• 제목/요약/키워드: Best fitting regression line

검색결과 4건 처리시간 0.022초

Line Fitting 을 이용한 삼차원 형상복원 (3D Shape Recovery using Line Fitting)

  • 심성오;아미르;최태선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.905-906
    • /
    • 2008
  • This paper presents a method where the best focues points are calculated using line fitting. Two datasets are selected for each pixel based on the maximum value which is calculated using Laplacian operator. Then linear regression model is used to find lines that approximate these datasets. The best fit lines are found using least squares method. After approximating the two lines, their intersection point is calculated and weights are assigned to calculate the new value for the depth map.

  • PDF

Efficient Noise Estimation for Speech Enhancement in Wavelet Packet Transform

  • Jung, Sung-Il;Yang, Sung-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권4E호
    • /
    • pp.154-158
    • /
    • 2006
  • In this paper, we suggest a noise estimation method for speech enhancement in nonstationary noisy environments. The proposed method consists of the following two main processes. First, in order to receive fewer affect of variable signals, a best fitting regression line is used, which is obtained by applying a least squares method to coefficient magnitudes in a node with a uniform wavelet packet transform. Next, in order to update the noise estimation efficiently, a differential forgetting factor and a correlation coefficient per subband are used, where subband is employed for applying the weighted value according to the change of signals. In particular, this method has the ability to update the noise estimation by using the estimated noise at the previous frame only, without utilizing the statistical information of long past frames and explicit nonspeech frames by voice activity detector. In objective assessments, it was observed that the performance of the proposed method was better than that of the compared (minima controlled recursive averaging, weighted average) methods. Furthermore, the method showed a reliable result even at low SNR.

Revisiting the virial factor with the updated $M_{BH}-{\sigma}_*$ relation

  • 박대성;우종학
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.35.1-35.1
    • /
    • 2012
  • Determining the virial factor of the broad-line region (BLR) gas is crucial in calibrating AGN black hole mass estimators, since the measured line-of-sight velocity needs to be converted into the representative velocity of the BLR gas. The unknown virial factor has been empirically calibrated based on the $M_{BH}-{\sigma}_*$ relation of non-AGN galaxies, but the claimed values are different by a factor of 2 in recent studies. We investigate the origin of the difference by measuring the $M_{BH}-{\sigma}_*$ relation using the most updated nearby galaxy sample, and explore the dependence of the virial factor on the various fitting methods. We find that the discrepancy is mostly caused by the sample bias while the difference stemming from various regression methods is marginal. Based on the best-determined virial factor, we present the updated $M_{BH}-{\sigma}_*$ relation of local active galaxies.

  • PDF

Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting

  • Birgani, Mohammadjavad Tahmasebi;Fatahiasl, Jafar;Hosseini, Seyed Mohammad;Bagheri, Ali;Behrooz, Mohammad Ali;Zabiehzadeh, Mansour;meskani, Reza;Gomari, Maryam Talaei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권17호
    • /
    • pp.7785-7788
    • /
    • 2015
  • Utilization of high energy photons (>10MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6MV photons and then these calculations were repeated ten times with incorporating 18MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV ($D_{max}$) and the volume of CTV which covered with 95% Isodose line ($V_{CTV,95%IDL}$) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18MV photons was defined as the intersection point of $D_{max}$ and $V_{CTV,95%IDL}$ graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.