• Title/Summary/Keyword: Bending Collapse

Search Result 139, Processing Time 0.028 seconds

Experimental Study on Flexural Behavior of CFT Girder-Deck Composite Section (콘크리트 충전 강관 거더-바닥판 합성단면의 휨거동에 관한 실험적 연구)

  • Chin, Won-Jong;Kang, Jae-Yoon;Choi, Eun-Suk;Lee, Jung-Woo;Lee, Heung-Soo;Kwark, Jong-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.166-169
    • /
    • 2006
  • A new bridge system described in this paper uses concrete-filled steel tube (CFT) girders as a replacement for conventional girders. Experimental investigations were carried out to comprehend the flexural behavior of CFT girder-slab deck composite section. The experimental investigation consisted of designing and constructing a test specimen and loading it to collapse in bending to check the applicability of the system. The test results showed that concrete filled steel tube girders have good ductility and maintain its strength up to the end of the loading. In the test, the flexural behavior of each specimen of CFT girder-deck composite section is identified.

  • PDF

An Analytic Study of Composite Hollow Core Slab Subjected with Box Type Beams (박스형 철골빔이 적용된 프리스트레스 할로우-코어 합성슬래브의 해석연구)

  • Hong, Sung-Gul;Seo, Do-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.311-314
    • /
    • 2005
  • This research aims to analyze of prestressed composite hollow-core slab and box type steel beam. The smeared crack model used in abaqus for the modeling of hollow core reinforced concrete, including cracking of the concrete, rebar and concrete interaction using the tension stiffening concept, and rebar yield. The structure modeled is a simply supported hollow core spancrete slab subjected spa-h beams and prestressed in one direction. The hollow core spancrete slab is subjected to four-point bending. The concrete-rebar interaction that occur as the concrete begins to crack are of major importance in determining the spancrete slab's response between its initial, deformation and its collapse. This smeared crack model used in analysis involved non-liner concrete analysis concept.

  • PDF

Effect of Wire Bracing to Snow Load Acting on Vinyl House Frame (적설하중이 작용하는 비닐하우스 골조에 대한 강선보강효과)

  • Jung, Dong-Jo;Teng, Chhay
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2010
  • Unbraced vinyl house frame that is economically installed is certainly easy to collapse under the influence of excess snow load. To make it more cheaply in putting up as well as more efficiently in withstanding the applied snow load, it is essential to insert additional bracing into the existing unbraced vinyl house frame. On the other hand, there are varieties of possible bracing shapes that can be formed. However, their efficiencies are different. Therefore, it is important to identify the most effective bracing shape. In this study, 2 different kinds of bracing shapes, horizontal and inclined bracing, are used to additionally install in the ordinary single frames in order to show the effect of the bracing resisting the applied snow load and compare the bending moment, axial force, combined stress and vertical displacement of the vinyl house frame.

Failure analysis of ribbed cross-laminated timber plates

  • Lavrencic, Marko;Brank, Bostjan
    • Coupled systems mechanics
    • /
    • v.7 no.1
    • /
    • pp.79-93
    • /
    • 2018
  • The process of material failure i.e. cracks development and their propagation in an experiment related to the bending collapse of cross laminated timber plate with ribs is described. Numerical simulation of such an experiment by the nonlinear finite element method is presented. The numerical model is based on Hashin failure criteria, initially developed for unidirectional composites, and on material softening concept applied by the smeared crack approach. It is shown that such a numerical model can be used for an estimation of the limit load and the limit displacement of a cross laminated timber ribbed plate.

Frontal Crashworthiness Analysis of Vehicle Using simplified Structure Modelling (단순 차체 모델링을 이용한 차량 정면충돌해석)

  • 김홍수;강신유;이인혁;박신희;한동철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.23-30
    • /
    • 1997
  • Modelling and crashworthiness analysis of simplified vehicle structures with beam element and nonlinear spring element to which axial and bending collapse mecha- nisms are applied are carried out. And on the basis of these analyses, two types of full car modelling and crahworthiness analyses with nonlinear spring and beam element are accomplished. The one is the full car model of which 30% of the structures are modelled with nonlinear spring and beam element, and the other 75% of whole structures. And the results are compared with those of full car analysis with shell element.

  • PDF

The Ultimate Load Capacity of Plates by Elastic-Perfectly Plastic Model (탄성-완전소성모델에 의한 평판의 극한내하력 산정)

  • 박진환;정우성;우광성
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.1
    • /
    • pp.1-14
    • /
    • 1999
  • 선형탄성이론을 기초로 한 구조해석의 경우 사용하중상태에서의 변형과 응력은 만족할 만한 결과를 나타내지만, 항복후의 처짐과 파괴시의 극한하중 산정의 정확한 해석이 불가능하다. 평판의 극한해석시, 상한계 이론을 바탕으로 한 항복선 이론이 널리 사용되고 있으나 이론적으로 평판의 강도를 과대평가하게 된다. 그러므로, 임의의 하중조건과 경계조건에 대한 비선형 거동과 극한내하력을 산정할 수 있는 해석기법이 필요하다. 평판의 정확한 극한하중을 위해 p-Version 유한요소법을 제안하며, p-Version의 해석치를 범용 구조해석 프로그램인 ADINA의 결과와 문헌의 이론치와 비교하였다.

  • PDF

Ultimate behavior of composite beams with shallow I-sections

  • Gorkem, Selcuk Emre;Husem, Metin
    • Steel and Composite Structures
    • /
    • v.14 no.5
    • /
    • pp.493-509
    • /
    • 2013
  • Bending behavior of reinforced concrete slabs encased over shallow I-sections at different levels of compression heads were investigated in present study. 1500 mm long I-sections were used to create composite slabs. Compression heads of monolithic experimental members were encased at different levels into the concrete slabs. Shear connections were welded over some of the I-sections. The testing was carried out in accordance with the principles of four-point loading. Results revealed decreasing load bearing and deflection capacities of composite beams with increasing encasement depths into concrete. Mechanical properties of concrete and reinforcing steel were also examined. Resultant stresses calculated for composite beams at failure were found to be less than the yield strength of steel beams. Test results were discussed with regard to shear and slip effect.

Structural Damage and Residual Strength of Ships in Grounding with a Forward Speed (전진형 좌초시 선박의 구조손상 및 잔류강도)

  • J.K. Paik;T.K. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.73-86
    • /
    • 1995
  • In this paper, the mechanics of ships in grounding with a forward speed is analyzed. A raking damage estimate model in grounding of ships is proposed. The accuracy and applicability of the model are verified by a comparison of experimental results. The progressive collapse analysis of damaged gull sections under vertical bending moments is described by using the ALPS/ISUM computer code. The procedure is applied to grounding simulation of a double hull tanker with a transverseless system.

  • PDF

Effects of face-sheet materials on the flexural behavior of aluminum foam sandwich

  • Xiao, Wei;Yan, Chang;Tian, Weibo;Tian, Weiping;Song, Xuding
    • Steel and Composite Structures
    • /
    • v.29 no.3
    • /
    • pp.301-308
    • /
    • 2018
  • Properties of AFS vary with the changes in the face-sheet materials. Hence, the performance of AFS can be optimized by selecting face-sheet materials. In this work, three types of face-sheet materials representing elastic-perfectly plastic, elastic-plastic strain hardening and purely elastic materials were employed to study their effects on the flexural behavior and failure mechanism of AFS systematically. Result showed face-sheet materials affected the failure mechanism and energy absorption ability of AFS significantly. When the foam cores were sandwiched by aluminum alloy 6061, the AFS failed by face-sheet yielding and crack without collapse of the foam core, there was no clear plastic platform in the Load-Displacement curve. When the foam cores were sandwiched by stainless steel 304 and carbon fiber fabric, there were no face-sheet crack and the sandwich structure failed by core shear and collapse, plastic platform appeared. Energy absorption abilities of steel and carbon fiber reinforced AFS were much higher than aluminum alloy reinforced one. Carbon fiber was suggested as the best choice for AFS for its light weight and high performance. The versus strength ratio of face sheet to core was suggested to be a significant value for AFS structure design which may determine the failure mechanism of a certain AFS structure.

Responses of self-anchored suspension bridge to sudden breakage of hangers

  • Qiu, Wenliang;Jiang, Meng;Zhang, Zhe
    • Structural Engineering and Mechanics
    • /
    • v.50 no.2
    • /
    • pp.241-255
    • /
    • 2014
  • The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of a concrete self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger has significant effects on tensions of the hangers next to the broken hanger, bending and torsion moments of the girder, moments of the towers and reaction forces of the bearings. The results obtained from dynamic analysis method are very different from those obtained from static analysis method. The maximum tension of hanger produced by breakage of a hanger exceeds 2.2 times of its initial value, the maximum dynamic amplification factor reaches 2.54, which is larger than the value of 2.0 recommended for cable-stayed bridge in PTI codes. If two adjacent hangers on the same side of bridge break one after another, the maximum tension of other hangers exceeds 3.0 times of its initial value. If the safety factor adopted to design hanger is too small, or the hangers have been exposed to corrosion, the bridge may collapse due to breakage of two adjacent hangers.