables such as time taken and the number of errors. Results: In time taken, subjects with artificially decreased vision took more time than normal vision under monocular conditions (p=0.013), while those with the decreased vision completed their tasks faster than normal vision under binocular conditions (p=0.001). In the number of errors, subjects with the decreased vision made more mistakes (p<0.001) as shown in time taken, whereas there was no difference between monocular and binocular viewing conditions in the decreased vision. Conclusions: Unlike previous EHC tests including limitations for application, deficit in EHC can be screened by the Lee-Ryan EHC Test developed based on simple computer-based system. Therefore, it is considered that further studies relevant to deficits in visual function such as amblyopia will be carried out in clinics as well as research.

The Analysis of Binocular Vision Function by measuring Accommodative Convergence(AC/A) (조절성 폭주비(AC/A) 측정에 의한 양안시 기능 분석)

  • Kang, In-San;Seo, Yong-Won;Choi, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.159-164
    • /
    • 2005
  • Accommodation and convergence is combination movement which is closely connected with each other. When one of them is stimulated, both of functions occur at the same time. Specially, the convergence by the accommodation's stimulation is called as accommodative convergence. That has excess or deficiency according to refraction state of eye. This study was performed by using both of Gradient method and Heterophoria method to 41 adults who have no any ophthalmic disease. 1. As the result of investigation about the distribution of heterophoria at distance, there were orthophoria of 5 subjects, exophoria of 32 and esophoria of 4. Exoporia occupied at the hightest rate. The distribution of heterophoria at near cover a wider range more than at distance. 2. When we measured the horizontal heterophoria amount in the state of relaxation of accommodation power of lens, exophoria amount increased in case of 38 subjects. 3. The person who has $4{\sim}6{\Delta}/D$ which conform to normal AC/A ratio occupied 27 subjects(66%) in Heterophoria method and 16(39%) in Gradient method, respectively.

  • PDF

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

The study of binocular function of college students (대학생들의 시기능에 대한 연구)

  • Cho, Young-Rae;Park, Hyun-Ju;Seo, Ji-Keun;Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • Binocular vision had a short history in Korea. As there were many near works in these days, the needs about comparative study have been increased. There was related to both refractive error and binocular anomalies, but it is difficult to applying for binocular vision expected findings in itself due to the fact that Korean differ from foreigner. Objects were 100 adults in 18-36 years old ages, The test was Von Gaefe method and used aparatus was phoropter(Shinnippon VT10)and visual chart(Shinnippon CT30). According to interview results was that symptom in near works were headaches 28.0%, blinking 27.3%, red eye 25.1%, eyepain 15.6%, watering 15.3%, itch 12.2%, photophobia 8.5% and eye strain 7.4%. A people who have above ${\pm}0.50$ D refractive error in total objectives (100-male 45/female 55) were classified into ametropia. There was a results such as emmetropia (12.0%), ametropia(88.0%), exophoria(32.0%), esophoria(12.0%). Far negative relative convergence were that in case of high 43.0%, in case of low 7.0%. Far positive relative convergence were that in case of high 15.0%, in case of low 38.0%. Near phoria was exophoria(32.0%), esophoria(12.0%). Near negative relative convergence were that in case of high 23.0%, in case of low 38.0%. Far positive relative convergence were that in case of high 29.0%, in case of low 23.0%. Near negative relative accommodation were that in case of high 10.0%, in case of low 14,0%, Far positive relative convergence were that in case of high 69.0%, in case of low 12.0%. Results were different from expected findings, and especially positive relative accommodation was very high, However, We suggest that the expected findings in Korea for several subjects must study in binocular function.

  • PDF

The Change After Visual Training of Forced Vergence Fixation Disparity Curve (강제vergence 주시시차곡선의 시기능훈련 후의 변화)

  • Choi, Sun-Mi;Lee, Ki-Young;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.539-550
    • /
    • 2014
  • Purpose: This research was designed to figure out if there are changes based on types of vergence fixation disparity curve after optical correction and vision training to for people with steep slope of forced vergence fixation disparity curve and symptoms. Methods: For 30 subjects out of 91 subjects, who have steep slopes of fixation disparity curve examined with Wesson Fixation Disparity Card and symptoms about steep slope of fixation disparity curve, proper vision training was offered for 5 weeks. Results: After Vision training for 30 people with the symptoms of type I, II, III, IV for 5 weeks, slope of fixation disparity curve was significantly changed (p=0.013), and the results of binocular vision test and subjective symptoms were also significantly improved. Conclusions: Vision training can not only affect the change of fixation disparity curve, but also relieve the symptoms. Fixation disparity curve has lots of visual function information of the subject and can be suggested as a guideline for prescribing.

Research on Visual Function Before and After Prescription of Vertical Prism (수직사위 교정 전·후 시기능 변화에 대한 연구)

  • Kim, So-ra;Lee, Gi-yung;Park, Hyun-ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.229-235
    • /
    • 2015
  • Purpose: This study was undertaken to study on visual function before and after prescription of vertical prism. Methods: 80 subjects (10-30ages) who had been precribed vertical prism and 1 year after they were represcribed vertical prism. Results: Phoria (p=0.000), supra vergence (p=0.000), NPC (p=0.003), NPA (right eye) (p=0.005), NPA(left eye) (p=0.000) showed a significant change. Conclusion: Vertical prism prescription was reduced during revisit. Supra vergence, NPC, NPA(right eye), NPA(left eye) showed a significant change. Binocular Accommodative lag was not associated with vertical prism prescription and binocular vision findings.