• Title/Summary/Keyword: Bileaflet Mechanical Heart Valve

Search Result 27, Processing Time 0.031 seconds

Dynamic Behavior Analysis of Mechanical Bileaflet Heart Valve Prosthesis (기계식 이엽심장밸브의 동적거동 해석)

  • 천길정
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.149-156
    • /
    • 1991
  • In this paper, fluttering behavior of mechanical bileaflet heart valve prosthesis was analyzed taking into consideration of the impact between valve plate and stopper Vibration system of the valve was modeled as a rotating system, and equations are induced by moment equilibrium equations. Lift force, drag force, gravity and buoyancy were considered as external forces acting on the valve plate/ The 4th order Runge-Kutta method was used to solve the equations. Valve plate does not come to the static equilibrium position at a stretch, but come to that position after under damping vibration. Damping ratio increases as the cardiac optput increases, and the mean damping ratio is in the range of 0.16~40.25. Fluttering frequency does not have any specific value, but varies as a function of time. It is in the range of 10~40Hz. Valve opening appears to be affected by the orientation of the of the valve relative to gravitational forces.

  • PDF

In vitro study of downstream flow passing through heart valve prostheses (인공 심장판막 하류 유동의 in vitro 연구)

  • Kim Hyoung-Bum;Lanning Craig
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • The left ventricular filling flow is now considered as an indicator which can be used for early diagnosing of cardiovascular diseases. Because the understanding of left ventricular flow physics is critical for this purpose, the downstream flow characteristics of the artificial heart valve are investigated using particle image velocimetry (PIV) method. In this study, we investigated the wake characteristics of flows passing through three different artificial valves (St.Jude medical bileaflet mechanical valve. Bjork-Shiley monostrut mechanical valve and St.Jude medical Biocor bio valve). The downstream flow field has remarkably altered according to the different valves. SJM MHV has the flow field similar to the pulsating circular jet and BS MHV has oblique pulsating jet. SJM BHV shows the similar flow field of clinical data of normal heart.

  • PDF

Numerical Study on the Pulsatile Blood Flow through a Bileaflet Mechanical Heart Valve and Leaflet Behavior Using Fluid-Structure Interaction (FSI) Technique (유체-고체 상호작용 (FSI)기법을 이용한 이엽기계식 인공심장판막을 지나는 혈액유동과 판첨거동에 관한 수치해석적 연구)

  • Choi, Choeng-Ryul;Kim, Chang-Nyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.14-22
    • /
    • 2004
  • Bileaflet mechanical valves have the complications such as hemolysis and thromboembolism, leaflet damage, and leaflet break. These complications are related with the fluid velocity and shear stress characteristics of mechanical heart valves. The first aim of the current study is to introduce fluid-structure interaction method for calculation of unsteady and three-dimensional blood flow through bileaflet valve and leaflet behavior interacted with its flow, and to overcome the shortness of the previous studies, where the leaflet motion has been ignored or simplified, by using FSI method. A finite volume computational fluid dynamics code and a finite element structure dynamics code have been used concurrently to solve the flow and structure equations, respectively, to investigate the interaction between the blood flow and leaflet. As a result, it is observed that the leaflet is closing very slowly at the first stage of processing but it goes too fast at the last stage. And the results noted that the low pressure is formed behind leaflet to make the cavitation because of closing velocity three times faster than opening velocity. Also it is observed some fluttering phenomenon when the leaflet is completely opened. And the rebounce phenomenon due to the sudden pressure change of before and after the leaflet just before closing completely. The some of time-delay is presented between the inversion point of ventricle and aorta pressure and closing point of leaflet. The shear stress is bigger and the time of exposure is longer when the flow rate is maximum. So it is concluded that the distribution of shear stress at complete opening stage has big effect on the blood damage, and that the low-pressure region appeared behind leaflet at complete closing stage has also effect on the blood damage.

Analysis of Blood Flow Interacted with Leaflets in MHV in View of Fluid-Structure Interaction

  • Park, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.613-622
    • /
    • 2001
  • Interaction of blood flow and leaflet behavior in a bileaflet mechanical heart valve was investigated using computational analysis. Blood flows of a Newtonian fluid and a non-Newtonian fluid with Carreau model were modeled as pulsatile, laminar, and incompressible. A finite volume computational fluid dynamics code and a finite element structure dynamics code were used concurrently to solve the flow and structure equations, respectively, where the two equations were strongly coupled. Physiologic ventricular and aortic pressure waveforms were used as flow boundary conditions. Flow fields, leaflet behaviors, and shear stresses with time were obtained for Newtonian and non-Newtonian fluid cases. At the fully opened phase three jets through the leaflets were found and large vortices were present in the sinus area. At the very final stage of the closing phase, the angular velocity of the leaflet was enormously large. Large shear stress was found on leaflet tips and in the orifice region between two leaflets at the final stage of closing phase. This method using fluid-structure interaction turned out to be a useful tool to analyze the different designs of existing and future bileaflet valves.

  • PDF

Pulsatile Blood Flows Through a Bileaflet Mechanical Heart Valve with Different Approach Methods of Numerical Analysis : Pulsatile Flows with Fixed Leaflets and Interacted with Moving Leaflets

  • Park, Choeng-Ryul;Kim, Chang-Nyung;Kwon, Young-Joo;Lee, Jae-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.1073-1082
    • /
    • 2003
  • Many researchers have investigated the blood flow characteristics through bileaflet mechanical heart valves using computational fluid dynamics (CFD) models. Their numerical approach methods can be classified into three types; steady flow analysis, pulsatile flow analysis with fixed leaflets, and pulsatile flow analysis with moving leaflets. The first and second methods have been generally employed for two-dimensional and three-dimensional calculations. The pulsatile flow analysis interacted with moving leaflets has been recently introduced and tried only in two-dimensional analysis because this approach method has difficulty in considering simultaneously two physics of blood flow and leaflet behavior interacted with blood flow. In this publication, numerical calculation for pulsatile flow with moving leaflets using a fluid-structure interaction method has been performed in a three-dimensional geometry. Also, pulsatile flow with fixed leaflets has been analyzed for comparison with the case with moving leaflets. The calculated results using the fluid-structure interaction model have shown good agreements with results visualized by previous experiments. In peak systole. calculations with the two approach methods have predicted similar flow fields. However, the model with fixed leaflets has not been able to predict the flow fields during opening and closing phases. Therefore, the model with moving leaflets is rigorously required for advanced analysis of flow fields.

Leaflet Escape of Edwards Duromedics Mechanical Heart Valve -Report of 1 case- (Edwards Duromedics 기계판막의 판엽 이탈 -1예 보고-)

  • 김재현;나찬영;백만종;서홍주;김종환;오삼세
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.373-375
    • /
    • 2004
  • Edwards Duromedics Valve has been suspended from the market since May 1988 due to the frequent reports of leaflet escape. There were 2 case-reports of leaflet escapes in this country. We report a case of leaflet escape in an Edwards Duromedics bileaflet valve, in the mitral position.

Interaction of Blood Flow and Leaflet Behavior in a Bileaflet Mechanical Heart Valve (기계식 인공심장판막(MHV)에서의 혈액유동과 판막운동의 상호작용)

  • 최청렬;김창녕;권영주
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.505-512
    • /
    • 2000
  • 기계식 인공심장판막을 통한 혈액의 유동과 이 유동에 관련된 판첨의 거동특성을 수치해석기법을 이용하여 연구하였다. 혈액은 맥동류, 층류, 비압축성 유동으로 가정하였으며 유체-고체의 상호작용을 고려하기 위하여 혈액의 유동방정식과 고체의 운동방정식이 동시에 계산되었다. 심실과 대동맥에서의 압력파형을 경계조건으로 사용하였다. 연구의 결과로서 혈액유동과 판첨의 거동이 예측되었으며, 판막을 통한 3개의 제트가 발견되었으며 vortex가 판첨의 끝단에서 발생하여 하부로 흘러가는 것이 관찰되었다. 판첨의 닫힘 거동은 열림 거동에 비하여 2배정도 빠르게 진행되었으며 sinus에서 2개의 큰 vortex가 관찰되었다. 유체-고체 상호작용을 고려하는 본 연구방법은 향후 판막의 연구와 개발에 매우 유용할 것으로 판단된다.

  • PDF

In-vitro Evaluation of a Bileaflet Polymer Valve and Preliminary Animal Tests (이엽식 고분자판막의 수력학적 특성평가 및 동물실험)

  • 김철생;박복춘;서수원;한동근;이규백;최진욱;김인영;김희찬;김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.225-234
    • /
    • 1992
  • In order to use a low cost polymer valve in our total artificial heart and ventricular assist device, we have developed a slit-type bileaflet polymer valve[BPV 1. The aim of this study is to determine the hydrodynamic effectiveness of the newly-designed BPV and its feasibility for temporary use in the blood pumps. For hydrodynamic comparison, we investigated in-vitro the pressure drop across the valve, the leakage volume, the flow rate and the flow pattern of the BPV, two mechanical valves and a trileaflet polymer valve. We employed the ventriculo-pulmonary bypassing method for in-vivo tests of the BPV's together vilh our electrohydraulic left venIn ricular assist device in mongrel dogs. The BPV showed adquate gydrodynamic performances and in the preliminary animal bests, there was no xvi dence of thrombus formation on the valve leaflets and around the struts. Detailed results obtained from the animal tests will be separately reported. This report involves the design criteria, fabrication and hydrodynamic charateristics of she BPV, and the basic merits and demerits of the valve are dis- cussed from the hydrodynamic point of view.

  • PDF