• Title/Summary/Keyword: Bench

Search Result 1,097, Processing Time 0.024 seconds

A Study on the Design and Behavioral Analysis of Commercial Rest Area -Focused on the Rest Area and Furniture of Shinsegae Department Store, Busan- (상업 휴게 공간의 디자인과 이용 행태 연구 -부산 신세계 백화점 휴게 공간과 가구를 중심으로-)

  • Yu, DeSheng;Yoon, Ji-Young
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.9
    • /
    • pp.280-292
    • /
    • 2019
  • This study was carried out for the Centum Shinsegae Department Store, to grasp the indoor rest space and furniture design status, this study analyzes the characteristics of visitors' use behavior centered on furniture. The purpose of this study is to provide basic data for commercial rest space design by understanding the characteristics of resting space in commercial space and whether the furniture can support the behavior of visitors. The research method is to carry out on-site inspection, including the location of the rest space on each floor, the type and design characteristics of the furniture design, and the characteristics and patterns of the users on each were analyzed. The results of the study are as follows. As a result of analyzing the rest space and furniture, the furniture is brown, it has been provided with various designs such as fan-shaped, arched bench, sofa, chair type, and comfortable colors of lightness ranging from light gray to black, and appropriately supported the most common usage patterns.However, in the case of Shinsegae Department Store, it is necessary to consider the safety and convenience of the vulnerable groups.

Analyses of intermediate products during degradation of pyrene in soil by hemoglobin-catalyzed reaction

  • Keum, Haein;Kang, Guyoung
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.4
    • /
    • pp.335-340
    • /
    • 2018
  • Hemoglobin (Hb) is a member of heme-protein that can perform catalytic non-specific chain reaction in the presence of hydrogen peroxide ($H_2O_2$). Catalytic ability of Hb to degrade pyrene was demonstrated using soil contaminated with $^{14}C$ pyrene and 10 mg pyrene /kg soil. The composition of soil was similar to previously used soil except that it had lower organic carbon content. Bench scale laboratory tests were conducted in the presence of buffer only, $H_2O_2$ only, or Hb with $H_2O_2$ for 24 h. After 24 h reaction, 0.1 and 1.3% of $^{14}C$ pyrene in contaminated soil were mineralized with $H_2O_2$ only or Hb plus $H_2O_2$. No mineralization to $^{14}CO_2$ was detected with buffer only. Approximately 12.2% of pyrene was degraded in the presence of $H_2O_2$ only while 44.0% of pyrene was degraded in the presence of Hb plus $H_2O_2$ during 24 h of catalytic reaction. When degradation intermediate products were examined, two chemicals were observed in the presence of $H_2O_2$ only while 25 chemicals were found in the presence of Hb plus $H_2O_2$. While most degradation products were simple hydrocarbons, four of the 27 chemicals had aromatic rings. However, none of these four chemicals was structurally related to pyrene. These results suggest that Hb catalytic system could be used to treat pyrene-contaminated soil as an efficient and speedy remediation technology. In addition, intermediate products generated by this system are not greatly affected by composition change in soil organic matter content.

Stability evaluation of a proportional valve controller for forward-reverse power shuttle control of agricultural tractors

  • Jeon, Hyeon-Ho;Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Hyeon;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.3
    • /
    • pp.597-606
    • /
    • 2021
  • Due to the characteristics of the farmland in Korea, forward and reverse shift is the most used. The fatigue of farmers is caused by forward and reverse shifting with a manual transmission. Therefore, it is necessary to improve the convenience of forward and backward shifting. This study was a basic study on the development of a current control system for forward and reverse shifting of agricultural tractors using proportional control valves and a controller. A test bench was fabricated to evaluate the current control accuracy of the control system, and the stability of the controller was evaluated through CPU (central processing unit) load measurements. A controller was selected to evaluate the stability of the proportional valve controller. The stability evaluation was performed by comparing and analyzing the command current of the controller and the actual current measured. The command current was measured using a CAN (controller area network) communication device and DAQ (data acquisition). The actual current was measured with a current probe and an oscilloscope. The control system and stability evaluation was performed by measuring the CPU load on the controller during control operations. The average load factor was 12.27%, and when 5 tasks were applied, it was shown to be 70.65%. This figure was lower than the CPU limit of 74.34%, when 5 tasks were applied and was judged to be a stable system.

Case Study on the Building Organization of Medibio Research Laboratory Facilities in Research-driven Hospital (연구중심병원 의생명연구원의 실험실 구성 사례 조사)

  • Kim, Young-Aee
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.95-104
    • /
    • 2018
  • Healthcare technology has been growing and fostering cooperation between industry, university and hospitals as growth engines in korea. So, the medibio research institutes in hospital have been constructed to promote research and industrialization centering on healthcare technology. The purpose of this study is to investigate the cases of research institutes in hospitals, and search the characteristics of building organization of medibio research laboratory facilities. Case study is investigated by floor plan, homepage and site visits about five research institutes selected in research-driven hospitals. The facility title and size of research laboratory is originated from site area and research building location. The building function include not only the research lab and business office reflecting on the development platform, and but assembly and meeting room in the ground level. Laboratory floor plans have three types, rectangular, rectangular+linear and linear type, one is traditional and efficient, the others are people and friendly. And building core types are correlated with lab space unit modules, single and double side core are shown in rectangular type. All the laboratories are open lab, composed with laboratory bench and research note writing desk facing the lab service and enclosed lab-support area. And they have communication space looking as warm and cozy common area for the innovation, convergence and collaboration. As the high risk of contamination and high standard for safety and security, equipment and facilities are well managed with biological environment including BSC, fume hood, PCR classification, eye washing and emergency shower.

A New Approach for Detection of Gear Defects using a Discrete Wavelet Transform and Fast Empirical Mode Decomposition

  • TAYACHI, Hana;GABZILI, Hanen;LACHIRI, Zied
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • During the past decades, detection of gear defects remains as a major problem, especially when the gears are subject to non-stationary phenomena. The idea of this paper is to mixture a multilevel wavelet transform with a fast EMD decomposition in order to early detect gear defects. The sensitivity of a kurtosis is used as an indicator of gears defect burn. When the gear is damaged, the appearance of a crack on the gear tooth disrupts the signal. This is due to the presence of periodic pulses. Nevertheless, the existence of background noise induced by the random excitation can have an impact on the values of these temporal indicators. The denoising of these signals by multilevel wavelet transform improves the sensitivity of these indicators and increases the reliability of the investigation. Finally, a defect diagnosis result can be obtained after the fast transformation of the EMD. The proposed approach consists in applying a multi-resolution wavelet analysis with variable decomposition levels related to the severity of gear faults, then a fast EMD is used to early detect faults. The proposed mixed methods are evaluated on vibratory signals from the test bench, CETIM. The obtained results have shown the occurrence of a teeth defect on gear on the 5th and 8th day. This result agrees with the report of the appraisal made on this gear system.

Development and Characterization of an Atmospheric Turbulence Simulator Using Two Rotating Phase Plates

  • Joo, Ji Yong;Han, Seok Gi;Lee, Jun Ho;Rhee, Hyug-Gyo;Huh, Joon;Lee, Kihun;Park, Sang Yeong
    • Current Optics and Photonics
    • /
    • v.6 no.5
    • /
    • pp.445-452
    • /
    • 2022
  • We developed an adaptive optics test bench using an optical simulator and two rotating phase plates that mimicked the atmospheric turbulence at Bohyunsan Observatory. The observatory was reported to have a Fried parameter with a mean value of 85 mm and standard deviation of 13 mm, often expressed as 85 ± 13 mm. First, we fabricated several phase plates to generate realistic atmospheric-like turbulence. Then, we selected a pair from among the fabricated phase plates to emulate the atmospheric turbulence at the site. The result was 83 ± 11 mm. To address dynamic behavior, we emulated the atmospheric disturbance produced by a wind flow of 8.3 m/s by controlling the rotational speed of the phase plates. Finally, we investigated how closely the atmospheric disturbance simulation emulated reality with an investigation of the measurements on the optical table. The verification confirmed that the simulator showed a Fried parameter of 87 ± 15 mm as designed, but a little slower wind velocity (7.5 ± 2.5 m/s) than expected. This was because of the nonlinear motion of the phase plates. In conclusion, we successfully mimicked the atmospheric disturbance of Bohyunsan Observatory with an error of less than 10% in terms of Fried parameter and wind velocity.

The effect of short-term creatine intake on blood lactic acid and muscle fatigue measured by accelerometer-based tremor response to acute resistance exercise

  • Lee, Sinwook;Hong, Gyuseog;Park, Wonil;Lee, Jaeseong;Kim, Nahyun;Park, Hyejoon;Park, Jonghoon
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.1
    • /
    • pp.29-36
    • /
    • 2020
  • [Purpose] The purpose of this study was to investigate the effects of short-term creatine intake on muscle fatigue induced by resistance exercise in healthy adolescent men, i.e., lactic acid concentration and wrist and head tremor measured by an accelerometer. [Methods] Twelve healthy adolescent men who had no experience with creatine intake were included. The subjects were randomly assigned to the creatine group and the placebo group, followed by 5 days of creatine and placebo intake, and 5 times of 5 sets of leg press, leg extension, bench press, and arm curl exercises at 70% repetition maximum (RM). The lactic acid concentration before and after exercising, rate of perceived exertion (RPE), and accelerometer-based wrist tremor and head tremor during exercise were measured. Subsequently, after 7 days to allow for creatine washout, the same exercise treatment and measurement were performed in each group after switching drug and placebo between the groups. [Results] The level of lactic acid before and after the acute resistance exercise trial was significantly lower in the creatine group than in the placebo group (P <0.05). The mean RPE during the resistance exercise was significantly lower in the creatine group than in the placebo group (P <0.05). There was no difference between the two groups in the mean wrist tremor during resistance exercise, but the mean head tremor values were significantly lower in the creatine group than in the placebo group in the arm curl, the last event of the exercise trials (P <0.05). [Conclusion] Short-term creatine intake reduces the blood fatigue factor increased by resistance exercise, and is thought to suppress fatigue, especially in the latter half of resistance exercise. Therefore, these findings indicate that short-term creatine intake can have an improved effect on anaerobic exercise performance.

A Study on the Design Development of S.I.(Space Identity) for Culturre and Tourism Market Development: Based on Jecheon Central Market (문화관광형시장 육성을 위한 S.I.(Space identity)개발연구: 제천중앙시장을 중심으로)

  • Jin-Soo, Park
    • Journal of Industrial Convergence
    • /
    • v.20 no.11
    • /
    • pp.197-203
    • /
    • 2022
  • The purpose of this study is to establish an S.I. (Space Identity) considering the spatial location and cultural specificity of Jecheon Jungang Market, the oldest and largest market in Jecheon with historical characteristics. To this end, we identify the flow of the cultural tourism market, investigate and analyze the current state of Jecheon Central Market, and present a direction based on storytelling for each space. The concept of space design was divided into space, time, people, and culture as coexistence, and merchants, products, and shopping malls share temporality and coexist in one space. Therefore, the facilities for each floor consisted of a gate, information board, lighting, rest area, design bench facility, information center, business compliance line, floor sign, and gate floor sign for each floor. Through this, it is necessary to establish a mid- to long-term development strategy by establishing a step-by-step promotion strategy to predict the economic effect of creating new demand and increasing sales in Jecheon Central Market.

Effect of Reaction Temperature Program on Thermal Degradation of Low-quality Pyrolytic Oil for Bench-scale Continuous Reaction System (벤치 규모 연속반응시스템에서 저급 열분해유 분해반응에 대한 반응온도 프로그램의 영향)

  • Lee, Kyong-Hwan;Nam, Ki-Yun
    • Clean Technology
    • /
    • v.15 no.3
    • /
    • pp.186-193
    • /
    • 2009
  • The characteristics of product materials obtained from thermal degradation of low-qualify pyrolytic oil were investigated in this study. The reactants were produced by pyrolysis of mixed plastic waste with film type in a commercial rotary kiln reaction system. The properties of reactants were measured by elemental analysis, calorimetry analysis and SIMDIST analyst. The result of degradation experiments with different reaction temperature programs was discussed through product yields, cumulative yields and production rates of oil products. The multi-step reaction temperature program resulted in higher yields of product oils and lower yields of residues than one-step reaction temperature program. The product characteristics such as production yield and the rate of oil products etc. were influenced by reaction temperature program in the continuous thermal degradation.

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.