Performance of HFC152a, HFC134a and HC290 Mixtures as Alternative Refrigerants for HFC134a (HFC152a, HFC134a, 프로판을 포함한 자동차용 대체/보충 냉매의 성능)

  • Kang, Nam-Koo;Bae, Guen-Hwan;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.383-391
    • /
    • 2010
  • In this study, HFC152a, HFC134a/HFC152a and HC290/HFC134a/HFC152a mixtures are studied for the supplementary and alternative refrigerants for HFC134a used in automobile air-conditioners. Due to the high global warming potential of HFC134a, it has to be phased out in the long run. Thermodynamic performance of these refrigerants are measured in a bench tester of 3.5 kW capacity with an open type compressor under both summer and winter conditions. Test results show that the coefficient of performance (COP) and capacity of pure HFC152a and HFC134a/HFC152a mixture are 9.1~12% and 7% higher than those of HFC134a. As for the HC290/HFC134a/HFC152a, the COP is up to 9.5% higher than that of HFC134a with 1~2% of HC290 while that is up to 6.1% lower than that of HFC134a with 5% HC290. The capacity of the ternary mixture, however, is 8.6% higher than that of HFC134a at all compositions tested. The compressor discharge temperatures of all refrigerants tested are $6{\sim}10^{\circ}C$ higher than that of HFC134a. For all refrigerants, the amount of charge is reduced up to 32% due to the decrease in liquid density. Overall, these refrigerants provide good performance with reasonable energy savings with less environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

Dynamics of Hexavalent Chromium in Four Types of Aquaculture Ponds and Its Effects on the Morphology and Behavior of Cultured Clarias gariepinus (Burchell 1822)

  • Mustapha, Moshood Keke
    • Toxicological Research
    • /
    • v.33 no.2
    • /
    • pp.119-124
    • /
    • 2017
  • Hexavalent chromium is a bio accumulative toxic metal in water and fish. It enters aquaculture ponds mainly through anthropogenic sources. Hexavalent chromium concentrations and its effects on the morphology and behavior of Clarias gariepinus were investigated from four aquaculture ponds for 12 weeks. Chromium was measured using diphenyl carbohdrazide method; alkalinity and hardness were measured using colometric method and analyzed with Bench Photometer. Temperature and pH were measured using pH/EC/TDS/Temp combined tester. Temporal and spatial replications of samples were done with triplicates morphological and behavioural effects of the metal on fish were observed visually. Chromium ranged from no detection to 0.05 mg/L, alkalinity 105 to 245 mg/L, hardness 80 to 165 mg/L, pH 6.35 to 8.03 and temperature 29.1 to $35.9^{\circ}C$. Trend in the chromium concentrations in the ponds is natural > earthen > concrete > collapsible. There was a significant difference (P < 0.05) in chromium, alkalinity, water hardness, pH and temperature among the four ponds. Significant positive correlation also existed between alkalinity, water hardness, pH, with chromium. Morphological and behavioural changes observed in the fish include irregular swimming, frequent coming to the surface, dark body colouration, mucous secretion on the body, erosion of gill epithelium, fin disintegration, abdominal distension and lethargy. High chromium concentration in natural pond was due to anthropogenic run-off of materials in to the pond. Acidic pH, low alkalinity, low water hardness also contributed to the high chromium concentration. Morphological and behavioural changes observed were attributed to the high concentrations, toxicity and bio accumulative effect of the metal. Toxicity of chromium to fish in aquaculture could threaten food security. Watershed best management practices and remediation could be adopted to reduce the effects of toxicity of chromium on pond water quality, fish flesh quality and fish welfare.

Performance of HFC32/HFC125 Mixtures for Heat Pumps (HFC32/HFC125 혼합냉매의 히트펌프 성능 평가)

  • Kim, Wook-Jin;Kang, Dong-Gyu;Lee, Yo-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.