• 제목/요약/키워드: Bilge

검색결과 109건 처리시간 0.025초

Comparison of two different methods of detecting residual caries

  • Vural, Uzay Koc;Kutuk, Zeynep Bilge;Ergin, Esra;Cakir, Filiz Yalcin;Gurgan, Sevil
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.48-53
    • /
    • 2017
  • Objectives: The aim of this study was to investigate the ability of the fluorescence-aided caries excavation (FACE) device to detect residual caries by comparing conventional methods in vivo. Materials and Methods: A total of 301 females and 202 males with carious teeth participated in this study. The cavity preparations were done by grade 4 (Group 1, 154 teeth), grade 5 (Group 2, 176 teeth), and postgraduate (Group 3, 173 teeth) students. After caries excavation using a handpiece and hand instruments, the presence of residual caries was evaluated by 2 investigators who were previously calibrated for visual-tactile assessment with and without magnifying glasses and trained in the use of a FACE device. The tooth number, cavity type, and presence or absence of residual caries were recorded. The data were analyzed using the Chi-square test, the Fisher's Exact test, or the McNemar test as appropriate. Kappa statistics was used for calibration. In all tests, the level of significance was set at p = 0.05. Results: Almost half of the cavities prepared were Class II (Class I, 20.9%; Class II, 48.9%; Class III, 20.1%; Class IV, 3.4%; Class V, 6.8%). Higher numbers of cavities left with caries were observed in Groups 1 and 2 than in Group 3 for all examination methods. Significant differences were found between visual inspection with or without magnifying glasses and inspection with a FACE device for all groups (p < 0.001). More residual caries were detected through inspection with a FACE device (46.5%) than through either visual inspection (31.8%) or inspection with a magnifying glass (37.6%). Conclusions: Within the limitations of this study, the FACE device may be an effective method for the detection of residual caries.

In vitro evaluation of color and translucency reproduction of maxillofacial prostheses using a computerized system

  • Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Bagkur, Meral;Bal, Bilge Turhan;Arici, Yeliz Kasko
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.422-429
    • /
    • 2018
  • PURPOSE. Accurate color matching of maxillofacial prostheses to skin is important for esthetics. A computerized color matching system specific to human skin has recently been developed. The purpose of this study was to evaluate the accuracy in color and translucency matching of the computerized color matching system across different skin colors. MATERIALS AND METHODS. The silicone was colored to simulate 28 different skin colors (n=5) to serve as "target skin colors". Using a spectrocolorometer (e-skin), color codes were determined for "replicate skin color" fabrication. CIELAB Delta-E between target skin color-replicate skin color pairs and translucency parameter were calculated. CIELAB Delta-E values were compared with one-way ANOVA and Tukey multiple-comparison. The agreement between $L^*$, $a^*$, $b^*$ and translucency parameter of target skin colors and replicate skin color were calculated by a two-way mixed average measures intraclass correlation coefficient. Translucency parameter of target skin color- replicate skin color pairs were compared with Paired t-test (${\alpha}=.05$). RESULTS. The mean CIELAB Delta-E value was 3.83 and significant differences were found among colors. The intraclass correlation coefficient showed excellent reliability for $L^*$, $a^*$, $b^*$ and good reliability for translucency parameter (P<.001). The mean translucency parameter of replicate skin colors was significantly higher than that of translucency parameter. CONCLUSION. The computerized color matching system specific to human skin was found to be reliable in terms of color and translucency between target skin colors and replicate skin color.

중앙 단면 형상에 따른 횡동요 감쇠 추정 실험 연구 (Experimental Study on Estimation of Roll Damping for Various Midship Sections)

  • 박병원;정동우;정재상;박인보;조석규;성홍근
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.322-329
    • /
    • 2019
  • The magnitude of the roll motion of a floating structure depends on the roll damping acting on the body. In other words, the roll damping of a floating structure must be accurately obtained in order to precisely evaluate the roll motion. Various methods are used to evaluate the roll damping of a floating structure, such as the linear potential theory, computational fluid dynamics (CFD), and model tests. However, it is difficult to evaluate the roll motion of a floating structure with appendages such as a bilge keel and riser slot due to the limitation of ignoring the viscous effects in the linear potential theory. Among these methods, a model test based on a free decay test and harmonic excited roll motion (HERM) is known to be the most reliable method to estimate the roll damping of the floating structures. In this study, model tests using free decay and HERM techniques were performed in the Ocean Engineering Basin (OEB) of KRISO with various types of midship sections. The roll damping results were estimated based on post-processing methods using both techniques, and the roll damping results were compared.

The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material

  • Akbulut, Makbule Bilge;Bozkurt, Durmus Alperen;Terlemez, Arslan;Akman, Melek
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). Materials and Methods: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at $37^{\circ}C$ for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. Results: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. Conclusions: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.

Body Surface Area Is Not a Reliable Predictor of Tracheal Tube Size in Children

  • Uzumcugil, Filiz;Celebioglu, Emre Can;Ozkaragoz, Demet Basak;Yilbas, Aysun Ankay;Akca, Basak;Lotfinagsh, Nazgol;Celebioglu, Bilge
    • Clinical and Experimental Otorhinolaryngology
    • /
    • 제11권4호
    • /
    • pp.301-308
    • /
    • 2018
  • Objectives. The age-based Cole formula has been employed for the estimation of endotracheal tube (ETT) size due to its ease of use, but may not appropriately consider growth rates among children. Child growth is assessed by calculating the body surface area (BSA). The association between the outer diameter of an appropriate uncuffed-endotracheal-tube (ETT-OD) and the BSA values of patients at 24-96 months of age was our primary outcome. Methods. Cole formula, BSA, age, height, weight and ultrasound measurement of subglottic-transverse-diameter were evaluated for correlations with correct uncuffed ETT-OD. The Cole formula, BSA, and ultrasound measurements were analyzed for estimation rates in all patients and age subgroups. The maximum allowed error for the estimation of ETT-OD was ${\leq}0.3mm$. Patients' tracheas were intubated with tubes chosen by Cole formula and correct ETT-OD values were determined using leak test. ETT exchange rates were recorded. Results. One-hundred twenty-seven patients were analyzed for the determination of estimation rates. Thirteen patients aged ${\geq}72months$ were intubated with cuffed ETT-OD of 8.4 mm and were accepted to need uncuffed ETT-OD >8.4 mm in order to be included in estimation rates, but excluded from correlations for size analysis. One-hundred fourteen patients were analyzed for correlations between correct ETT-OD (determined by the leak test) and outcome parameters. Cole formula, ultrasonography, and BSA had similar correct estimation rates. All three parameters had higher underestimation rates as age increased. Conclusion. The Cole formula, BSA, and ultrasonography had similar estimation rates in patients aged ${\geq}24$ to ${\leq}96months$. BSA had a correct estimation rate of 40.2% and may not be reliable in clinical practice to predict uncuffed-ETT-size.

The Relationship of Leptin (+19) AG, Leptin (2548) GA, and Leptin Receptor Gln223Arg Gene Polymorphisms with Obesity and Metabolic Syndrome in Obese Children and Adolescents

  • Bilge, Serap;Yilmaz, Resul;Karaslan, Erhan;Ozer, Samet;Ates, Omer;Ensari, Emel;Demir, Osman
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제24권3호
    • /
    • pp.306-315
    • /
    • 2021
  • Purpose: Obesity is defined as the abnormal or excessive accumulation of fat over acceptable limits. Leptin is a metabolic hormone present in the circulation in amounts proportional to fat mass. Leptin reduces food intake and increases energy expenditure, thus regulating body weight and homeostasis. Various polymorphisms are present in the leptin gene and its receptor. These polymorphisms may be associated with obesity. This study aimed to show the association of leptin (+19) AG, leptin (2548) GA, and Gln223Arg leptin receptor polymorphisms with obesity and metabolic syndrome in Turkish children aged 6-17 years, and to conduct further investigations regarding the genetic etiology of obesity. Methods: A total of 174 patients diagnosed with obesity and 150 healthy children who were treated at Tokat Gaziosmanpasa Medical School Hospital between September 2014 and March 2015 were included in this study. The ages of the children were between 6 and 17 years, and anthropometric and laboratory results were recorded. Genotyping of leptin (+19) AG, leptin (2548) GA, and leptin receptor Gln223Arg polymorphisms was performed by polymerase chain reaction. Results: An association between leptin receptor Gln223Arg gene polymorphism and obesity was detected. Conclusion: Further studies are needed to determine the role of genetic etiologies and to indicate the role of leptin signal transmission impairment in the pathogenesis of obesity. We hope that gene therapy can soon provide a solution for obesity.

Effects of feed intake and water hardness on fluralaner pharmacokinetics in layer chickens

  • Sari, Ataman Bilge;Gunes, Yigit;Anlas, Ceren;Alkan, Fulya Ustun;Guncum, Enes;Ustuner, Oya;Bakirel, Tulay
    • Journal of Veterinary Science
    • /
    • 제23권5호
    • /
    • pp.64.1-64.9
    • /
    • 2022
  • Background: Fluralaner is a novel drug belonging to the isoxazoline class that acts on external parasites of domestic animals. It is used systemically via drinking water, especially against red poultry mite in layer chickens. Fluralaner is frequently used in layers infected with D. gallinae. However, no study to date has investigated the effects of feed intake and water hardness. Objectives: This study aimed to investigate the effects of variable water hardness and feed intake on the pharmacokinetic profile of fluralaner. Methods: Layer chickens were divided into four groups (n = 8): fed + purified water (Group 1), feed restricted + purified water (Group 2), feed restricted + hard water (Group 3), and feed restricted + soft water (Group 4). After administering a single dose of the drug with drinking water, the blood samples were collected for 21 days. Fluralaner concentrations in plasma samples were determined by liquid chromatography/tandem mass spectrometry. The maximum plasma concentration (Cmax), time to reach maximum plasma concentration (tmax), area under the concentration-time curve values (AUC0-21d), half-life (t1/2), and other pharmacokinetic parameters were calculated. Results: Although the highest maximum plasma concentration (Cmax) was determined in Group 1 (fed + purified water), no statistically significant difference was found in the Cmax, tmax, t1/2, MRT0-inf_obs, Vz/Fobs, and Cl/F_obs parameters between the experimental groups. Conclusions: It was concluded that the feed intake or water hardness did not change the pharmacokinetic profile of fluralaner in layer chickens. Therefore, fluralaner could be used before or after feeding with the varying water hardness in poultry industry.

The effects of cement thickness and cement shade on the final color of lithium disilicate crowns

  • Yigit Yamali;Merve Bankoglu Gungor;Secil Karakoca Nemli;Bilge Turhan Bal
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권2호
    • /
    • pp.93-100
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the effect of resin cement color, cement thickness, and thermocycling on the final color of monolithic lithium disilicate crowns. MATERIALS AND METHODS. A total of ninety prepared central incisors of typodont teeth were restored with lithium disilicate crowns which have different cement thicknesses (40 ㎛, 80 ㎛, and 120 ㎛) and cement shades (clear, yellow, and white). Color parameters of restorations were measured with a spectrophotometer in three different steps 1) before cementing 2) after cementing and 3) after thermocycling with 10000 cycles. Color differences (ΔE00) were calculated with the CIEDE2000 formula and evaluated according to perceptibility (0.8) and acceptability (1.8) thresholds. The ΔE00 data were analyzed by using two-way ANOVA before and after thermocycling (α = .05). RESULTS. There was no interaction between the cement shade and the cement thickness factors. After cementation, the mean ΔE00 was under the perceptibility threshold in the group of 40 ㎛ cement thickness and clear cement while it was between the perceptibility and acceptability thresholds (0.8 < ΔE00 < 1.8) for all other groups. After thermocycling, the ΔE00 values were between the perceptibility and acceptability thresholds for all experimental groups. Although there were no significant differences among the groups, thermocycling increased the color difference values. CONCLUSION. The cementation of restorations with clear, yellow, and white resin cements resulted in color differences with uncemented restorations except for the group cemented with clear cement in 40 ㎛ cement thickness. All study groups revealed perceptible color change after thermocycling.

Pregnant women's knowledge about and beliefs toward COVID-19 vaccine: a cross-sectional study

  • Osman Samet Gunkaya;Arzu Bilge Tekin;Murat Yassa;Oguz Arslan;Kubra Karakoc;Nesibe Demirtas;Canberk Usta;Cigdem Kunt Isguder;Niyazi Tug
    • Clinical and Experimental Vaccine Research
    • /
    • 제12권2호
    • /
    • pp.134-142
    • /
    • 2023
  • Purpose: The aim of this study was to determine the scope of knowledge, attitudes, and behaviors of pregnant women about the coronavirus disease 2019 (COVID-19) vaccine. Materials and Methods: A total of 886 pregnant women were recruited for the study. A cross-sectional questionnaire was conducted on these selected participants. Data about past infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), SARS-CoV-2 infection of closely related people, and deaths due to COVID-19 among their relatives were questioned. Results: The rate of vaccination was higher (64.1%) in pregnant women with higher education levels. Informing about the vaccine, especially by health professionals, showed that the rates of vaccination (25%) increased (p<0.001). In addition, a significant increase was observed in vaccination rates with increasing age and financial income (p<0.001). Conclusion: The main limitation of our study is that the vaccine, which was approved for "emergency use", was just started to be administered to pregnant women during the study. Our findings show that our target audience, low-income, low-education, younger pregnant women should be given more attention than those who apply to the doctor for routine follow-up.

콴다효과를 적용한 고정식 핀 안정기의 성능개선에 관한 연구 (A Study to Improve the Performance of a Fixd Type Fin Stabilizer with Coanda Effect)

  • 서대원;이세진;이승희
    • 한국항해항만학회지
    • /
    • 제37권3호
    • /
    • pp.257-262
    • /
    • 2013
  • 거친 바다를 운항하는 선박의 경우 횡 동요로 인해 선박 내의 장비운영 문제 및 탑승객들에게 큰 불편함을 초래한다. 따라서 횡동요 감쇠를 위한 목적으로 빌지 킬, 핀 안정기, 자이로스코프, ART(Anti-Rolling Tank), 타, 플랩 등 다양한 횡 동요 감쇠장치들이 사용되고 있다. 콴다효과는 콴다제트가 곡면의 표면을 따라 흐르며 주위 유동의 순환을 증가시켜 양력을 효과적으로 발생시키는 방법으로 핀의 양력성능을 향상시킬 수 있다. 본 연구에서는 모형시험 및 수치계산을 통해 콴다효과를 적용한 고정식 핀 안정기의 사용가능성을 검토하였다. 그 결과 받음각이 $0^{\circ}$에서, 제트모멘텀을 $C_j$ = 0.25 만큼 공급할 때, 기준 핀의 최대 작동각($26^{\circ}$)에서 발생되는 양력과 동일하게 발생되는 것으로 나타났다. 즉 받음각을 변화시키는 기존의 핀 안정기와 달리 받음각을 고정하고, 콴다효과를 통한 제트유동제어만으로 선박의 횡 동요를 능동적으로 제어 할 수 있을 것으로 보인다.