• 제목/요약/키워드: Bicortical

검색결과 27건 처리시간 0.022초

Comparative Analysis of Three Different Cervical Lateral Mass Screw Fixation Techniques by Complications and Bicortical Purchase : Cadaveric Study

  • Baek, Jin-Wook;Park, Dong-Mook;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.193-198
    • /
    • 2010
  • Objective : The purpose of this study is to compare the incidence of possible complications of cervical lateral screw fixation and the achievements of bicortical purchase using the Roy-Camille, Magerl and the modified methods. Methods : Six fresh-frozen cervical spine segments were harvested. The Roy-Camille technique was applied to C3 and C4, and the Magerl technique was applied to C5, C6, and C7 of one side of each cadaver. The modified technique was applied to the other side of each cadaver. The nerve root injury, violation of the facet joint, vertebral artery injury, and the bicortication were examined at each screwing level. Results : No vertebral artery injury was observed in any of the three methods. One nerve root injury was observed in each cervical spine segment using the Roy-Camille method (8.3%), the Magerl method (5.6%), and the modified method (3.3%). Facet joint injuries were observed in two cervical spinal segments using the Roy-Camille method (16.7%) and three with the Magerl method (16.7%), while five facet joint violations occurred when using the modified method (16.7%). Bicortical purchases were achieved on ten cervical spinal segments with the Roy-Camille method (83.3%) and Magerl method (55.6%), while twenty bicortical purchases were achieved in the modified method (66.7%). Conclusion : The advantages of the modified method are that it is performed by using given anatomical structures and that the complication rate is as low as those of other known methods. This modified method can be performed easily and safely without fluoroscopic assistance for the treatment of many cervical diseases.

경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교 (Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength)

  • 박춘근;황장회;지철;이재언;성재훈;최승진;이상원;;박성찬;조경석;박춘근;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1210-1219
    • /
    • 2001
  • 서 론 : 후방 경유 경추 융합을 위한 후관절 금속판 고정술은 외상성 및 퇴행성 불안정성의 치료에 효과적인 방법이다. 후관절 금속판 고정의 안정성은 여러 가지 인자에 의해 결정된다. 이중 하나가 나사못의 삽입깊이이다. 이 방법이 처음 소개될 때에는 양피질골성 삽입이 이용되었다. 외과의사의 관심은 어떻게 안전하면서 생역학적으로 강력한 고정을 얻느냐에 있다. 목 적 : 이 연구의 목적은 사체에서 단피질성과 양피질성 나사못 삽입술을 시행한 후 안전성, pull-out 강도, 방사선학적 특성을 분석하고 나사못의 삽입에 대한 교육 훈련의 수준에 따른 영향을 평가하는데 있다. 방 법 : 평균 나이 78.9세인 21구의 사체에 대하여, Magerl의 기술을 변형하여 C3-C6(n=168)까지 3.5mm AO 나사못을 양쪽 후관절에 삽입하였다. 수술중 방사선 사진영상은 사용되지 않았다. 오른 쪽(단피질성 삽입)은 14mm 나사못(11mm의 유효 길이)을 이용하고, 왼쪽은 양피질성 삽입을 시도하였다. 각 사체는 3개의 군으로 나누어 척추 수술 수련의 수준이 다른 받은 3명의 척추 외과 의사들(전임 강사, 임상 강사, 수석 레지던트)이 수술을 시행했다. 수술 후 경추를 떼어내어 나사못의 위치를 육안적으로 확인하고 방사선학적으로 안정성과 삽입 위치 (1,2,3)를 평가하였다. 척수, 후관절, 신경근과 척추 동맥에 대한 나사못의 위치를"만족할 만한","위험한", 그리고"직접적인 손상"으로 구분하였다. material testing machine을 이용하여 모든 나사못에 대해서 Pull-out 강도를 측정하였다. 결 과 : 대다수의 나사못(92.9%)은 만족할 만한 상태였다. 전예에서 척수에 대한 위험성은 없다. 오른 편(단피질성 : 14mm) 나사못의 98.9%는"만족할 만한"에 속했다. 그리고 왼쪽 편(양피질성)의 68.1%는"만족할 만한"에 속했다. 양피질성 나사못 군에서 5.8%의 척추 동맥에 대한 직접적인 손상이 있었고 신경근의 직접적인 손상 발생율은 17.4%였다. 반면에 단피질성 나사못 군에서는 이들에 대한 직접적인 손상은 없었다. 양피질성 나사못에서 보인"직접 손상"의 거의 대부분은 외과 의사의 경험 부족으로 발생하였다. 나사못의 안정성과 삽입 위치 사이에는 특별한 관련이 없었다. 모든 나사못의 pull-out 강도는 $542.0{\pm}296.6N$였다. 단피질성에 있어서의 pull-out 강도($519.0{\pm}289.9N$)와 양피질성($565.2{\pm}306N$) 나사못에는 아무런 통계학적으로 의미있는 차이점을 발견할 수 없었다(p>0.05). 나사못 삽입위치와 pull-out 강도 사이에는 의미있는 차이가 없었다. 결 론 : 이번 연구는 경추 후관절 나사못 고정술시 단피질성과 양피질성 나사못의 안정성과 효능을 집중적으로 알아보았다. 명백한 것은 14mm의 나사못(효과적인 길이는 11mm)이 보다 긴 양피질성 나사못 보다 손상의 위험이 훨씬 낮고 거의 동등한 pull-out강도를 갖는다는 것이다. 또한, 수술시 방사선 영상을 사용할 수 없을 때, 훈련과 축적된 경험에 의해 나사못 삽입의 정확성과 안전성이 향상될 수 있다.

  • PDF

Clinical Outcome of Modified Cervical Lateral Mass Screw Fixation Technique

  • Kim, Seong-Hwan;Seo, Won-Deog;Kim, Ki-Hong;Yeo, Hyung-Tae;Choi, Gi-Hwan;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권2호
    • /
    • pp.114-119
    • /
    • 2012
  • Objective : The purpose of this study was 1) to analyze clinically-executed cervical lateral mass screw fixation by the Kim's technique as suggested in the previous morphometric and cadaveric study and 2) to examine various complications and bicortical purchase that are important for b-one fusion. Methods : A retrospective study was done on the charts, operative records, radiographs, and clinical follow up of thirty-nine patients. One hundred and seventy-eight lateral mass screws were analyzed. The spinal nerve injury, violation of the facet joint, vertebral artery injury, and the bicortical purchases were examined at each lateral mass. Results : All thirty-nine patients received instrumentations with poly axial screws and rod systems, in which one hundred and seventy-eight screws in total. No vertebral artery injury or nerve root injury were observed. Sixteen facet joint violations were observed (9.0%). Bicortical purchases were achieved on one hundred and fifty-six (87.6%). Bone fusion was achieved in all patients. Conclusion : The advantages of the Kim's technique are that it is performed by using given anatomical structures and that the complication rate is as low as those of other known techniques. The Kim's technique can be performed easily and safely without fluoroscopic assistance for the treatment of many cervical diseases.

임플란트 매식조건에 따른 상, 하악골의 응력분포 양상에 대한 3차원 유한요소분석 연구 (EFFECTS OF BONE ENGAGEMENT TYPE&IMPLANT LENGTH ON STRESS DISTRIBUTION: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 최정화;서기열;최주호;한중석
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.687-697
    • /
    • 1999
  • A finite element analysis has been utilized to analyze stress and strain fields and design a new configuration in orthopedics and implant dentistry. Load transfer and stress analysis at implant bone interface are important factors from treatment planning to long term success. Bone configuration and quality are different according te anatomy of expecting implantation site. The purpose of this study was to compare the stress distribution in maxilla and mandible accord-ing to implant length and bone engagement types. A three dimensional axi-symmetric implant model(Nobel Biocare, Gothenburg, Sweden) with surrounding cortical and cancellous bone were designed to analyze the effects of bone engagement and implant length on stress distribution. ANSYS 5.5 finite element program was utilized as an interpreting toot. Three cases of unicortical anchorage model with 7, 10, 13 mm length and four cases of bicortical anchorage model with 5, 7, 10 and 13 mm length were compared both maxillary and mandibular single implant situation. Within the limits of study, following conclusions were drawn. 1. There is a difference in stress distribution according to cortical and cancellous bone thickness and shape. 2. Maximum stress was shown at the top of cortical bone area regardless of bone engagement types. 3. Bicortical engagement showed less stress accumulation when compared to unicortical case overall. 4. Longer the implant future length, less the stress on cortical bone area, however there is no difference in mandibular bicortical engagement case.

  • PDF

Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study

  • Han, Ho-Chyul;Lim, Hyun-Chang;Hong, Ji-Youn;Ahn, Su-Jin;Han, Ji-Young;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • 제46권4호
    • /
    • pp.254-265
    • /
    • 2016
  • Purpose: The aim of this study was to determine the influence of anatomical conditions on primary stability in the models simulating posterior maxilla. Methods: Polyurethane blocks were designed to simulate monocortical (M) and bicortical (B) conditions. Each condition had four subgroups measuring 3 mm (M3, B3), 5 mm (M5, B5), 8 mm (M8, B8), and 12 mm (M12, B12) in residual bone height (RBH). After implant placement, the implant stability quotient (ISQ), Periotest value (PTV), insertion torque (IT), and reverse torque (RT) were measured. Two-factor ANOVA (two cortical conditions${\times}$four RBHs) and additional analyses for simple main effects were performed. Results: A significant interaction between cortical condition and RBH was demonstrated for all methods measuring stability with two-factor ANOVA. In the analyses for simple main effects, ISQ and PTV were statistically higher in the bicortical groups than the corresponding monocortical groups, respectively. In the monocortical group, ISQ and PTV showed a statistically significant rise with increasing RBH. Measurements of IT and RT showed a similar tendency, measuring highest in the M3 group, followed by the M8, the M5, and the M12 groups. In the bicortical group, all variables showed a similar tendency, with different degrees of rise and decline. The B8 group showed the highest values, followed by the B12, the B5, and the B3 groups. The highest coefficient was demonstrated between ISQ and PTV. Conclusions: Primary stability was enhanced by the presence of bicortex and increased RBH, which may be better demonstrated by ISQ and PTV than by IT and RT.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

안면골 골절에 관한 임상적 연구 (The Clinical Study of Maxillofacial Bone Fracture)

  • 조병욱;이용찬;남종훈;김태영;고백진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 1989
  • This study is based on 247 patients(348 cases) with facial bone fracture who were admitted to the department of oral and maxillofacial surgery, Kangnam sacred heart Hospital during the period of Jan. 1983 through sep. 1988. The patients with mandible fracture were analysed with the following items such as complications with treatment method undertaken : Bicortical osteosynthesis vs Monocortical osteosynthesis, advantages and Disadvantages. The results obtained are as follows : 1) The most common age groups for the facial bone fracture were 20 years 2) The ratio of Men to women was 5 : 1 3) The most frequent location of facial bone fractures was the Mandible(76.7%), Maxillae(10.6%), Zygoma(9.5%), Nasal bone(3.2%) 4) The ratio of Mandible to Maxillae was 7.2 : 1 5) In mandible fractures, the most frequent fracture site was Symphysis(48.7%) 6) In maxilla fractures, the most frequent case was Le fort III fracture(51.4%), followed by Le fort I fracture(29.7%), Le fort II fracture(18.9%) 7) The main contributing causes of facial bone fractures were Traffic Accident(37.7%), Fight(31.6%), Accident(27.5%) 8) In open reduction methods of mandible fracture, the frequency of postop, malocclusion was 15% in interosseous wiring, 7% in Bicortical osteosynthesis, 3% in Monocortical osteosynthesis. The miniplates show advantages over other forms of fixation, in that they are malleable and easy to insert, they achieve rigid fixation and stability.

  • PDF

REMOVAL TORQUE OF BICORTICALLY STABILIZED RBM(RESORBABLE BLAST MEDIA) PIN IMPLANTS IN RABBIT TIBIA

  • Kim, Kwon-Sik;Suh, Kyu-Won;Lee, Richard Sung-Bok;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.722-733
    • /
    • 2006
  • Statement of problem. The use of small diameter implants having less than 3 mm in diameter were restricted because of lack of bonding strength to bone. Purpose. The purpose of this study was to observe how much resorbable blast media pin implants increase the binding force to the bone compared to machined transitional pin implants by measuring removal torque, and whether they can be used as final implants for replacement of small diameter teeth. Material and method. Fifteen rabbits were used in this study. Two kinds of implants (resorbable blast media pin implants and machined transitional pin implants) were inserted in each tibia bicortically. After healing time of 2, 4 and 8 weeks, the removal torque values were recorded and the rabbits were sacrificed for histological analysis. Linear finite element method analyses were conducted to compare bicortical fixation with monocortical fixation. Result and conclusion. Within the limitation of this in vivo study, the following conclusions were drawn: 1) The removal torque value of RBM pin implants showed statistically significant increase compared to machined pin implants at 2, 4, and 8 weeks respectively (p<0.05). 2) The removal torque value of RBM pin implants at 2, 4, and 8 weeks was increased statistically significantly with time (p<0.05). 3) Bicortical fixation showed better stress distribution compared with monocortical fixation in a linear finite element method analysis. 4) RBM pin implants are not recommended as transitional implants because they showed a lot of bone fracture in histologic specimens.

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy

  • Yun, Kyoung In;Cho, Young-Gyu;Lee, Jong-Min;Park, Yoon-Hee;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권5호
    • /
    • pp.271-275
    • /
    • 2012
  • Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was generated using the synthetic skull scan data, and the surface model was changed to a solid model using software. Bilateral sagittal split ramus osteotomy was performed using the program, and 8 different types of fixation methods were evaluated. A vertical load of 10 N was applied to the occlusal surface of the first molar. Results: In the case of bicortical screws, von-Mises stress on the screws and screw hole and deflection of the lower central incisor were minimal in type 2 (inverted L pattern with 3 bicortical repositioning screws). In the case of plates, von-Mises stress was minimal in type 8 (fixation 5 mm above the inferior border of the mandible with 1 metal plate and 4 monocortical screws), and deflection of the lower central incisor was minimal in types 6 (fixation 5 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws) and 7 (fixation 12 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws). Conclusion: Types 2 and 6 fixation methods provide better stability than the others.