도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구- (Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves-)

  • 진성훈;서경필
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향 (The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves)

  • 이계한;서종천
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 1998
  • 판막 후부의 공동부는 판막의 닫힘 거동과 판막 주위의 혈류 유동장을 변화시켜 인공 판막의 수력학적 성능에 영향을 미칠 수 있다. 계식 이엽 판막(SJMV), 폴리머 단엽 판막(MLPV), 폴리머 삼엽 판막(FTPV)을 판막 후부에 공동부가 있는 시험부와 공동부가 없는 직관형 시험부에 설치하여 모의 순환 장치에서 판막의 수력학적 성능을 평가하였다. 판막의 누수량은 공동부가 있는 시험부에서 약간 작았고, 수축기 평균 압력강하는 크게 나타났으나 통계적으로는 큰 차이가 없었다. 따라서 판막 후부의 공동부는 판막의 수력학적 성능에 큰 영향을 나타내지 않았다. 유량 파형의 해석 결과 판막 후부 공동부는 MLPV에서는 판막의 닫힘에 큰 영향을 주지 않았으나, SJMV에서는 판막의 닫힘이 일찍 시작하게 하였고 이 영향은 FTPV에서 더욱 크게 나타났다. FTPV는 공동부가 있는 시험부에서 역류 최대 유량이 감소하였으므로 판막 후두에 공동부는 판막의 급격한 닫힘에 의한 역류 제트의 발생을 감소시키리라 기대된다.

  • PDF

ATS 인공 심장 판막의 단기 및 중기 임상성적 (Short and Intermediate Term Results of the ATS Heart Valve Replacement)

  • 임창영;문승철;양진영;구원모;김대식;이건;이헌재
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석 (Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves)

  • 정성철;김미정;송창민;김우식;신용철;김병열
    • Journal of Chest Surgery
    • /
    • 제41권4호
    • /
    • pp.430-438
    • /
    • 2008
  • 배경: 기계 심장판막 대치술 후 발생하는 혈전성 합병증을 방지하기 위해 항응고제 치료로써 와파린을 환자에게 투여한다. 이때 환자에 따른 적절한 와파린 용량을 결정하기 위한 지표로서 INR을 참고하는데 통상 대동맥판막은 $2.0{\sim}3.0$, 승모판막은 $2.5{\sim}3.5$가 참고치로서 받아들여지고 있다. 하지만 임상 경험상 대부분의 환자에서 이 수치로 유지하였을때 출혈성 합병증(비출혈, 혈뇨, 자궁출혈, 뇌출혈 등)이 빈번하게 발생하여 참고치보다 더 낮게 유지하는 경우가 많다. 이에 본원에서는 기계 심장판막 환자들을 후향적으로 조사하여 혈전성 합병증의 빈도가 낮은 적정한 INR을 알아보고자 한다. 대상 및 방법: 1984년 1월부터 2007년 2월까지 이엽성 기계 심장판막 대치술을 받고 생존한 311명의 환자를 대상으로 후향적으로 조사하였다. 대동맥판막치환 환자들(60명)은 INR $1.5{\sim}2.0$ (1군), $2.0{\sim}2.5$ (2군), 2.5 (3군) 이상의 세 군으로 나누고 승모판막치환(171명)이나 승모판막과 대동맥판막을 동시에 치환한 환자들(80명)은 INR $1.5{\sim}2.0$ (1군), $2.0{\sim}2.5$ (2군), $2.5{\sim}3.0$ (3군), 3.0 (4군) 이상의 네군으로 나누어 혈전성 합병증 발생률, 중요출혈성합병증 발생률을 조사하여 각각의 생존함수를 비교하였다. 결과: 대동맥 판막치환 환자 중 혈전성 합병증은 2명, 출혈성합병증은 4명이 발생하였고 세군의 혈전성 합병증의 생존함수의 차이는 관찰되지 않았고 출혈성 합병증의 생존곡선에서 1, 2군과 3군의 차이가 관찰되었다. 승모판막치환이나 승모판막과 대동맥판막을 동시에 치환한 환자들 중 혈전성 합병증은 13명, 출혈성 합병증은 15명이 발생하였고 네 군의 혈전성 합병증의 생존함수의 차이는 관찰되지 않았고 출혈성 합병증은 1, 2군과 3, 4군에서 차이를 보였다. 결론: 모든 판막에서 INR이 $1.5{\sim}2.5$ (1군과 2군)로 유지한 환자들이 그 이상으로 유지한 환자들보다 혈전성 합병증에서 차이를 보이지 않았고 출혈성 합병증에서 유의하게 감소하는 양상을 보여 이엽성 기계판막에서 적정한 INR은 $1.5{\sim}2.5$로 유지하는 것이 바람직하다고 판단된다.

St.Jude 기계판막을 이용한 인공심장판막 치환의 외과적 고찰 (Clinical Evaluation of St.Jude Medical Valve Replacement)

  • 진웅;나석주;조규도;김치경;조건현;왕영필;이선희;곽문섭;김세화;이홍균
    • Journal of Chest Surgery
    • /
    • 제27권4호
    • /
    • pp.272-280
    • /
    • 1994
  • Total 400 St.Jude Medical Bileaflet Valves were implanted in 336 pts from January 1983 to June 1993; 64 were aortic, 205 were mitral, 64 were double valve and 3 were tricuspid position. The follow up period extended from 6 months to 10 years[mean 24.3 months]. Male to female ratio was 1:1.7. There were total 27 deaths[cardiac related 20, cardiac non-related 7]. Overall mortality was 2.9%/pt-yr. There were 10 early deaths[3.0%] and 10 late cardiac related deaths [3.0%]. Prosthetic valve related complications occurred in 19 patients[5.7%] and among them, seven died; four died of thromboembolic events, two died of anticoagulants therapy related hemorrhagic complications and one died of bacterial endocarditis. NYHA class improved significantly especially in aortic valve replacement and double valve replacement. In AVR cases, the mean NYHA was 2.8 preoperatively and 1.3 postoperatively. And in DVR cases, 3.3 preoperatively and 2.2 postoperatively. The decision to employ a particular prosthesis was made according to the anticipated or known complications of the valve. The St.Jude Medical Valve retains all the hazards of other mechanical valves, most notably, thromboembolism. But the hemodynamic performance of St.Jude Medical Valve compared most favorably with other substitute valves in many reports. 0ur experience didn`t show any differences compared other authors in terms of valve related complication. So we concluded St. Jude Medical Valve can be primarily considered in the selection of artificial valve except in the patients when the usage of anticoagulant therapy is contraindicated.

  • PDF

On-X 기계판막을 이용한 판막치환술의 단기성적분석 (Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • 제37권9호
    • /
    • pp.742-748
    • /
    • 2004
  • On-X 판막은 비교적 최근 소개된 이엽성 기계판막으로 국립의료원에서 시행한 28명의 환자의 단기 임상성적을 통하여 판막의 안정성과 유용성을 보고하고자 한다. 대상 및 방법: 1999년 5월부터 2003년 5월까지 On-X 판막을 이용하여 32예의 판막치환술을 받은 28명의 연속적인 환자를 대상으로 하였으며 승모판막 치환 12예, 대동맥 판막치환 10예 그리고 승모판막 및 대동맥판막치환 6예이었다. 수술 후 발생한 합병증 및 사망률에 대한 정의 및 분류는 심장 판막수술에 대한 AATS/STS 지침에 근거하여 분석하였다. 전체 추적기간은 64환자-년이었고 평균 27개월이었다 결과: 수술 후 30일 이내의 조기 사망률은 7.14% (2/28)이었으며 만기사망은 없었다. 2년 생존율은 전체적으로 92.86$\pm$4.87% 이며 대동맥판막치환술이 90$\pm$9.49%, 이중판막치환술이 83.3$\pm$1.52%, 승모판막치환술이 100%로 나타났다. 혈전 색전증이 가장 많은 합병증으로 2예가 있었으며 모두 승모판막치환 증례에서 발생되어 Linearized Ratio는 총 3.17%/환자-년이었으며 승모판막만을 보면 6.5%/환자-년이었고 항응고제와 관련 된 출혈, 판막폐쇄증, 판막주위누출, 심내막염 등의 합병증의 모든 예에서 발생되지 않아 판막관련 합병증이 없는 2년간의 빈도는 84.85 $\pm$ 10.75% (freedom from valve related complication)이었다. 수술전 NYHA Class III 이상인 증례가 24예(85.71%)이었으나 수술 후에는 NYHA Class I 또는 II에 속하는 증례가 25예로 89.29%를 보였다. 용혈척도로서 혈색소 수치, 혈장 LDH, 망상적혈구수치, 간접 빌리루빈치는 수술 3개월 후 검사에서 모두 정상수치를 보였다. 수술 후 3개월 추적관찰 시 시행한 심초음파상 승모판막의 최대 압력차는 6.1 $\pm$ 1.8 mmHg, 평균 압력차는 3.0$\pm$0.6 mmHg이었고 유효 개구 면적은 판막 직경 27 mm, 29 mm, 31 mm, 33 mm 각각 2.54$\pm$0.56 $m^2$, 2.39 $\pm$0.73 $m^2$, 2.34 $\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$이었다. 대동맥판막의 최대 압력차는 21.1$\pm$14.12 mmHg,평균 압력차는 12.3$\pm$6.52 mmHg. 결론: On-X 판막수술 후 사망률, 판막관련합병증, 도플러 심초음파상 다른 판막들과 큰 차이를 보이지 않은 점과 NYHA Class의 호전과 정상수치를 유지하는 용혈지표를 고려한다면 비교적 좋은 결과를 보였으며 증례의 축적과 장기간의 임상분석이 이루어지면 안전하고 유용한 판막으로 입증될 것이라고 생각한다.

수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교 (Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves)

  • 강준규;홍준화;김형태;박인덕;이철주
    • Journal of Chest Surgery
    • /
    • 제38권7호
    • /
    • pp.496-500
    • /
    • 2005
  • 심장판막질환의 외과적 교정에 사용되는 수종의 기계판막들은 각기의 장점들을 주장하고 있으나, 중장기의 임상적 결과에는 유의한 차이를 보이지 않는다. 기계적 기능의 차이를 단순 비교하기는 어려우나 수술 후에 시행한 초음파심음향도로 측정한 판막간 압력차와 유효개구면적을 비교하여 다양한 기계판막들간의 기능을 비교하고자 한다. 대상 뜻 방법: 1995년부터 2003년 사이에 아주대학교병원 흥부외과에서 기계판막으로 치환술을 받았던 345명의 환자들에 사용되었던 396개의 기계판막을 대상으로 후향적 분석을 하였다. 사용되었던 판막으로는 Sorin Bicarbon, SJM, ATS, On-X, 그리고 Edward MRA로 5종류였다. 판막의 위치는 승모판막이 232개, 대동맥판막이 162, 그리고 삼첨판막이 2개였으며, 이중 다중판막치환술이 51예에서 있었다. 수술 후 14일이 지난 후에 시행한 초음파심음향도에서 유효개구면적, 수축기 평균압력차, 그리고 이완기 평균압력차를 지표로 통계학적인 비교분석을 하였다. 결과: 345명의 대상환자중 남자가 178명, 여자가 167이었고, 평균연령은 남자/여자가 $50.6\pm13.9/52.6\pm14.6$세였다. 승모판막의 경우 27mm에서는 MDPG/EOA가 Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$였으며, 31m에서는 Sorin, SJM, ATS, Mmh가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\p,0.2,\;3.7\pm1.5/2.7\pm0.7$ 였으며, 31mmdptjsms Sorin, SJM, ATS, MIRA가 $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$였으며, 33 m에서는 Sorin, SJM, MIRA가 $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$이었다. 대동맥판막의 경우 19mm에서 MSPG/EOA가 Sorin, SJM, ATS, On-X, MIRA가 $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$였으며, 21mm에서는 SJM, ATS, On-X, MIRA가 $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$였으며, 23 m에서는 Sorin, SJM, ATS On-X, MIRA가 $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$이었다 25mm에서는 SJM과 MIRA가 $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$이었다. 통계학적인 분석을 한 결과 같은 위치에 같은 크기의 판막들간에는 통계적으로 유의한 차이가 없었다. 판막재치환을 한 경우는 용혈로 인한 재치환이 ATS에서 1예, 판엽고정에 의한 재치환이 SJM에서 1예 있었다. 결론: 최근 국내에서 흔히 사용되고 있는 5종의 기계판막을 수술 후에 초음파심음향도로 추적조사한 결과 동일한 판막크기에서 각 판막간의 기능적 차이는 없는 것으로 조사되었다.