• 제목/요약/키워드: Bench-scale

검색결과 355건 처리시간 0.035초

Removal of Perchlorate Using Reverse Osmosis and Nanofiltration Membranes

  • Han, Jonghun;Kong, Choongsik;Heo, Jiyong;Yoon, Yeomin;Lee, Heebum;Her, Namguk
    • Environmental Engineering Research
    • /
    • 제17권4호
    • /
    • pp.185-190
    • /
    • 2012
  • Rejection characteristics of perchlorate ($ClO_4^-$) were examined for commercially available reverse osmosis (RO) and nanofiltration (NF) membranes. A bench-scale dead-end stirred-cell filtration system was employed to determine the toxic ion rejection and the membrane flux. Model water solutions were used to prepare $ClO_4^-$ solutions (approximately, $1,000{\mu}g/L$) in the presence of background salts (NaCl, $Na_2SO_4$, and $CaCl_2$) at various pH values (3.5, 7, and 9.5) and solution ionic strengths (0.001, 0.01, and 0.01 M NaCl) in the presence of natural organic matter (NOM). Rejection by the membranes increased with increasing solution pH owing to increasingly negative membrane charge. In addition, the rejection of the target ion by the membranes increased with increasing solution ionic strength. The rejection of $ClO_4^-$ was consistently higher for the RO membrane than for the NF membrane and $ClO_4^-$ rejection followed the order $CaCl_2$ < NaCl < $Na_2SO_4$ at conditions of constant pH and ionic strength for both the RO and NF membranes. The possible influence of NOM on $ClO_4^-$ rejection by the membranes was also explored.

고고도 무인기용 수소 엔진의 시동성 및 공회전 연소 특성 (Start and Idle Combustion Characteristics of Hydrogen Engine for the HALE UAV)

  • 김용래;최영;이장희
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.22-27
    • /
    • 2015
  • 최근 고고도 장기체공 무인기의 개발이 활발하게 진행되고 있는 가운데, 중량당 에너지 밀도가 높아서 왕복동 엔진의 연료로서 적합한 수소 연료를 적용하는 것이 경제성과 기술성 측면에서 유리한 것으로 검토되었다. 본 연구에서는 2.4리터급 왕복동 가솔린엔진을 수소엔진으로 개조하기 위하여 수소연료를 공급하기 위한 실험장치를 구축하고 수소연료 공급이 가능한 인젝터를 장착하였으며 범용 엔진제어기를 이용하여 엔진을 구동시킴으로써 시동 및 공회전 시의 연소 특성을 파악하였다. 안전하게 엔진 시동성을 확보하였고 공회전 상태를 유지할 수 있는 조건을 탐색하였다. 또한 공회전 상태에서 공연비와 점화 타이밍을 변경해보면서 연소 안정성을 비롯한 기본적인 연소 특성을 살펴봄으로써 향후 수소엔진을 활용한 무인기의 동력원을 개발하기 위한 기초를 마련하였다.

A/O 및 A2/O공정의 생물학적 인제거 특성비교 (Comparison of Biological Phosphorus Removal Characteristics between A/O and A2/O Process)

  • 김광수;서규태;이경호;김낙주
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.123-130
    • /
    • 2002
  • Bench scale experiments were carried out with two biological nutrient removal(BNR) units, A/O and $A^2O$ processes, to investigate the behavior of phosphorus in the system and to compare the characteristics of phosphorus removal in two BNR processes. To achieve this goal, COD/T-P and COD/TKN ratios of the influent was varied in the range of 23~64 and 5~24, respectively. In A/O process, influent COD/T-P ratio should be kept higher than 44mg/L to meet the final effluent T-P concentration lower than 1mg/L and in $A^2/O$ process, influent COD/T-P and COD/TKN ratios higher than 56 and 10, respectively, were required for good phosphorus release and uptake with no influence of nitrate nitrogen in return sludge. At this conditions, the rate of phosphorus release in the anaerobic basin should be kept higher than 0.1 kg S-P/kg MLVSS d In A/O process, the phosphorus content of anaerobic and aerobic sludges was increased as SRT of total system was becoming longer resulting in decreasing the difference of phosphorus content between two sludges while phosphorus release in anaerobic basin and phosphorus uptake in aerobic basin was not incident. In $A^2/O$ process, the phosphorus content of anaerobic and aerobic sludges were not increased with higher SRT of total system due to the relatively high nitrate concentration in return sludge. However, the difference of phosphorus content between anaerobic and aerobic sludges was incident when phosphorus release and uptake was observed.

n-Dodecane 연료의 고온면 점화특성 (Ignition Characteristics of n-Dodecane Fuel Droplet on a Hot Surface)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.116-121
    • /
    • 2010
  • n-dodecane 연료 액적의 고온면 점화특성을 파악하기 위해 본 연구에서는 공기의 공급과 제어가 가능한 실험실 규모의 실험 장치를 제작하였다. 표면온도는 적외선 측정법에 의해 계측되었으며 적외선 측정법에 의해 계측된 온도는 k-type 열전대에 의해 측정된 온도와 비교하여 $10^{\circ}C$ 이내의 오차를 보였다. 각 공기 공급유량에 대하여 약 400회의 점화실험이 수행되었으며 점화실험결과로부터 점화확률 분포와 최소 점화온도에 관한 결과를 얻었다. 공기 공급유량이 3.0lpm인 경우를 제외하고 냉염과 열염 점화특성을 보였으며 공기 공급유량에 따라 냉염점화가 일어나는 온도범위가 큰 차이를 보였다. 실험결과 n-dodecane 연료의 최소고온면점화온도(MHSIT)는 공기공급 유량이 0.5lpm인 경우에 대하여 약 $300^{\circ}C$를 나타냈다. 본 연구에서는 외기조건에 따른 점화특성을 파악함으로써 초기 발화 메커니즘을 이해하고 조기화재 진압을 위한 시스템 설계의 기초적 자료로 활용된다.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

From Bench to Market: Preparing Human Pluripotent Stem Cells Derived Cardiomyocytes for Various Applications

  • Moon, Sung-Hwan;Bae, Daekyeong;Jung, Taek-Hee;Chung, Eun-Bin;Jeong, Young-Hoon;Park, Soon-Jung;Chung, Hyung-Min
    • International Journal of Stem Cells
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 2017
  • Human cardiomyocytes (CMs) cease to proliferate and remain terminally differentiated thereafter, when humans reach the mid-20s. Thus, any damages sustained by myocardium tissue are irreversible, and they require medical interventions to regain functionality. To date, new surgical procedures and drugs have been developed, albeit with limited success, to treat various heart diseases including myocardial infarction. Hence, there is a pressing need to develop more effective treatment methods to address the increasing mortality rate of the heart diseases. Functional CMs are not only an important in vitro cellular tool to model various types of heart diseases for drug development, but they are also a promising therapeutic agent for cell therapy. However, the limited proliferative capacity entails difficulties in acquiring functional CMs in the scale that is required for pathological studies and cell therapy development. Stem cells, human pluripotent stem cells (hPSCs) in particular, have been considered as an unlimited cellular source for providing functional CMs for various applications. Notable progress has already been made: the first clinical trials of hPSCs derived CMs (hPSC-CMs) for treating myocardial infarction was approved in 2015, and their potential use in disease modeling and drug discovery is being fully explored. This concise review gives an account of current development of differentiation, purification and maturation techniques for hPSC-CMs, and their application in cell therapy development and pharmaceutical industries will be discussed with the latest experimental evidence.

지연성근육통 유발 후 수동적 스트레칭이 혈중피로물질 및 VAS에 미치는 융합연구 (Convergence Study on Effects of Passive Stretching on Blood Fatigue and VAS after Delayed Onset Muscle Soreness)

  • 김종혁;김도진
    • 융합정보논문지
    • /
    • 제8권6호
    • /
    • pp.93-99
    • /
    • 2018
  • 본 연구는 대학생을 대상으로 지연성근육통 유발 후 수동적 스트레칭의 효과를 확인하고 부상 시 효과적인 통증완화 및 예방을 위한 재활 운동프로그램을 제안하고자 한다. 연구대상자는 20대 남자 대학생을 대상으로 수동적 스트레칭그룹과 통제그룹으로 구분하였다. 수동적 스트레칭 그룹은 지연성근육통 유발 후 수동적 스트레칭을 실시하였으며 통제그룹은 지연성근육통 유발 후 어떠한 처치도 실시하지 않았다. 지연성근육통 유발 방법은 벤치 스텝 운동을 통하여 유발하였으며, 스텝박스의 높이는 50cm이며, 착지 시 왼쪽 하지 쪽으로 착지하도록 하였다. 측정변인은 혈중피로물질과 주관적 통증척도를 알아보았으며 자료처리는 수동적 스트레칭 그룹과 통제그룹의 비교를 위하여 2-way RGRM ANOVA를 실시하였다. 결론적으로 지연성근육통 유발 후 수동적 스트레칭이 혈중피로물질(CRP, LDH)과 주관적 통증척도(VAS)에 긍정적 효과가 있는 것으로 나타났다.

Analyses of intermediate products during degradation of pyrene in soil by hemoglobin-catalyzed reaction

  • Keum, Haein;Kang, Guyoung
    • Journal of Applied Biological Chemistry
    • /
    • 제61권4호
    • /
    • pp.335-340
    • /
    • 2018
  • Hemoglobin (Hb) is a member of heme-protein that can perform catalytic non-specific chain reaction in the presence of hydrogen peroxide ($H_2O_2$). Catalytic ability of Hb to degrade pyrene was demonstrated using soil contaminated with $^{14}C$ pyrene and 10 mg pyrene /kg soil. The composition of soil was similar to previously used soil except that it had lower organic carbon content. Bench scale laboratory tests were conducted in the presence of buffer only, $H_2O_2$ only, or Hb with $H_2O_2$ for 24 h. After 24 h reaction, 0.1 and 1.3% of $^{14}C$ pyrene in contaminated soil were mineralized with $H_2O_2$ only or Hb plus $H_2O_2$. No mineralization to $^{14}CO_2$ was detected with buffer only. Approximately 12.2% of pyrene was degraded in the presence of $H_2O_2$ only while 44.0% of pyrene was degraded in the presence of Hb plus $H_2O_2$ during 24 h of catalytic reaction. When degradation intermediate products were examined, two chemicals were observed in the presence of $H_2O_2$ only while 25 chemicals were found in the presence of Hb plus $H_2O_2$. While most degradation products were simple hydrocarbons, four of the 27 chemicals had aromatic rings. However, none of these four chemicals was structurally related to pyrene. These results suggest that Hb catalytic system could be used to treat pyrene-contaminated soil as an efficient and speedy remediation technology. In addition, intermediate products generated by this system are not greatly affected by composition change in soil organic matter content.

벤치 규모 연속반응시스템에서 저급 열분해유 분해반응에 대한 반응온도 프로그램의 영향 (Effect of Reaction Temperature Program on Thermal Degradation of Low-quality Pyrolytic Oil for Bench-scale Continuous Reaction System)

  • 이경환;남기윤
    • 청정기술
    • /
    • 제15권3호
    • /
    • pp.186-193
    • /
    • 2009
  • 본 연구에서는 상용운전 중에 있는 반연속식 로터리 킬른형 열분해반응기에 지자체에서 발생되는 필름형 혼합 폐플라스틱을 투입한 후 열분해하여 얻은 저급의 열분해유를 세 형태의 반응온도 프로그램에서 분해반응시키고, 여기에서 얻어지는 생성유의 특성을 논의하였다. 원료인 저급 열분해유의 특성은 원소분석 및 발열량 분석, SIMDIST 분석으로 확인하였고, 각 반응온도 프로그램에 따른 분해반응 결과는 각 성분의 수율분포, 액상 생성물의 누적수율과 생성비 등으로 논의하였다. 연구결과는 한 단계 반응온도 프로그램에 비해 다단계 반응온도 프로그램의 경우가 원하는 생성물인 오일수율이 높았고, 상대적으로 잔류물의 수율은 낮게 나타났다. 연속적인 열분해반응에서 반응온도 프로그램은 생성물의 수율분포 등 생성유 특성에 많은 영향을 주었다.

벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가 (Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process)

  • 김재영;임호;우제민;조성호;문종호;이승용;이효진;이창근;이종섭;민병무;박영철
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.419-425
    • /
    • 2017
  • 본 연구에서는 벤치급 건식 $CO_2$ 포집 성능평가 장치에서 흡수반응기 내부의 구조와 형태에 따른 K-계열 흡수제(KEP-CO2P2, 한국전력공사 전력연구원)의 성능특성을 확인하였다. 흡수반응기 혼합영역(mixing-zone)에 구조와 형태가 다르게 제작된 두 종류의 열교환기가 적용되었으며, 각각 CASE 1과 CASE 2로 나뉘어 동일한 조업조건으로 연속운전을 수행하였다. 연속운전동안 흡수반응 온도는 $75{\sim}80^{\circ}C$, 재생반응 온도는 $190{\sim}200^{\circ}C$, 그리고 반응기체($CO_2$) 농도는 12~14 vol%으로 설정하였다. 특히 흡수제의 흡수능 비교를 위해 흡수반응기 혼합영역의 차압을 400~500 mm$H_2O$로 유지하며 운전하였다. 또한 반응 후 채집한 시료는 반응성 비교를 위해 TGA를 이용하여 물성분석을 하였다. CASE 1 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 64.3%, 2.40 wt%으로 산출 되었고, CASE 2 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 81.0%, 4.66 wt%으로 산출되었다. 또한 반응 후 흡수제에 대한 TGA 측정 결과의 무게감량을 이용하여 흡수제의 동적흡수능을 계산한 결과, CASE 1과 CASE 2 실험에서 반응 후 흡수제의 동적흡수능은 각각 2.51 wt%와 4.89 wt%으로 산출되었다. 결론적으로 동일한 조업조건에서 흡수반응기 내부에 삽입되는 열교환기의 구조와 형태에 따라 흡수제의 성능 차이가 있는 것을 확인하였다.